Specifications

Specifications table for model DK1a-L2-12V-F
ItemPerformance characteristics
Operating Function 2 coil latching
Rated Coil Voltage12 V DC
Contact Arrangement1 Form A
Protective ConstructionSealed
Terminal TypePC board terminal
AccessoriesSockets are available.
Packing Quantity; Inner Carton (Pcs.) 50
Packing Quantity; Outer Carton (Pcs.)500
Rated Operating Current [±10%] (at 20°C)Set coil: 16.6 mA
Reset coil: 16.6 mA
Resistance [±10%] (at 20°C) Set coil: 720 Ω
Reset coil: 720 Ω
Rated Operating Power 200 mW
Max. Allowable Voltage (at 20°C 68°F)130% V of rated coil voltage
Contact ShapeSingle
Contact Resistance (Initial)Max. 30 mΩ (by voltage drop 6 V DC 1 A)
Contact MaterialAu-flashed AgSnO2 type
Contact Rating (Resistive Load)10 A 250 V AC, 10 A 30 V DC
Max. Switching Power (Resistive Load) 2,500 VA (AC), 300 W (DC)
Max. Switching Voltage250 V AC, 125 V DC (0.2 A)
Max. Switching Current10 A (AC, DC)
Min. Switching Load (Reference Value) 10 mA 5 V DC
Insulation Resistance (Initial)Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
Dielectric Strength (Initial): Between Open Contacts1,000 Vrms for 1 min (detection current: 10 mA)
Dielectric Strength (Initial): Between Contact and Coil4,000 Vrms for 1 min (detection current: 10 mA)
Surge Withstand Voltage (Initial): Between Contact and Coil10,000 V
Hock Resistance (Functional)98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs)
Hock Resistance (Destructive)980 m/s2 (half-sine shock pulse: 6 ms)
Vibration Resistance (Functional)10 to 55 Hz (at double amplitude of 1.5 mm, detection time: 10 μs)
Vibration Resistance (Destructive)10 to 55 Hz (at double amplitude of 3 mm)
Mechanical LifeMin. 50x106 ope. (switching frequency: at 300 times/min)
ConditionsAmbient temperature: -40 to +65℃
Humidity: 5 to 85% RH (Avoid icing and condensation)
Weight (Typ.)Approx. 5 g
Resistive LoadPlease contact our sales representative.
Set Voltage Max. 70% V of rated coil voltage (Initial)
Reset VoltageMax. 70% V of rated coil voltage (Initial)
Time (Initial) (at 20°C 68°F) (Initial) Max. 10 ms at rated coil voltage (without bounce)
Reset Time (Initial) (at20°C 68°F) Max. 10 ms at rated coil voltage (without bounce, without diode)

Stock check

Model image for DK1a-L2-12V-F

DK1a-L2-12V-F

Latest Videos

Playlist

Thumbnail for Why Should A Relay Meet The New NEMA 410 Standard? (S1 E1)

Why Should A Relay Meet The New NEMA 410 Standard? (S1 E1)

Thumbnail for Smart Grid Products: LF-G Series Power Relays

Smart Grid Products: LF-G Series Power Relays

Thumbnail for Smart Grid Products: HE-V Series Power Relays

Smart Grid Products: HE-V Series Power Relays

Thumbnail for Features and Benefits of PhotoMOS®

Features and Benefits of PhotoMOS®

Thumbnail for Introduction to PhotoMOS®

Introduction to PhotoMOS®

Thumbnail for Where Technology Meets Humanity

Where Technology Meets Humanity

Thumbnail for Panasonic Industrial Solutions for 5G Networking Applications

Panasonic Industrial Solutions for 5G Networking Applications

Thumbnail for New Product Spotlight: DW Series Relays

New Product Spotlight: DW Series Relays

Thumbnail for New Product Spotlight: PhotoMOS® HE 1 Form A and HE SOP 1 Form A Series Relays

New Product Spotlight: PhotoMOS® HE 1 Form A and HE SOP 1 Form A Series Relays

Thumbnail for New Product Spotlight: PA-N Series General Power Relays

New Product Spotlight: PA-N Series General Power Relays