| | 3 mm 0.118 in plus or minus 10 % (Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. | 0 to 2.4 mm 0 to 0.094 in (Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation. | Iron sheet 12 × 12 × t 1 mm 0.472 × 0.472 × t 0.039 in | 20 % or less of operation distance (with standard sensing object) | 12 to 24 V DC +10 /-15 % Ripple P-P 10 % or less | 0.8 mA or less (Note) It is the leakage current when the output is in the OFF state. | Non-contact DC 2-wire type - Load current: 3 to 70 mA (Note 1) - Residual voltage: 3 V or less (Note 2) (Note 1) The maximum load current varies depending on the ambient temperature. (Note 2) When the cable is extended, the residual voltage becomes larger. | Incorporated | 1.2 kHz | | Lights up in green under stable sensing condition lights up in orange under unstable sensing condition | IP67 (IEC), IP67g (JEM) (Note:If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil.
Please check the resistivity of the sensor against the cutting oil you are using beforehand.) | -25 to +70 ℃ -13 to +158℉, Storage: -30 to +80 ℃ -22 to +176℉ | 45 to 85 % RH, Storage: 35 to 95 % RH | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 50 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure | 10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each | 1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions three times each | Over ambient temperature range -25 to +70 ℃ -13 to +158℉ : within plus or minus10 % of sensing range at +20 ℃ +68℉ | Within plus or minus2 % for plus or minus10 % fluctuation of the supply voltage | Enclosure: Brass (Nickel plated) Sensing part: Nylon Indicator part: Nylon | | | | Nut: 2 pcs., Toothed lock washer: 1 pc. |
| | 3 mm 0.118 in plus or minus 10 % (Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. | 0 to 2.4 mm 0 to 0.094 in (Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation. | Iron sheet 12 × 12 × t 1 mm 0.472 × 0.472 × t 0.039 in | 20 % or less of operation distance (with standard sensing object) | 12 to 24 V DC +10 /-15 % Ripple P-P 10 % or less | 0.8 mA or less (Note) It is the leakage current when the output is in the OFF state. | Non-contact DC 2-wire type - Load current: 3 to 70 mA (Note 1) - Residual voltage: 3 V or less (Note 2) (Note 1) The maximum load current varies depending on the ambient temperature. (Note 2) When the cable is extended, the residual voltage becomes larger. | Incorporated | 1.2 kHz | Orange LED (lights up when the output is ON) | | IP67 (IEC), IP67g (JEM) (Note:If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil.
Please check the resistivity of the sensor against the cutting oil you are using beforehand.) | -25 to +70 ℃ -13 to +158℉, Storage: -30 to +80 ℃ -22 to +176℉ | 45 to 85 % RH, Storage: 35 to 95 % RH | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 50 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure | 10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each | 1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions three times each | Over ambient temperature range -25 to +70 ℃ -13 to +158℉ : within plus or minus10 % of sensing range at +20 ℃ +68℉ | Within plus or minus2 % for plus or minus10 % fluctuation of the supply voltage | Enclosure: Brass (Nickel plated) Sensing part: Nylon Indicator part: Nylon | 0.3 mm2 2-core oil, heat and cold resistant cabtyre cable, 2 m 6.562 ft long | Extension up to total 50 m 164.042 ft is possible with 0.3 mm2, or more, cable. | Net weight:
55 g approx. | Nut: 2 pcs., Toothed lock washer: 1 pc. |
| | 8 mm 0.315 in plus or minus 10 % (Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. | 0 to 6.4 mm 0 to 0.252 in (Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation. | Iron sheet 30 × 30 × t 1 mm 1.181 × 1.181 × t 0.039 in | 20 % or less of operation distance (with standard sensing object) | 12 to 24 V DC +10 /-15 % Ripple P-P 10 % or less | 0.8 mA or less (Note) It is the leakage current when the output is in the OFF state. | Non-contact DC 2-wire type - Load current: 3 to 70 mA (Note 1) - Residual voltage: 3 V or less (Note 2) (Note 1) The maximum load current varies depending on the ambient temperature. (Note 2) When the cable is extended, the residual voltage becomes larger. | Incorporated | 650 Hz | Normally closed type: Orange LED (lights up when the output is ON) | Lights up in green under stable sensing condition lights up in orange under unstable sensing condition | IP67 (IEC), IP67g (JEM) (Note:If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil.
