Specifications

Specifications table for model AEV14024
ItemPerformance characteristics
Terminal TypeScrew terminal
Coil Terminal StructureConnector
Rated Coil Voltage24V DC
Contact Capacity120 A
Protective ConstructionCapsule contact
Operating Function Single side stable
Operate (Set) Voltage (at20°C) (Initial) Max. 18 V DC
Release (Reset) voltage (at20°C) (Initial)Min. 2 V DC
Rated Operating Current [±10%] (at 20°C)0.176 A
Coil Resistance (At 20oC)136Ω
Rated Operating Power (at 20°C) 4.2 W
Max. applied voltage32V DC
Contact Arrangement1 Form A
Contact MaterialCopper alloy
Nominal Switching Capacity (Resistive Load) 120A 450V DC (Carry, 38mm2 wire)
Max. Carring Current 120A Continuity
225A 3 min.
400A 30 sec. (38mm2 wire)
Min. Switching Load (Resistive) 1A 12V DC (at 20°C)
Contact Voltage Drop (Initial)Max. 0.03 V (by voltage drop 6 V DC 20 A)
Insulation Resistance (Min. MΩ)(Initial)Min. 100 MΩ (At 500 V DC, Measured portion is the same as the case of dielectric strength.)
Dielectric Strength (Between Open Contacts) (Initial)2,500 Vrms for 1min. (detection current: 10mA.)
Dielectric Strength (Between Contacts and Coil) (Initial)2,500 Vrms for 1min. (detection current: 10mA.)
Operate (Set) Time<br>(At Rated Coil Voltage) (At 20oC) (Initial)Max. 50 ms (without bounce)
Release (Reset) Time<br>(at Rated Coil Voltage) (at 20&deg;C) (Initial)Max. 30 ms (with no coil protective elements)
Shock Resistance: Functional For ON: Min. 196 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs)
For OFF: Min. 98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs)
Shock Resistance: DestructiveMin. 490 m/s2 (half-sine shock pulse: 6 ms)
Vibration Resistance: Functional10 to 200 Hz, 43 m/s2 (detection time: 10 µs)
Vibration Resistance: Destructive10 to 200 Hz, 43 m/s2 (Time of vibration for each direction; X, Y, Z direction: 4 hours)
Expected Life: Mechanical LifeMin. 2 x 105
Expected Life: Electrical Life (Resistive)30A 450V DC, Min. 1,000 operations
Expected Life: Switch-Off Life[Forward direction]:
1,200 A 300 V DC, Min. 1 cycle
120 A 450 V DC, Min. 50 operations
[Reverse direction]: -120 A 200 V DC, Min. 50 operations
Expected Life: Inrush Current (Capacitor)120 A 20 V DC, Min. 70,000 operations
ConditionsAmbient temperature: –40 to +80°C
Humidity: 5 to 85% R.H. (Avoid icing when using at temperatures lower than 0°C.)
Weight (Typ.)Approx. 400 g
Inner Carton (Pieces)1
Outer Carton (Pieces) 20
Usable Voltage Range20 V DC to 32 V DC

Stock check

AEV14024

Latest Videos

Playlist

Thumbnail for Why Should A Relay Meet The New NEMA 410 Standard? (S1 E1)

Why Should A Relay Meet The New NEMA 410 Standard? (S1 E1)

Thumbnail for Smart Grid Products: LF-G Series Power Relays

Smart Grid Products: LF-G Series Power Relays

Thumbnail for Smart Grid Products: HE-V Series Power Relays

Smart Grid Products: HE-V Series Power Relays

Thumbnail for Features and Benefits of PhotoMOS®

Features and Benefits of PhotoMOS®

Thumbnail for Introduction to PhotoMOS®

Introduction to PhotoMOS®

Thumbnail for Where Technology Meets Humanity

Where Technology Meets Humanity

Thumbnail for Panasonic Industrial Solutions for 5G Networking Applications

Panasonic Industrial Solutions for 5G Networking Applications

Thumbnail for New Product Spotlight: DW Series Relays

New Product Spotlight: DW Series Relays

Thumbnail for New Product Spotlight: PhotoMOS® HE 1 Form A and HE SOP 1 Form A Series Relays

New Product Spotlight: PhotoMOS® HE 1 Form A and HE SOP 1 Form A Series Relays

Thumbnail for New Product Spotlight: PA-N Series General Power Relays

New Product Spotlight: PA-N Series General Power Relays