Laser Measurement Sensors: Metal-sheet Double-feed Detector GD

Model List

Found 8 matches. Display 1 - 8 matches.
Part No.sort ascendingData SheetTypeApplicable controllerSensing range (between sensor heads)Detectable sheet thickness : Applicable controllers GD-C1/C2 : Setting distance 20 mm 0.787 inDetectable sheet thickness : Applicable controllers GD-C3 : Setting distance 20 mm 0.787 inDetectable sheet thickness : Applicable controllers GD-C1/C2 : Setting distance 30 mm 1.181 inDetectable sheet thickness : Applicable controllers GD-C3 : Setting distance 30 mm 1.181 inEnvironmental resistance : ProtectionEnvironmental resistance : Ambient temperatureEnvironmental resistance : Ambient humidityParts Inventory
   Column active Filter
Close

Filter by Type

Column active Filter
Close

Filter by Applicable controller

Column active Filter
Close

Filter by Sensing range (between sensor heads)

Column active Filter
Close

Filter by Detectable sheet thickness : Applicable controllers GD-C1/C2 : Setting distance 20 mm 0.787 in

Column active Filter
Close

Filter by Detectable sheet thickness : Applicable controllers GD-C3 : Setting distance 20 mm 0.787 in

Column active Filter
Close

Filter by Detectable sheet thickness : Applicable controllers GD-C1/C2 : Setting distance 30 mm 1.181 in

Column active Filter
Close

Filter by Detectable sheet thickness : Applicable controllers GD-C3 : Setting distance 30 mm 1.181 in

Column active Filter
Close

Filter by Environmental resistance : Protection

Column active Filter
Close

Filter by Environmental resistance : Ambient temperature

Column active Filter
Close

Filter by Environmental resistance : Ambient humidity

 
design engineersPanasonicGD-C3
Small object detectionn/an/an/an/an/an/an/a-10 to +50 ℃ +14 to +122 ℉ (No dew condensation or icing allowed), Storage: -25 to +70 C° -13 to +158 ℉45 to 85 % RH, Storage: 35 to 90 % RH
design engineersPanasonicGD-C2
With RS-232C communication functionn/an/an/an/an/an/an/a-10 to +50 ℃ +14 to +122 ℉ (No dew condensation or icing allowed), Storage: -25 to +70 C° -13 to +158 ℉45 to 85 % RH, Storage: 35 to 90 % RH
design engineersPanasonicGD-C1
Standardn/an/an/an/an/an/an/a-10 to +50 ℃ +14 to +122 ℉ (No dew condensation or icing allowed), Storage: -25 to +70 C° -13 to +158 ℉45 to 85 % RH, Storage: 35 to 90 % RH
design engineersPanasonicGD-3
Small object detectionGD-C310 mm 0.394 in or lessn/an/an/an/aIP67 (IEC)-10 to +60 degrees +14 to +140 degrees Fahrenheit , Storage: -25 to +70 degrees -13 to +158 degrees Fahrenheit45 to 85 % RH, Storage: 35 to 95 % RH
design engineersPanasonicGD-20-C20
Long sensing rangeGD-C1, GD-C270 mm 2.756 in or lessn/an/an/an/aIP67 (IEC), IP67G-10 to +60 degrees +14 to +140 degrees Fahrenheit , Storage: -25 to +70 degrees -13 to +158 degrees Fahrenheit45 to 85 % RH, Storage: 35 to 95 % RH
design engineersPanasonicGD-20-C10
Long sensing rangeGD-C1, GD-C270 mm 2.756 in or lessn/an/an/an/aIP67 (IEC), IP67G-10 to +60 degrees +14 to +140 degrees Fahrenheit , Storage: -25 to +70 degrees -13 to +158 degrees Fahrenheit45 to 85 % RH, Storage: 35 to 95 % RH
design engineersPanasonicGD-20
Long sensing rangeGD-C1, GD-C270 mm 2.756 in or lessn/an/an/an/aIP67 (IEC), IP67G-10 to +60 degrees +14 to +140 degrees Fahrenheit , Storage: -25 to +70 degrees -13 to +158 degrees Fahrenheit45 to 85 % RH, Storage: 35 to 95 % RH
design engineersPanasonicGD-10
High precisionGD-C1, GD-C2, GD-C330 mm 1.181 in or lessStandard sensing object size: 80 x 80 mm 3.150 x 3.150 in
Iron(SPCC): 0.07 to 1 mm 0.003 to 0.039 in
Aluminum: 0.03 to 6 mm 0.001 to 0.236 in
Copper: 0.03 to 6 mm 0.001 to 0.236 in
Brass: 0.03 to 6 mm 0.001 to 0.236 in
Stainless steel (SUS304): 0.1 to 6 mm 0.004 to 0.236 in
(Note) The above detectable sheet thicknesses are typical data at the given sensing distance. The allowable thickness will differ from the range described in the above table at other setting distances. Further, double feeds of aluminum foils can also be detected at distances shorter than the above. Please contact our office for details.
Standard sensing object size: 80 x 80 mm 3.150 x 3.150 in
Iron(SPCC): 0.01 to 0.3 mm 0.0004 to 0.012 in
Aluminum: 0.015 to 1 mm 0.001 to 0.039 in
Copper: 0.018 to 1 mm 0.001 to 0.039 in
Brass: 0.01 to 1 mm 0.0004 to 0.039 in
Stainless steel (SUS304): 0.05 to 2 mm 0.002 to 0.079 in
(Note) The above detectable sheet thicknesses are typical data at the given sensing distance. The allowable thickness will differ from the range described in the above table at other setting distances. Further, double feeds of aluminum foils can also be detected at distances shorter than the above. Please contact our office for details.
Standard sensing object size: 80 x 80 mm 3.150 x 3.150 in
Iron(SPCC): 0.07 to 0.5 mm 0.003 to 0.020 in
Aluminum: 0.03 to 2 mm 0.001 to 0.079 in
Copper: 0.03 to 2 mm 0.001 to 0.079 in
Brass: 0.03 to 2 mm 0.001 to 0.079 in
Stainless steel (SUS304): 0.1 to 2 mm 0.004 to 0.079 in
(Note) The above detectable sheet thicknesses are typical data at the given sensing distance. The allowable thickness will differ from the range described in the above table at other setting distances. Further, double feeds of aluminum foils can also be detected at distances shorter than the above. Please contact our office for details.
Standard sensing object size: 80 x 80 mm 3.150 x 3.150 in
Iron(SPCC): 0.01 to 0.1 mm 0.0004 to 0.004 in
Aluminum: 0.015 to 1 mm 0.001 to 0.039 in
Copper: 0.018 to 1 mm 0.001 to 0.039 in
Brass: 0.01 to 1 mm 0.0004 to 0.039 in
Stainless steel (SUS304): 0.05 to 1 mm 0.002 to 0.039 in
(Note) The above detectable sheet thicknesses are typical data at the given sensing distance. The allowable thickness will differ from the range described in the above table at other setting distances. Further, double feeds of aluminum foils can also be detected at distances shorter than the above. Please contact our office for details.
IP67 (IEC)-10 to +60 degrees +14 to +140 degrees Fahrenheit , Storage: -25 to +70 degrees -13 to +158 degrees Fahrenheit45 to 85 % RH, Storage: 35 to 95 % RH