Specifications

Specifications table for model ACTG2H4
ItemPerformance characteristics
Protective ConstructionSealed
Rated Coil Voltage12V DC
Coil Resistance (at 20oC)320Ω
Heat Resistance of TypesHigh heat-resistant type
Contact Arrangement1 Form C
Contact TypeStandard type
Terminal TypePC board type
Operating Function Single side stable
Operate (Set) Voltage (at20°C) (Initial) Max. 7.0V DC
Release (Reset) voltage (at20℃) (Initial)Min. 0.8V DC
Rated Operating Current [±10%] (at 20°C)37.5mA
Coil Resistance (At 20oC)320Ω
Rated Operating Power 450 mW
Usable Voltage Range10 to 16V DC
Contact Resistance (Initial)Max. 50mΩ (N.O. side: typ. 3mΩ, N.C. side: typ. 4mΩ) (By voltage drop 1A 6V DC)
Contact MaterialAg alloy
Nominal Switching Capacity (Resistive Load) N.O. side: 30A 14V DC, N.C. side: 15A 14V DC
Contact Data: Max. Carrying Current35A/ 1 hour (Coil applied voltage 12V DC, at 20°)
Min. Switching Load (Resistive) 1A 14V DC (at 20°C)
Insulation Resistance (Min. MΩ)(Initial)Min. 100 MΩ (at 500V DC, Measurement at same location as [Dielectric strength] section.)
Dielectric Strength (Between Open Contacts) (Initial)500 Vrms for 1 min (Detection current: 10mA)
Dielectric Strength (Between Contacts and Coil) (Initial)500 Vrms for 1 min (Detection current: 10mA)
Operate (Set) Time<br>(At Rated Coil Voltage) (At 20oC) (Initial)Max. 10ms (without contact bounce time)
Release (Reset) Time<br>(at Rated Coil Voltage) (at 20&deg;C) (Initial)Max. 10ms (without contact bounce time) (without protective element)
Shock Resistance: Functional Min. 100 m/s2 (Half-wave pulse of sine wave: 11ms; detection time: 10µs)
Shock Resistance: DestructiveMin. 1,000 m/s2
(Half-wave pulse of sine wave: 6ms, number of shocks for each direction: X, Y and Z direction: 3 times)
Vibration Resistance: Functional10 to 100 Hz, Min. 44.1 m/s2 (Detection time: 10µs)
Vibration Resistance: Destructive10 to 500 Hz, Min. 44.1 m/s2
Time of vibration for each direction; X, Y direction: 2 hours, Z direction: 4 hours
Expected Life: Mechanical LifeMin. 107 (at 120 times/min)
Expected Life: Electrical[Resistive load]
Min. 105 at rated switching capacity
Operating frequency: 1s ON, 9s OFF
[Motor load]
Min. 105 30A 14V DC at motor lock condition
Operating frequency: 0.5s ON, 9.5s OFF
[Lamp load]
Min. 18 x 104 at inrush 84A, steady 12A 14 V DC
Operating frequency: 1s ON, 14s OFF
ConditionsAmbient temperature: –40 to +110°C, Humidity: 2 to 85% RH
(Avoid icing and condensation)
Weight (Typ.)Approx. 12 g
Packing QuantityTube
Inner Carton (Pieces)40
Outer Carton (Pieces) 800

Stock check

Model image for ACTG2H4

ACTG2H4

Latest Videos

Playlist

Thumbnail for Why Should A Relay Meet The New NEMA 410 Standard? (S1 E1)

Why Should A Relay Meet The New NEMA 410 Standard? (S1 E1)

Thumbnail for Smart Grid Products: LF-G Series Power Relays

Smart Grid Products: LF-G Series Power Relays

Thumbnail for Smart Grid Products: HE-V Series Power Relays

Smart Grid Products: HE-V Series Power Relays

Thumbnail for Features and Benefits of PhotoMOS®

Features and Benefits of PhotoMOS®

Thumbnail for Introduction to PhotoMOS®

Introduction to PhotoMOS®

Thumbnail for Where Technology Meets Humanity

Where Technology Meets Humanity

Thumbnail for Panasonic Industrial Solutions for 5G Networking Applications

Panasonic Industrial Solutions for 5G Networking Applications

Thumbnail for New Product Spotlight: DW Series Relays

New Product Spotlight: DW Series Relays

Thumbnail for New Product Spotlight: PhotoMOS® HE 1 Form A and HE SOP 1 Form A Series Relays

New Product Spotlight: PhotoMOS® HE 1 Form A and HE SOP 1 Form A Series Relays

Thumbnail for New Product Spotlight: PA-N Series General Power Relays

New Product Spotlight: PA-N Series General Power Relays