Specifications

Specifications table for model AQY212FG2S
ItemPerformance characteristics
PackageSOP4
Load Voltage [ V<sub>L</sub> ] (V<sub>L</sub>)60 V
Continuous Load Current (I<sub>L</sub>)1.25 A
I/O Isolation Voltage (V<sub>iso</sub>)500 Vrms
Packing QuantityTube packing style
Product NameGU SOP 1 Form A High Capacity Voltage-sensitive
TypeGU
Voltage TypeAC/DC
Input Voltage (V<sub>IN</sub>)6 V
Input Reverse Voltage (V<sub>RIN</sub>)5 V
Power Dissipation (P<sub>in</sub>)65 mW
Peak Load Current (I<sub>peak</sub>)3 A
Power Dissipation (P<sub>out</sub>)400 mW
Total Power Dissipation (P<sub>t</sub>)450 mW
Ambient Temperature: Operating (T<sub>opr</sub>)-40 to +85°C
Ambient Temperature: Storage (T<sub>stg</sub>)-40 to +100°C
Operate Voltage (Typical) (V<sub>Fon</sub>)1.4 V
Operate Voltage (Maximum) (V<sub>Fon</sub>)4 V
Turn Off Voltage (Minimum) (V<sub>Foff</sub>)0.8 V
Turn Off Voltage (Typical) (V<sub>Foff</sub>)1.4 V
Input Current (Typical) (I<sub>IN</sub>)8.5 mA
On Resistance (Typical) (R<sub>on</sub>)0.2 ohm
On Resistance (Maximum) (R<sub>on</sub>)0.5 ohm
Off State Leakage Current (Maximum) (I<sub>Leak</sub>)1μA
Over Current ProtectionNothing
Turn On Time (Typical) 0.7 ms
Turn On Time (Maximum) 5 ms
Turn Off Time (Typical)0.1 ms
Turn Off Time (Maximum)0.5 ms
I/O Capacitance (Typical) (C<sub>iso</sub>)0.8 pF
I/O Capacitance (Maximum) (C<sub>iso</sub>)1.5 pF
Initial I/O Isolation Resistance (Minimum) (R<sub>iso</sub>)1,000 M ohm
Maximum Switching Frequency 5 cps
Input Voltage (V<sub>IN</sub>)Min.: 4.5 V, Max.: 5.5 V
Load Voltage (V<sub>L</sub>)Max.: 48 V
Continuous Load Current (I<sub>L</sub>)Max.: 1.25 A
Terminal TypeSurface-mount terminal
Contact Arrangement1 Form A
External Dimensions
Recommended Mounting Pad (Top View)
Load current1.25 A
Junction temperature (T<sub>j</sub>)125°C
Packing quantity<br>1-tube (pcs.)100
Packing quantity<br>Outer carton (pcs.)2,000

Stock check

Model image for AQY212FG2S

AQY212FG2S

Latest Videos

Playlist

Thumbnail for Why Should A Relay Meet The New NEMA 410 Standard? (S1 E1)

Why Should A Relay Meet The New NEMA 410 Standard? (S1 E1)

Thumbnail for Smart Grid Products: LF-G Series Power Relays

Smart Grid Products: LF-G Series Power Relays

Thumbnail for Smart Grid Products: HE-V Series Power Relays

Smart Grid Products: HE-V Series Power Relays

Thumbnail for Features and Benefits of PhotoMOS®

Features and Benefits of PhotoMOS®

Thumbnail for Introduction to PhotoMOS®

Introduction to PhotoMOS®

Thumbnail for Where Technology Meets Humanity

Where Technology Meets Humanity

Thumbnail for Panasonic Industrial Solutions for 5G Networking Applications

Panasonic Industrial Solutions for 5G Networking Applications

Thumbnail for New Product Spotlight: DW Series Relays

New Product Spotlight: DW Series Relays

Thumbnail for New Product Spotlight: PhotoMOS® HE 1 Form A and HE SOP 1 Form A Series Relays

New Product Spotlight: PhotoMOS® HE 1 Form A and HE SOP 1 Form A Series Relays

Thumbnail for New Product Spotlight: PA-N Series General Power Relays

New Product Spotlight: PA-N Series General Power Relays