Specifications
| Item | Performance characteristics |
|---|---|
| Operating Function | 2 coil latching |
| Terminal Type | Plug-in terminal |
| Rated Coil Voltage | 6 V DC |
| Contact Arrangement | 4 Form C |
| Protective Construction | Dust Cover |
| Accessories | Terminal and mounting board are available. |
| Packing Quantity; Inner Carton (Pcs.) | 10 |
| Packing Quantity; Outer Carton (Pcs.) | 100 |
| Rated Operating Current [±10%] (at 20°C) | Set coil: 50 mA Reset coil: 50 mA |
| Resistance [±10%] (at 20°C) | Set coil: 120 Ω Reset coil: 120 Ω |
| Rated Operating Power | 300 mW |
| Max. Allowable Voltage (at 20°C 68°F) | 150% V of rated coil voltage |
| Contact Shape | Twin |
| Contact Resistance (Initial) | Max. 30 mΩ (by voltage drop 6 V DC 1 A) |
| Contact Material | Stationary contact: Au flashed AgSnO2 type Movable contact: AgSnO2 type |
| Contact Rating (Resistive Load) | 10 A 250 V AC, 10 A 30 V DC |
| Max. Switching Power (Resistive Load) | 2,500 VA, 300 W |
| Max. Switching Voltage | 250 V AC, 30 V DC (48 V DC: Max. 2 A) |
| Max. Switching Current | 10 A |
| Min. Switching Load (Reference Value) | 100 mA 5 V DC |
| Insulation Resistance (Initial) | Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) |
| Dielectric Strength (Initial): Between Open Contacts | 1,500 Vrms for 1 min (detection current: 10 mA) |
| Dielectric Strength (Initial): Between Contact Sets | 3,000 Vrms for 1 min (detection current: 10 mA) |
| Dielectric Strength (Initial): Between Contact and Coil | 3,000 Vrms for 1 min (detection current: 10 mA) |
| Hock Resistance (Functional) | 392 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs) |
| Hock Resistance (Destructive) | 980 m/s2 (half-sine shock pulse: 6 ms) |
| Vibration Resistance (Functional) | 10 to 55 Hz (at double amplitude of 3 mm, detection time: 10 μs) |
| Vibration Resistance (Destructive) | 10 to 55 Hz (at double amplitude of 3 mm) |
| Mechanical Life | Min. 50x106 ope. (switching frequency: at 180 times/min) |
| Conditions | Ambient temperature: -50 to +60℃ Humidity: 5 to 85% RH (Avoid icing and condensation) |
| Weight (Typ.) | Approx. 65 g |
| Resistive Load | [switching frequency: at 20 times/min] Min. 100x103 ope. 10 A 250 V AC Min. 100x103 ope. 10 A 30 V DC |
| Set Voltage | Max. 70% V of rated coil voltage (Initial) |
| Reset Voltage | Max. 70% V of rated coil voltage (Initial) |
| Time (Initial) (at 20°C 68°F) (Initial) | Max. 50 ms at rated coil voltage (without bounce) |
| Reset Time (Initial) (at20°C 68°F) | Max. 50 ms at rated coil voltage (without bounce, without diode) |
Stock check