Specifications

Specifications table for model NC4EBD-DC24V
ItemPerformance characteristics
Protective ConstructionSealed
Terminal TypePlug-in terminal
Relay Shape Slim type
Rated Coil Voltage24 V DC
Rated Operating Power 720 mW
Contact Arrangement4 Form C
Operating Function Single side stable
AccessoriesSockets are available.
Packing Quantity; Inner Carton (Pcs.) 20
Packing Quantity; Outer Carton (Pcs.)200
Operate Voltage (@20oC)Max. 80% V of rated coil voltage (Initial)
Release Voltage (at20°C) Min. 10% V of rated coil voltage (Initial)
Rated Operating Current [±10%] (at 20°C)30 mA
Resistance [±10%] (at 20°C) 800 Ω
Max. Allowable Voltage 110% V of rated coil voltage (at 50℃)
Contact ShapeTwin
Contact Resistance (Initial)Max. 50 mΩ (by voltage drop 6 V DC 1 A)
Contact MaterialAu-clad AgNi type
Contact Rating (Resistive Load)2 A 250 V AC, 5 A 30 V DC
Max. Switching Power (Resistive Load) 500 VA, 150 W
Max. Switching Voltage250 V AC, 220 V DC
Max. Switching Current2 A (AC), 5 A (DC)
Min. Switching Load (Reference Value) 100 μA 1 V DC
Insulation Resistance (Initial)Min. 100 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
Dielectric Strength (Initial): Between Open Contacts1,000 Vrms for 1 min (detection current: 10 mA)
Dielectric Strength (Initial): Between Contact Sets1,000 Vrms for 1 min (detection current: 10 mA)
Dielectric Strength (Initial): Between Contact and Coil2,000 Vrms for 1 min (detection current: 10 mA)
Operate Time (Initial) (At 20oC)Max. 20 ms at rated coil voltage (without bounce)
Release Time (Initial) (at 20°C) Max. 10 ms at rated coil voltage (without bounce, without diode)
Hock Resistance (Functional)98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs)
Hock Resistance (Destructive)980 m/s2 (half-sine shock pulse: 6 ms)
Vibration Resistance (Functional)10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 μs)
Vibration Resistance (Destructive)10 to 55 Hz (at double amplitude of 2 mm)
Mechanical LifeMin. 50x106 ope. (switching frequency: at 180 times/min)
ConditionsAmbient temperature: -40 to +55℃
Humidity: 5 to 85% RH (Avoid icing and condensation)
Weight (Typ.)Approx. 19 g
Resistive Load[switching frequency: 20 times/min]
Min. 500x103 ope. 5 A 30 V DC
Min. 100x103 ope. 2 A 250 V AC

Stock check

Model image for NC4EBD-DC24V

NC4EBD-DC24V

Latest Videos

Playlist

Thumbnail for Why Should A Relay Meet The New NEMA 410 Standard? (S1 E1)

Why Should A Relay Meet The New NEMA 410 Standard? (S1 E1)

Thumbnail for Smart Grid Products: LF-G Series Power Relays

Smart Grid Products: LF-G Series Power Relays

Thumbnail for Smart Grid Products: HE-V Series Power Relays

Smart Grid Products: HE-V Series Power Relays

Thumbnail for Features and Benefits of PhotoMOS®

Features and Benefits of PhotoMOS®

Thumbnail for Introduction to PhotoMOS®

Introduction to PhotoMOS®

Thumbnail for Where Technology Meets Humanity

Where Technology Meets Humanity

Thumbnail for Panasonic Industrial Solutions for 5G Networking Applications

Panasonic Industrial Solutions for 5G Networking Applications

Thumbnail for New Product Spotlight: DW Series Relays

New Product Spotlight: DW Series Relays

Thumbnail for New Product Spotlight: PhotoMOS® HE 1 Form A and HE SOP 1 Form A Series Relays

New Product Spotlight: PhotoMOS® HE 1 Form A and HE SOP 1 Form A Series Relays

Thumbnail for New Product Spotlight: PA-N Series General Power Relays

New Product Spotlight: PA-N Series General Power Relays