The SC Sensor - PLC Connection System allows up to 16 I/O devices from any Sensor. Amplifiers from Panasonic's Fiber, Laser and Pressure Sensors can be connected in a side-by-side configuration. In addition, using the Connector input/output extension unit, Photoelectric, Micro Photoelectric, Inductive Proximity and any other types of Sensors or Switches can be connected to an output device with just one touch.
Sensor-PLC Connection System SC
Part number list
Results 5
Models table for series Sensor-PLC Connection System SC
1 A or less (Same as maximum permissible current consumption of all units connected to SC-MIL-S.) (Note: When either the permissible current amount of power supply unit or the permissible current amount of cable to be connected is less than allowable through current value, adjust the current to the smallest value.
.)
Connectable up to 16 channels (The signal from up to 16th point (counting from unit adjacent to SC-MIL) of all units connected to SC-MIL is transferred. However, the signal thereafter is not transferred. Note that SC-MIL-S does not occupy any signal point.)
10 m 32.808 ft or less (the distance between SC-MIL and PLC and that between SC-MIL and SC-MIL-S put together)
–10 to +45 ℃ +14 to +113 ℉ (No dew condensation or icing allowed), Storage: –20 to +70 ℃ –4 to +158 ℉
12 to 24 V DC plus or minus 10 % (In combination with SC-TP8J, the unit can be also used with a power supply of 5 to 24 V DC plus or minus 10 %.) (Note:The plug-in sensor main unit SC-MIL incorporates a cable lead-out connector in addition to the MIL connector, which allows to receive the supply voltage from the separate power supply.)
2 A or less (Same as maximum permissible current consumption of all units connected toSC-MIL-S.) (Note:When either the permissible current amount of power supply unit or the permissible current amount of cable to be connected is less than allowable through current value, adjust the current to the smallest value.
.)
Connectable up to 16 channels (The signal from up to 16th point (counting from unit adjacent to SC-MIL-S) of all units connected to SC-MIL-S is transferred. However, the signal thereafter is not transferred. Note that SC-MIL-S does not occupy any signal point.)
10 m 32.808 ft or less (the distance between SC-MIL and PLC and that between SC-MIL and SC-MIL-S put together)
–10 to +45 ℃ +14 to +113 ℉ (No dew condensation or icing allowed), Storage: –20 to +70 ℃ –4 to +158 ℉
1 A or less (Same as maximum permissible current consumption of all units connected to SC-MIL-S.) (Note: When either the permissible current amount of power supply unit or the permissible current amount of cable to be connected is less than allowable through current value, adjust the current to the smallest value.
.)
Connectable up to 16 channels (The signal from up to 16th point (counting from unit adjacent to SC-MIL) of all units connected to SC-MIL is transferred. However, the signal thereafter is not transferred. Note that SC-MIL-S does not occupy any signal point.)
10 m 32.808 ft or less (the distance between SC-MIL and PLC and that between SC-MIL and SC-MIL-S put together)
–10 to +45 ℃ +14 to +113 ℉ (No dew condensation or icing allowed), Storage: –20 to +70 ℃ –4 to +158 ℉
12 to 24 V DC plus or minus 10 % (In combination with SC-TP8J, the unit can be also used with a power supply of 5 to 24 V DC plus or minus 10 %.) (Note:The plug-in sensor main unit SC-MIL incorporates a cable lead-out connector in addition to the MIL connector, which allows to receive the supply voltage from the separate power supply.)
2 A or less (Same as maximum permissible current consumption of all units connected toSC-MIL-S.) (Note:When either the permissible current amount of power supply unit or the permissible current amount of cable to be connected is less than allowable through current value, adjust the current to the smallest value.
.)
Connectable up to 16 channels (The signal from up to 16th point (counting from unit adjacent to SC-MIL-S) of all units connected to SC-MIL-S is transferred. However, the signal thereafter is not transferred. Note that SC-MIL-S does not occupy any signal point.)
10 m 32.808 ft or less (the distance between SC-MIL and PLC and that between SC-MIL and SC-MIL-S put together)
–10 to +45 ℃ +14 to +113 ℉ (No dew condensation or icing allowed), Storage: –20 to +70 ℃ –4 to +158 ℉