Part No.sort descendingData SheetMax. operation distanceStable sensing rangeStandard sensing objectHysteresisSupply voltageCurrent consumptionOutputOutput:Short-circuit protectionMax. response frequencyOperation indicatorParts Inventory
   Column active Filter
Close

Filter by Max. operation distance

Column active Filter
Close

Filter by Stable sensing range

Column active Filter
Close

Filter by Standard sensing object

Column active Filter
Close

Filter by Hysteresis

Column active Filter
Close

Filter by Supply voltage

Column active Filter
Close

Filter by Current consumption

Column active Filter
Close

Filter by Output

Column active Filter
Close

Filter by Output:Short-circuit protection

Column active Filter
Close

Filter by Max. response frequency

Column active Filter
Close

Filter by Operation indicator

 
design engineersPanasonicGX-5SUB-C5
1.5 mm 0.059 in plus or minus 10 %
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 1.2 mm 0 to 0.047 in
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 6 × 6 × t 1 mm 0.236 × 0.236 × t 0.039 in20 % or less of operation distance (with standard sensing object)12 to 24 V DC +10 /-15 % Ripple P-P 10 % or less0.8 mA or less
(Note) It is the leakage current when the output is in the OFF state.
Non-contact DC 2-wire type
- Load current: 3 to 70 mA(Note 1)
- Residual voltage: 3 V or less(Note 2)
(Note 1) The maximum load current varies depending on the ambient temperature.
(Note 2) When the cable is extended, the residual voltage becomes larger.
Incorporated1.7 kHzOrange LED (lights up when the output is ON)
design engineersPanasonicGX-8MLU-C5
4 mm 0.157 in plus or minus 10 %
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 3.2 mm 0 to 0.126 in
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 20 × 20 × t 1 mm 0.787 × 0.787 × t 0.039 in20 % or less of operation distance (with standard sensing object)12 to 24 V DC +10 /-15 % Ripple P-P 10 % or less0.8 mA or less
(Note) It is the leakage current when the output is in the OFF state.
Non-contact DC 2-wire type
- Load current: 3 to 70 mA (Note 1)
- Residual voltage: 3 V or less (Note 2)
(Note 1) The maximum load current varies depending on the ambient temperature.
(Note 2) When the cable is extended, the residual voltage becomes larger.
Incorporated1 kHzNormally closed type: Orange LED (lights up when the output is ON)
design engineersPanasonicGX-8MLUB-C5
4 mm 0.157 in plus or minus 10 %
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 3.2 mm 0 to 0.126 in
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 20 × 20 × t 1 mm 0.787 × 0.787 × t 0.039 in20 % or less of operation distance (with standard sensing object)12 to 24 V DC +10 /-15 % Ripple P-P 10 % or less0.8 mA or less
(Note) It is the leakage current when the output is in the OFF state.
Non-contact DC 2-wire type
- Load current: 3 to 70 mA (Note 1)
- Residual voltage: 3 V or less (Note 2)
(Note 1) The maximum load current varies depending on the ambient temperature.
(Note 2) When the cable is extended, the residual voltage becomes larger.
Incorporated1 kHzOrange LED (lights up when the output is ON)
design engineersPanasonicGX-N12M-C5
3 mm 0.118 in plus or minus 10 %
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 2.4 mm 0 to 0.094 in
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 12 × 12 × t 1 mm 0.472 × 0.472 × t 0.039 in20 % or less of operation distance (with standard sensing object)12 to 24 V DC +10 /-15 % Ripple P-P 10 % or less10 mA or lessNPN open-collector transistor
- Maximum sink current: 100 mA
- Applied voltage: 30 V DC or less (between output and 0 V)
- Residual voltage: 1.5 V or less (at 100 mA sink current), 0.4 V or less (at 16 mA sink current)
Incorporated450 HzOrange LED (lights up when the output is ON)
