Panasonic’s SP Series Polarized Power Relays feature a high switching capacity of 15A 250VAC (2 Form C) and 10A 250VAC (4 Form C). These Relays have a small, slim form factor that minimizes the use of board space. The SP Series Relays use a high-efficiency polarized electromagnetic mechanism to achieve high sensitivity, high reliability, and long life with strong resistance to shock and vibration.

The SP Series is also available with terminal socket options for DIN rail mounting.

Features and Benefits

  • Compact With High Reliability And Sensitivity
  • 2 Form C or 4 Form C Contact Arrangement
  • Excellent Shock And Vibration Resistance
  • Latching Types Available
  • Terminal Socket Options
  • RoHS / REACH Compliant
  • UL/C-UL, CSA, TUV Approved

Applications

  • Telecommunications
  • Alarm Equipment
  • Measurement
  • Power Control
Series image for SP Series Relays

SP Series Relays

Part number list

Results 24
Models table for series SP Series Relays
Part No.DatasheetOperating Function Terminal TypeRated Coil VoltageContact ArrangementProtective ConstructionAccessoriesPacking Quantity; Inner Carton (Pcs.) Packing Quantity; Outer Carton (Pcs.)Operate Voltage (@20oC)Release Voltage (at20°C) Rated Operating Current [±10%] (at 20°C)Resistance [±10%] (at 20°C) Rated Operating Power Max. Allowable Voltage (at 20°C 68°F)Contact ShapeContact Resistance (Initial)Contact MaterialContact Rating (Resistive Load)Max. Switching Power (Resistive Load) Max. Switching VoltageMax. Switching CurrentMin. Switching Load (Reference Value) Insulation Resistance (Initial)Dielectric Strength (Initial): Between Open ContactsDielectric Strength (Initial): Between Contact SetsDielectric Strength (Initial): Between Contact and CoilOperate Time (Initial) (At 20oC)Release Time (Initial) (at 20°C) Hock Resistance (Functional)Hock Resistance (Destructive)Vibration Resistance (Functional) Vibration Resistance (Destructive)Mechanical LifeConditionsWeight (Typ.)Resistive LoadSet Voltage Reset VoltageTime (Initial) (at 20°C 68°F) (Initial) Reset Time (Initial) (at20°C 68°F)
Single side stable
Plug-in terminal
6 V DC
2 Form C
Dust Cover
Terminal and mounting board are available.
20
200
Max. 70% V of rated coil voltage (Initial)
Min. 10% V of rated coil voltage (Initial)
50 mA
120 Ω
300 mW
150% V of rated coil voltage
Twin
Max. 30 mΩ (by voltage drop 6 V DC 1 A)
Stationary contact: Au flashed AgSnO2 type
Movable contact: AgSnO2 type
15 A 250 V AC, 10 A 30 V DC
3,750 VA, 300 W
250 V AC, 30 V DC (48 V DC: Max. 2 A)
15 A (AC), 10 A (DC)
100 mA 5 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,500 Vrms for 1 min (detection current: 10 mA)
3,000 Vrms for 1 min (detection current: 10 mA)
3,000 Vrms for 1 min (detection current: 10 mA)
Max. 50 ms at rated coil voltage (without bounce)
Max. 20 ms at rated coil voltage (without bounce, without diode)
392 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs)
980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 3 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 3 mm)
Min. 50x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -50 to +60℃
Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 50 g
[switching frequency: at 20 times/min]
Min. 100x103 ope. 15 A 250 V AC
Min. 100x103 ope. 10 A 30 V DC
Single side stable
Plug-in terminal
48 V DC
2 Form C
Dust Cover
Terminal and mounting board are available.
20
200
Max. 70% V of rated coil voltage (Initial)
Min. 10% V of rated coil voltage (Initial)
6.2 mA
7,700 Ω
300 mW
150% V of rated coil voltage
Twin
Max. 30 mΩ (by voltage drop 6 V DC 1 A)
Stationary contact: Au flashed AgSnO2 type
Movable contact: AgSnO2 type
15 A 250 V AC, 10 A 30 V DC
3,750 VA, 300 W
250 V AC, 30 V DC (48 V DC: Max. 2 A)
