Specifications

Specifications table for model ADW1224HLW
ItemPerformance characteristics
Operating Function 2 coil latching
Contact TypeInrush type (16A, Inrush current 100A)
Type ClassificationLow profile type
Rated Coil Voltage24 V DC
Protective ConstructionFlux-resistant
Terminal TypePC board terminal
Packing Quantity; Inner Carton (Pcs.) 100
Packing Quantity; Outer Carton (Pcs.)500
Set Voltage Max. 80% V of rated coil voltage (Initial)
Reset VoltageMax. 80% V of rated coil voltage (Initial)
Rated Operating Current [±10%] (at 20°C)Set coil: 16.7 mA
Reset coil: 16.7 mA
Resistance [±10%] (at 20°C) Set coil: 1,440 Ω
Reset coil: 1,440 Ω
Rated Operating Power 400 mW
Max. Allowable Voltage (at 20°C 68°F)110% V of rated coil voltage
Contact Arrangement1 Form A
Contact ShapeSingle
Contact Resistance (Initial)Max. 100 mΩ (by voltage drop 6 V DC 1 A)
Contact MaterialAgSnO2 type
Contact Rating (Resistive Load)16 A 277 V AC
Max. Switching Power (Resistive Load) 4,432 VA
Max. Switching Voltage277 V AC
Max. Switching Current16 A (AC)
Min. Switching Load (Reference Value) 100 mA 5 V DC
Insulation Resistance (Initial)Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
Dielectric Strength (Initial): Between Open Contacts1,000 Vrms for 1 min (detection current: 10 mA)
Dielectric Strength (Initial): Between Contact and Coil5,000 Vrms for 1 min (detection current: 10 mA)
Surge Withstand Voltage (Initial): Between Contact and Coil12,000 V
Time (Initial) (at 20°C 68°F) (Initial) Max. 15 ms at rated coil voltage (without bounce)
Reset Time (Initial) (at20°C 68°F) Max. 15 ms at rated coil voltage (without bounce)
Hock Resistance (Functional)100 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs)
Hock Resistance (Destructive)1,000 m/s2 (half-sine shock pulse: 6 ms)
Vibration Resistance (Functional)10 to 55 Hz (at double amplitude of 2 mm, detection time: 10 μs)
Vibration Resistance (Destructive)10 to 55 Hz (at double amplitude of 3 mm)
Mechanical LifeMin. 106 ope. (switching frequency: at 180 times/min)
ConditionsAmbient temperature: -40 to +70℃ (Over 8A to 16A)
Ambient temperature: -40 to +85℃ (8A or less)
Humidity: 5 to 85% RH (Avoid icing and condensation)
Weight (Typ.)Approx. 7.5 g
Resistive LoadMin. 50x103 ope. 8 A 250 V AC (switching frequency: 20 times/min)
Min. 20x103 ope. 16 A 277 V AC (switching frequency ON : OFF = 1 s : 5 s)
Inrush Load; TungstenMin. 25x103 ope.
Inrush current: 100 A 600 W 120 V AC (switching frequency ON : OFF = 1 s : 59 s)
Packing QuantityCarton

Stock check

Model image for ADW1224HLW

ADW1224HLW

Latest Videos

Playlist

Thumbnail for Why Should A Relay Meet The New NEMA 410 Standard? (S1 E1)

Why Should A Relay Meet The New NEMA 410 Standard? (S1 E1)

Thumbnail for Smart Grid Products: LF-G Series Power Relays

Smart Grid Products: LF-G Series Power Relays

Thumbnail for Smart Grid Products: HE-V Series Power Relays

Smart Grid Products: HE-V Series Power Relays

Thumbnail for Features and Benefits of PhotoMOS®

Features and Benefits of PhotoMOS®

Thumbnail for Introduction to PhotoMOS®

Introduction to PhotoMOS®

Thumbnail for Where Technology Meets Humanity

Where Technology Meets Humanity

Thumbnail for Panasonic Industrial Solutions for 5G Networking Applications

Panasonic Industrial Solutions for 5G Networking Applications

Thumbnail for New Product Spotlight: DW Series Relays

New Product Spotlight: DW Series Relays

Thumbnail for New Product Spotlight: PhotoMOS® HE 1 Form A and HE SOP 1 Form A Series Relays

New Product Spotlight: PhotoMOS® HE 1 Form A and HE SOP 1 Form A Series Relays

Thumbnail for New Product Spotlight: PA-N Series General Power Relays

New Product Spotlight: PA-N Series General Power Relays