design engineersPanasonicGX-N12MLB-C5
8 mm 0.315 in plus or minus 10 %
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 6.4 mm 0 to 0.252 in
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 30 × 30 × t 1 mm 1.181 × 1.181 × t 0.039 in20 % or less of operation distance (with standard sensing object)12 to 24 V DC +10 /-15 % Ripple P-P 10 % or less10 mA or lessNPN open-collector transistor
- Maximum sink current: 100 mA
- Applied voltage: 30 V DC or less (between output and 0 V)
- Residual voltage: 1.5 V or less (at 100 mA sink current), 0.4 V or less (at 16 mA sink current)
Incorporated350 HzOrange LED (lights up when the output is ON)
design engineersPanasonicGX-N18MB-C5
7 mm 0.276 in plus or minus 10 %
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 5.6 mm 0 to 0.220 in
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 18 × 18 × t 1 mm 0.709 × 0.709 × t 0.039 in20 % or less of operation distance (with standard sensing object)12 to 24 V DC +10 /-15 % Ripple P-P 10 % or less10 mA or lessNPN open-collector transistor
- Maximum sink current: 100 mA
- Applied voltage: 30 V DC or less (between output and 0 V)
- Residual voltage: 1.5 V or less (at 100 mA sink current), 0.4 V or less (at 16 mA sink current)
Incorporated300 HzOrange LED (lights up when the output is ON)
design engineersPanasonicGX-N18ML-C5
15 mm 0.591 in plus or minus 10 %
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 12 mm 0 to 0.472 in
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 50 × 50 × t 1 mm 1.969 × 1.969 × t 0.039 in20 % or less of operation distance (with standard sensing object)12 to 24 V DC +10 /-15 % Ripple P-P 10 % or less10 mA or lessNPN open-collector transistor
- Maximum sink current: 100 mA
- Applied voltage: 30 V DC or less (between output and 0 V)
- Residual voltage: 1.5 V or less (at 100 mA sink current), 0.4 V or less (at 16 mA sink current)
Incorporated100 HzOrange LED (lights up when the output is ON)
design engineersPanasonicGX-N18MLB-C5
15 mm 0.591 in plus or minus 10 %
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 12 mm 0 to 0.472 in
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 50 × 50 × t 1 mm 1.969 × 1.969 × t 0.039 in20 % or less of operation distance (with standard sensing object)12 to 24 V DC +10 /-15 % Ripple P-P 10 % or less10 mA or lessNPN open-collector transistor
- Maximum sink current: 100 mA
- Applied voltage: 30 V DC or less (between output and 0 V)
- Residual voltage: 1.5 V or less (at 100 mA sink current), 0.4 V or less (at 16 mA sink current)
Incorporated100 HzOrange LED (lights up when the output is ON)
design engineersPanasonicGX-N30MB-C5
10 mm 0.394 in plus or minus 10 %
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 8 mm 0 to 0.315 in
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 30 × 30 × t 1 mm 1.181 × 1.181 × t 0.039 in20 % or less of operation distance (with standard sensing object)12 to 24 V DC +10 /-15 % Ripple P-P 10 % or less10 mA or lessNPN open-collector transistor
- Maximum sink current: 100 mA
- Applied voltage: 30 V DC or less (between output and 0 V)
- Residual voltage: 1.5 V or less (at 100 mA sink current), 0.4 V or less (at 16 mA sink current)
Incorporated300 HzOrange LED (lights up when the output is ON)
design engineersPanasonicGX-N30ML-C5
22 mm 0.866 in plus or minus 10 %
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 17.6 mm 0 to 0.693 in
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 70 × 70 × t 1 mm 2.756 × 2.756 × t 0.039 in20 % or less of operation distance (with standard sensing object)12 to 24 V DC +10 /-15 % Ripple P-P 10 % or less10 mA or lessNPN open-collector transistor
- Maximum sink current: 100 mA
- Applied voltage: 30 V DC or less (between output and 0 V)
- Residual voltage: 1.5 V or less (at 100 mA sink current), 0.4 V or less (at 16 mA sink current)