15 A (AC), 10 A (DC)
100 mA 5 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,500 Vrms for 1 min (detection current: 10 mA)
3,000 Vrms for 1 min (detection current: 10 mA)
3,000 Vrms for 1 min (detection current: 10 mA)
Max. 50 ms at rated coil voltage (without bounce)
Max. 20 ms at rated coil voltage (without bounce, without diode)
392 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs)
980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 3 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 3 mm)
Min. 50x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -50 to +60℃
Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 50 g
[switching frequency: at 20 times/min]
Min. 100x103 ope. 15 A 250 V AC
Min. 100x103 ope. 10 A 30 V DC
Single side stable
Plug-in terminal
12 V DC
2 Form C
Dust Cover
Terminal and mounting board are available.
20
200
Max. 70% V of rated coil voltage (Initial)
Min. 10% V of rated coil voltage (Initial)
25 mA
480 Ω
300 mW
150% V of rated coil voltage
Twin
Max. 30 mΩ (by voltage drop 6 V DC 1 A)
Stationary contact: Au flashed AgSnO2 type
Movable contact: AgSnO2 type
15 A 250 V AC, 10 A 30 V DC
3,750 VA, 300 W
250 V AC, 30 V DC (48 V DC: Max. 2 A)
15 A (AC), 10 A (DC)
100 mA 5 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,500 Vrms for 1 min (detection current: 10 mA)
3,000 Vrms for 1 min (detection current: 10 mA)
3,000 Vrms for 1 min (detection current: 10 mA)
Max. 50 ms at rated coil voltage (without bounce)
Max. 20 ms at rated coil voltage (without bounce, without diode)
392 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs)
980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 3 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 3 mm)
Min. 50x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -50 to +60℃
Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 50 g
[switching frequency: at 20 times/min]
Min. 100x103 ope. 15 A 250 V AC
Min. 100x103 ope. 10 A 30 V DC
2 coil latching
Plug-in terminal
24 V DC
4 Form C
Dust Cover
Terminal and mounting board are available.
10
100
Set coil: 12.5 mA
Reset coil: 12.5 mA
Set coil: 1,920 Ω
Reset coil: 1,920 Ω
300 mW
150% V of rated coil voltage
Twin
Max. 30 mΩ (by voltage drop 6 V DC 1 A)
Stationary contact: Au flashed AgSnO2 type
Movable contact: AgSnO2 type
10 A 250 V AC, 10 A 30 V DC
2,500 VA, 300 W
250 V AC, 30 V DC (48 V DC: Max. 2 A)
10 A
100 mA 5 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,500 Vrms for 1 min (detection current: 10 mA)
3,000 Vrms for 1 min (detection current: 10 mA)
3,000 Vrms for 1 min (detection current: 10 mA)
392 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs)
980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 3 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 3 mm)
Min. 50x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -50 to +60℃
Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 65 g
[switching frequency: at 20 times/min]
Min. 100x103 ope. 10 A 250 V AC
Min. 100x103 ope. 10 A 30 V DC
Max. 70% V of rated coil voltage (Initial)
Max. 70% V of rated coil voltage (Initial)
Max. 50 ms at rated coil voltage (without bounce)
Max. 50 ms at rated coil voltage (without bounce, without diode)
2 coil latching
Plug-in terminal
12 V DC
4 Form C
Dust Cover
Terminal and mounting board are available.
10
100
Set coil: 25 mA
Reset coil: 25 mA
Set coil: 480 Ω
Reset coil: 480 Ω
300 mW
150% V of rated coil voltage
Twin
Max. 30 mΩ (by voltage drop 6 V DC 1 A)
Stationary contact: Au flashed AgSnO2 type
Movable contact: AgSnO2 type
10 A 250 V AC, 10 A 30 V DC
2,500 VA, 300 W
250 V AC, 30 V DC (48 V DC: Max. 2 A)
10 A
100 mA 5 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,500 Vrms for 1 min (detection current: 10 mA)
