Specification

Specifications table for model HG-TC111
ItemPerformance characteristics
CE Marking Directive ComplianceEMC Directive, RoHS Directive
Pollution Degree 2
Operating Altitude2,000 m 6561.68 ft or less
(Note) : Do not use or store in an environment that has been pressurized to an air pressure higher than the atmospheric pressure at 0 m.
Environmental Resistance: ProtectionIP40(IEC)
Environmental Resistance: Ambient Temperature-10 to +50 ℃ +14 to +122 ℉ (No dew condensation or icing allowed) (Note), Storage: -20 to +60 ℃ -4 to +140 ℉
(Note) : When slave units are connected to the master unit, the maximum sink current / source current of control output and ambient temperature vary depending on the number of connected slave units as shown below.
Number of connected slave units Maximum sink current and source
current of control output
Ambient temperature
  When communication unit
is connected
1 to 7 units 1 to 6 units 20 mA -10~+45℃
+14 to +113 ℉
8 to 15 units 7 to 14 units 10 mA
Environmental Resistance: Ambient Humidity35 to 85 % RH, Storage: 35 to 85 % RH
Environmental Resistance: Voltage Withstandability1,000 V AC for one minute between all supply terminals connected together and enclosure
Environmental Resistance: Insulation Resistance20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure
Environmental Resistance: Vibration Resistance10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude (10 to 58 Hz), Maximum acceleration 49 m/s2 (58 to 150 Hz) in X, Y and Z directions for two hours each
Environmental Resistance: Shock Resistance98m/s2 acceleration (10 G approx.) in X, Y and Z directions five times each
MaterialCase: Polycarbonate, Cover: Polycarbonate, Switches: Polyacetal
Cable0.15 mm2 7-core composite cable, 2 m 6.562 ft long
Net Weight 140 g approx.
Applicable Sensor HeadHG-T1010、HG-T1110
Number of Connectable UnitsUp to 15 slave units can be connected to a master unit.
(Note) : When connected to a communication unit for digital displacement sensor, up to 14 slave units can be connected per master unit.
Supply Voltage 24 V DC ±10 %, including ripple 0.5 V (P-P)
Current Consumption100 mA or less (when sensor head is connected)
(Note) : Current consumption does not include analog current output.
Analogue Output: Analog Voltage Output•Voltage output range: 1 to 5 V/F.S. (default value)
•Linearity: ±0.05 % F.S.
•Output when alarm occurs: 5.2 V
•Output impedance: 100 Ω max.
(Note) : Linearity is a value calculated from digitally measured values at F.S. = 16 mA for current output or F.S. = 4 V for voltage output.
Analogue Output: Analog Current Output•Current output range: 4 to 20 mA/F.S. (default value)
•Linearity: ±0.25 % F.S.
•Output when alarm occurs: 0 mA
•Load impedance: 250 Ω max.
(Note) : Linearity is a value calculated from digitally measured values at F.S. = 16 mA for current output or F.S. = 4 V for voltage output.
Control output(Output 1, Output 2, Output 3)NPN open-collector transistor
•Maximum sink current: 50 mA (Note)
•Applied voltage: 30 V DC or less (between output and 0 V)
•Residual voltage: 1.5 V or less (at 50 mA sink current)
•Leakage current: 0.1 mA or less


PNP open-collector transistor
•Maximum source current: 50 mA (Note)
•Applied voltage: 30 V DC or less (between output and +V)
•Residual voltage: 1.5 V or less (at 50 mA source current)
•Leakage current: 0.1 mA or less

(Note) : When slave units are connected to the master unit, the maximum sink current / source current of control output and ambient temperature vary depending on the number of connected slave units as shown below.
Number of connected slave units Maximum sink current and source
current of control output
Ambient temperature
  When communication unit
is connected
1 to 7 units 1 to 6 units 20 mA -10~+45℃
+14 to +113 ℉
8 to 15 units 7 to 14 units 10 mA
Control output(Output 1, Output 2, Output 3) : Short-circuit protectionIncorporated (automatic reset type)
Control output(Output 1, Output 2, Output 3) : Judgment outputN.O. / N.C. switching type
Control output(Output 1, Output 2, Output 3) : Alarm outputOpen when alarm occurs
External output switchingOutput 1, Output 2, and Output 3 can be switched to 3-value, 2-value, Logic, and Logic 2.
External input(Input 1, Input 2, Input 3)
Non-contact input or NPN open-collector transistor
•Input conditions
Invalid: +8 V to +V DC or open, Valid: 0 to +1.2 V DC
•Input impedance: 10 kΩ approx.


Non-contact input or PNP open-collector transistor
•Input conditions
Invalid: 0 to +0.6 V DC or open, Valid: +4 V to +V DC
•Input impedance: 10 kΩ approx.
External input(Input 1, Input 2, Input 3) : Input time• Trigger input: 2 ms or more (ON)
• Laser emission stop input, preset input, reset input, bank input A/B(Note): 20 ms or more (ON)
(Note) : Average count (response time) is for when the sampling cycle is set to 1 ms (standard sampling). Response times differ when the sampling cycle is set to 0.5 ms (high-speed sampling).
External input switchingInput 1, Input 2, and Input 3 can be switched to "Preset / Reset / Trigger", "Bank Input A / Bank Input B / Select (Preset, Reset, Trigger)", or "Laser emission stop".
Sampling Rate1 ms (standard sampling) / 0.5 ms (high-speed sampling)
Average count (response time)1 time (2 ms), 2 times (3 ms), 4 times (5 ms), 8 times (9 ms), 16 times (17 ms), 32 times (33 ms), 64 times (65 ms), 128 times (129 ms), 256 times (257 ms), 512 times (513 ms), and 1,024 times (1,025 ms) switching type
(Note) : Average count (response time) is for when the sampling cycle is set to 1 ms (standard sampling). Response times differ when the sampling cycle is set to 0.5 ms (high-speed sampling).
Display: Resolution1 μm 0.039 mil
Display: Display Range-199.999 to 199.999 mm -7.874 to 7.874 in