Incorporated100 HzOrange LED (lights up when the output is ON)
design engineersPanasonicGX-N30MLB-C5
22 mm 0.866 in plus or minus 10 %
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 17.6 mm 0 to 0.693 in
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 70 × 70 × t 1 mm 2.756 × 2.756 × t 0.039 in20 % or less of operation distance (with standard sensing object)12 to 24 V DC +10 /-15 % Ripple P-P 10 % or less10 mA or lessNPN open-collector transistor
- Maximum sink current: 100 mA
- Applied voltage: 30 V DC or less (between output and 0 V)
- Residual voltage: 1.5 V or less (at 100 mA sink current), 0.4 V or less (at 16 mA sink current)
Incorporated100 HzOrange LED (lights up when the output is ON)
design engineersPanasonicGX-12MLU-C5
8 mm 0.315 in plus or minus 10 %
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 6.4 mm 0 to 0.252 in
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 30 × 30 × t 1 mm 1.181 × 1.181 × t 0.039 in20 % or less of operation distance (with standard sensing object)12 to 24 V DC +10 /-15 % Ripple P-P 10 % or less0.8 mA or less
(Note) It is the leakage current when the output is in the OFF state.
Non-contact DC 2-wire type
- Load current: 3 to 70 mA (Note 1)
- Residual voltage: 3 V or less (Note 2)
(Note 1) The maximum load current varies depending on the ambient temperature.
(Note 2) When the cable is extended, the residual voltage becomes larger.
Incorporated650 HzNormally closed type: Orange LED (lights up when the output is ON)
design engineersPanasonicGX-12MLUB-J
8 mm 0.315 in plus or minus 10 %
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 6.4 mm 0 to 0.252 in
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 30 × 30 × t 1 mm 1.181 × 1.181 × t 0.039 in20 % or less of operation distance (with standard sensing object)12 to 24 V DC +10 /-15 % Ripple P-P 10 % or less0.8 mA or less
(Note) It is the leakage current when the output is in the OFF state.
Non-contact DC 2-wire type
- Load current: 3 to 70 mA (Note 1)
- Residual voltage: 3 V or less (Note 2)
(Note 1) The maximum load current varies depending on the ambient temperature.
(Note 2) When the cable is extended, the residual voltage becomes larger.
Incorporated650 HzOrange LED (lights up when the output is ON)
design engineersPanasonicGX-12MU-J
3 mm 0.118 in plus or minus 10 %
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 2.4 mm 0 to 0.094 in
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 12 × 12 × t 1 mm 0.472 × 0.472 × t 0.039 in20 % or less of operation distance (with standard sensing object)12 to 24 V DC +10 /-15 % Ripple P-P 10 % or less0.8 mA or less
(Note) It is the leakage current when the output is in the OFF state.
Non-contact DC 2-wire type
- Load current: 3 to 70 mA (Note 1)
- Residual voltage: 3 V or less (Note 2)
(Note 1) The maximum load current varies depending on the ambient temperature.
(Note 2) When the cable is extended, the residual voltage becomes larger.
Incorporated1.2 kHzn/a
design engineersPanasonicGX-12MLU
8 mm 0.315 in plus or minus 10 %
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 6.4 mm 0 to 0.252 in
(Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 30 × 30 × t 1 mm 1.181 × 1.181 × t 0.039 in20 % or less of operation distance (with standard sensing object)12 to 24 V DC +10 /-15 % Ripple P-P 10 % or less0.8 mA or less
(Note) It is the leakage current when the output is in the OFF state.
Non-contact DC 2-wire type
- Load current: 3 to 70 mA (Note 1)
- Residual voltage: 3 V or less (Note 2)
(Note 1) The maximum load current varies depending on the ambient temperature.
(Note 2) When the cable is extended, the residual voltage becomes larger.
Incorporated650 HzNormally closed type: Orange LED (lights up when the output is ON)