3,000 Vrms for 1 min (detection current: 10 mA)
3,000 Vrms for 1 min (detection current: 10 mA)
392 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs)
980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 3 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 3 mm)
Min. 50x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -50 to +60℃
Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 65 g
[switching frequency: at 20 times/min]
Min. 100x103 ope. 10 A 250 V AC
Min. 100x103 ope. 10 A 30 V DC
Max. 70% V of rated coil voltage (Initial)
Max. 70% V of rated coil voltage (Initial)
Max. 50 ms at rated coil voltage (without bounce)
Max. 50 ms at rated coil voltage (without bounce, without diode)
2 coil latching
Plug-in terminal
6 V DC
4 Form C
Dust Cover
Terminal and mounting board are available.
10
100
Set coil: 50 mA
Reset coil: 50 mA
Set coil: 120 Ω
Reset coil: 120 Ω
300 mW
150% V of rated coil voltage
Twin
Max. 30 mΩ (by voltage drop 6 V DC 1 A)
Stationary contact: Au flashed AgSnO2 type
Movable contact: AgSnO2 type
10 A 250 V AC, 10 A 30 V DC
2,500 VA, 300 W
250 V AC, 30 V DC (48 V DC: Max. 2 A)
10 A
100 mA 5 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,500 Vrms for 1 min (detection current: 10 mA)
3,000 Vrms for 1 min (detection current: 10 mA)
3,000 Vrms for 1 min (detection current: 10 mA)
392 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs)
980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 3 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 3 mm)
Min. 50x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -50 to +60℃
Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 65 g
[switching frequency: at 20 times/min]
Min. 100x103 ope. 10 A 250 V AC
Min. 100x103 ope. 10 A 30 V DC
Max. 70% V of rated coil voltage (Initial)
Max. 70% V of rated coil voltage (Initial)
Max. 50 ms at rated coil voltage (without bounce)
Max. 50 ms at rated coil voltage (without bounce, without diode)
2 coil latching
Plug-in terminal
12 V DC
2 Form C
Dust Cover
Terminal and mounting board are available.
20
200
Set coil: 25 mA
Reset coil: 25 mA
Set coil: 480 Ω
Reset coil: 480 Ω
300 mW
150% V of rated coil voltage
Twin
Max. 30 mΩ (by voltage drop 6 V DC 1 A)
Stationary contact: Au flashed AgSnO2 type
Movable contact: AgSnO2 type
15 A 250 V AC, 10 A 30 V DC
3,750 VA, 300 W
250 V AC, 30 V DC (48 V DC: Max. 2 A)
15 A (AC), 10 A (DC)
100 mA 5 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,500 Vrms for 1 min (detection current: 10 mA)
3,000 Vrms for 1 min (detection current: 10 mA)
3,000 Vrms for 1 min (detection current: 10 mA)
392 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs)
980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 3 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 3 mm)
Min. 50x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -50 to +60℃
Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 50 g
[switching frequency: at 20 times/min]
Min. 100x103 ope. 15 A 250 V AC
Min. 100x103 ope. 10 A 30 V DC
Max. 70% V of rated coil voltage (Initial)
Max. 70% V of rated coil voltage (Initial)
Max. 50 ms at rated coil voltage (without bounce)
Max. 50 ms at rated coil voltage (without bounce, without diode)
2 coil latching
Plug-in terminal
5 V DC
2 Form C
Dust Cover
Terminal and mounting board are available.
20
200
Set coil: 40 mA
Reset coil: 40 mA
Set coil: 83 Ω
Reset coil: 83 Ω
300 mW
150% V of rated coil voltage
Twin
Max. 30 mΩ (by voltage drop 6 V DC 1 A)
Stationary contact: Au flashed AgSnO2 type
Movable contact: AgSnO2 type
15 A 250 V AC, 10 A 30 V DC
3,750 VA, 300 W
250 V AC, 30 V DC (48 V DC: Max. 2 A)
15 A (AC), 10 A (DC)
100 mA 5 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,500 Vrms for 1 min (detection current: 10 mA)
3,000 Vrms for 1 min (detection current: 10 mA)
