Specifications

Specifications table for model HE1aN-AC100V
ItemPerformance characteristics
Terminal TypePlug-in terminal
Coil TypeAC type (AC coil)
Rated Coil Voltage100/120 V AC
Rated Operating Power 1.9 VA to 2.7 VA
Contact Arrangement1 Form A
Protective ConstructionDust Cover
Operating Function Single side stable
AccessoriesTerminals are available.
Packing Quantity; Inner Carton (Pcs.) 20
Packing Quantity; Outer Carton (Pcs.)100
Operate Voltage (@20oC)Max. 70 V AC (Initial)
Release Voltage (at20°C) Min. 18 V AC (Initial)
Rated Operating Current [±10%] (at 20°C)18.7 to 22.1 mA
Max. Allowable Voltage 110% V of rated coil voltage (at 20℃)
Contact ShapeSingle
Contact Resistance (Initial)Max. 100 mΩ (by voltage drop 6 V DC 1 A)
Contact MaterialAgSnO2 type
Contact Rating (Resistive Load)30 A 277 V AC
Max. Switching Power (Resistive Load) 8,310 VA
Max. Switching Voltage277 V AC, 30 V DC
Max. Switching Current30 A (AC)
Min. Switching Load (Reference Value) 100 mA 5 V DC
Insulation Resistance (Initial)Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
Dielectric Strength (Initial): Between Open Contacts2,000 Vrms for 1 min (detection current: 10 mA)
Dielectric Strength (Initial): Between Contact and Coil5,000 Vrms for 1 min (detection current: 10 mA)
Surge Withstand Voltage (Initial): Between Contact and Coil10,000 V
Operate Time (Initial) (At 20oC)Max. 30 ms at rated coil voltage (without bounce)
Release Time (Initial) (at 20°C) Max. 30 ms at rated coil voltage (without bounce)
Hock Resistance (Functional)98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs)
Hock Resistance (Destructive)980 m/s2 (half-sine shock pulse: 6 ms)
Vibration Resistance (Functional)10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 μs)
Vibration Resistance (Destructive)10 to 55 Hz (at double amplitude of 1.5 mm)
Mechanical LifeMin. 5x106 ope. (switching frequency: at 180 times/min)
ConditionsAmbient temperature: -50 to +55℃
Humidity: 5 to 85% RH (Avoid icing and condensation)
Weight (Typ.)Approx. 90 g
Resistive Load[switching frequency: 20 times/min]
Min. 200x103 ope. 30 A 250 V AC
Packing QuantityCarton
Insulation DistanceMin. 8 mm
Contact GapMin. 3 mm (reference value)

Stock check

Model image for HE1aN-AC100V

HE1aN-AC100V

Resources

Filter by:
Showing 1 to 7 of 7 results
Results7
Latest Videos

Playlist

Thumbnail for Why Should A Relay Meet The New NEMA 410 Standard? (S1 E1)

Why Should A Relay Meet The New NEMA 410 Standard? (S1 E1)

Thumbnail for Smart Grid Products: LF-G Series Power Relays

Smart Grid Products: LF-G Series Power Relays

Thumbnail for Smart Grid Products: HE-V Series Power Relays

Smart Grid Products: HE-V Series Power Relays

Thumbnail for Features and Benefits of PhotoMOS®

Features and Benefits of PhotoMOS®

Thumbnail for Introduction to PhotoMOS®

Introduction to PhotoMOS®

Thumbnail for Where Technology Meets Humanity

Where Technology Meets Humanity

Thumbnail for Panasonic Industrial Solutions for 5G Networking Applications

Panasonic Industrial Solutions for 5G Networking Applications

Thumbnail for New Product Spotlight: DW Series Relays

New Product Spotlight: DW Series Relays

Thumbnail for New Product Spotlight: PhotoMOS® HE 1 Form A and HE SOP 1 Form A Series Relays

New Product Spotlight: PhotoMOS® HE 1 Form A and HE SOP 1 Form A Series Relays

Thumbnail for New Product Spotlight: PA-N Series General Power Relays

New Product Spotlight: PA-N Series General Power Relays