3,000 Vrms for 1 min (detection current: 10 mA)
392 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs)
980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 3 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 3 mm)
Min. 50x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -50 to +60℃
Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 50 g
[switching frequency: at 20 times/min]
Min. 100x103 ope. 15 A 250 V AC
Min. 100x103 ope. 10 A 30 V DC
Max. 70% V of rated coil voltage (Initial)
Max. 70% V of rated coil voltage (Initial)
Max. 50 ms at rated coil voltage (without bounce)
Max. 50 ms at rated coil voltage (without bounce, without diode)
Single side stable
Plug-in terminal
3 V DC
2 Form C
Dust Cover
Terminal and mounting board are available.
20
200
Max. 70% V of rated coil voltage (Initial)
Min. 10% V of rated coil voltage (Initial)
100 mA
30 Ω
300 mW
150% V of rated coil voltage
Twin
Max. 30 mΩ (by voltage drop 6 V DC 1 A)
Stationary contact: Au flashed AgSnO2 type
Movable contact: AgSnO2 type
15 A 250 V AC, 10 A 30 V DC
3,750 VA, 300 W
250 V AC, 30 V DC (48 V DC: Max. 2 A)
15 A (AC), 10 A (DC)
100 mA 5 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,500 Vrms for 1 min (detection current: 10 mA)
3,000 Vrms for 1 min (detection current: 10 mA)
3,000 Vrms for 1 min (detection current: 10 mA)
Max. 50 ms at rated coil voltage (without bounce)
Max. 20 ms at rated coil voltage (without bounce, without diode)
392 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs)
980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 3 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 3 mm)
Min. 50x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -50 to +60℃
Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 50 g
[switching frequency: at 20 times/min]
Min. 100x103 ope. 15 A 250 V AC
Min. 100x103 ope. 10 A 30 V DC
Single side stable
Plug-in terminal
6 V DC
4 Form C
Dust Cover
Terminal and mounting board are available.
10
100
Max. 70% V of rated coil voltage (Initial)
Min. 10% V of rated coil voltage (Initial)
50 mA
120 Ω
300 mW
150% V of rated coil voltage
Twin
Max. 30 mΩ (by voltage drop 6 V DC 1 A)
Stationary contact: Au flashed AgSnO2 type
Movable contact: AgSnO2 type
10 A 250 V AC, 10 A 30 V DC
2,500 VA, 300 W
250 V AC, 30 V DC (48 V DC: Max. 2 A)
10 A
100 mA 5 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
1,500 Vrms for 1 min (detection current: 10 mA)
3,000 Vrms for 1 min (detection current: 10 mA)
3,000 Vrms for 1 min (detection current: 10 mA)
Max. 50 ms at rated coil voltage (without bounce)
Max. 20 ms at rated coil voltage (without bounce, without diode)
392 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs)
980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 3 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 3 mm)
Min. 50x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -50 to +60℃
Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 65 g
[switching frequency: at 20 times/min]
Min. 100x103 ope. 10 A 250 V AC
Min. 100x103 ope. 10 A 30 V DC
Latest Videos

Playlist

Thumbnail for Panasonic Industrial Solutions for 5G Networking Applications

Panasonic Industrial Solutions for 5G Networking Applications

Thumbnail for New Product Spotlight: DW Series Relays

New Product Spotlight: DW Series Relays

Thumbnail for New Product Spotlight: PA-N Series General Power Relays

New Product Spotlight: PA-N Series General Power Relays

Thumbnail for New Product Introduction: HE-R Series General Power Relays

New Product Introduction: HE-R Series General Power Relays

Thumbnail for New Product Introduction: HE Series Power Relay PV Type 90A Wide Gap

New Product Introduction: HE Series Power Relay PV Type 90A Wide Gap