Please check the resistivity of the sensor against the cutting oil you are using beforehand.) | -25 to +70 ℃ -13 to +158℉, Storage: -30 to +80 ℃ -22 to +176℉ | 45 to 85 % RH, Storage: 35 to 95 % RH | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 50 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure | 10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each | 1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions three times each | Over ambient temperature range -25 to +70 ℃ -13 to +158℉ : within plus or minus10 % of sensing range at +20 ℃ +68℉ | Within plus or minus2 % for plus or minus10 % fluctuation of the supply voltage | Enclosure: Brass (Nickel plated) Sensing part: Nylon Indicator part: Nylon | | | | Nut: 2 pcs., Toothed lock washer: 1 pc. |
| | 8 mm 0.315 in plus or minus 10 % (Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. | 0 to 6.4 mm 0 to 0.252 in (Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation. | Iron sheet 30 × 30 × t 1 mm 1.181 × 1.181 × t 0.039 in | 20 % or less of operation distance (with standard sensing object) | 12 to 24 V DC +10 /-15 % Ripple P-P 10 % or less | 0.8 mA or less (Note) It is the leakage current when the output is in the OFF state. | Non-contact DC 2-wire type - Load current: 3 to 70 mA (Note 1) - Residual voltage: 3 V or less (Note 2) (Note 1) The maximum load current varies depending on the ambient temperature. (Note 2) When the cable is extended, the residual voltage becomes larger. | Incorporated | 650 Hz | Orange LED (lights up when the output is ON) | | IP67 (IEC), IP67g (JEM) (Note:If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil.
Please check the resistivity of the sensor against the cutting oil you are using beforehand.) | -25 to +70 ℃ -13 to +158℉, Storage: -30 to +80 ℃ -22 to +176℉ | 45 to 85 % RH, Storage: 35 to 95 % RH | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 50 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure | 10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each | 1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions three times each | Over ambient temperature range -25 to +70 ℃ -13 to +158℉ : within plus or minus10 % of sensing range at +20 ℃ +68℉ | Within plus or minus2 % for plus or minus10 % fluctuation of the supply voltage | Enclosure: Brass (Nickel plated) Sensing part: Nylon Indicator part: Nylon | | | | Nut: 2 pcs., Toothed lock washer: 1 pc. |
| | 8 mm 0.315 in plus or minus 10 % (Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. | 0 to 6.4 mm 0 to 0.252 in (Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation. | Iron sheet 30 × 30 × t 1 mm 1.181 × 1.181 × t 0.039 in | 20 % or less of operation distance (with standard sensing object) | 12 to 24 V DC +10 /-15 % Ripple P-P 10 % or less | 0.8 mA or less (Note) It is the leakage current when the output is in the OFF state. | Non-contact DC 2-wire type - Load current: 3 to 70 mA (Note 1) - Residual voltage: 3 V or less (Note 2) (Note 1) The maximum load current varies depending on the ambient temperature. (Note 2) When the cable is extended, the residual voltage becomes larger. | Incorporated | 650 Hz | Normally closed type: Orange LED (lights up when the output is ON) | Lights up in green under stable sensing condition lights up in orange under unstable sensing condition | IP67 (IEC), IP67g (JEM) (Note:If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil.
Please check the resistivity of the sensor against the cutting oil you are using beforehand.) | -25 to +70 ℃ -13 to +158℉, Storage: -30 to +80 ℃ -22 to +176℉ | 45 to 85 % RH, Storage: 35 to 95 % RH | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 50 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure | 10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each | 1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions three times each | Over ambient temperature range -25 to +70 ℃ -13 to +158℉ : within plus or minus10 % of sensing range at +20 ℃ +68℉ | Within plus or minus2 % for plus or minus10 % fluctuation of the supply voltage | Enclosure: Brass (Nickel plated) Sensing part: Nylon Indicator part: Nylon | | | | Nut: 2 pcs., Toothed lock washer: 1 pc. |
| | 22 mm 0.866 in plus or minus 10 % (Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. | 0 to 17.6 mm 0 to 0.693 in (Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation. | Iron sheet 70 × 70 × t 1 mm 2.756 × 2.756 × t 0.039 in | 20 % or less of operation distance (with standard sensing object) | 12 to 24 V DC +10 /-15 % Ripple P-P 10 % or less | 0.8 mA or less (Note) It is the leakage current when the output is in the OFF state. | Non-contact DC 2-wire type - Load current: 3 to 70 mA (Note 1) - Residual voltage: 3 V or less (Note 2) (Note 1) The maximum load current varies depending on the ambient temperature. (Note 2) When the cable is extended, the residual voltage becomes larger. | Incorporated | 220 Hz | Normally closed type: Orange LED (lights up when the output is ON) | Lights up in green under stable sensing condition lights up in orange under unstable sensing condition | IP67 (IEC), IP67g (JEM) (Note:If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil.
Please check the resistivity of the sensor against the cutting oil you are using beforehand.) | -25 to +70 ℃ -13 to +158℉, Storage: -30 to +80 ℃ -22 to +176℉ | 45 to 85 % RH, Storage: 35 to 95 % RH | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 50 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure | 10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each | 1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions three times each | Over ambient temperature range -25 to +70 ℃ -13 to +158℉ : within plus or minus10 % of sensing range at +20 ℃ +68℉ | Within plus or minus2 % for plus or minus10 % fluctuation of the supply voltage | Enclosure: Brass (Nickel plated) Sensing part: Nylon Indicator part: Nylon | 0.3 mm2 2-core oil, heat and cold resistant cabtyre cable, 2 m 6.562 ft long | Extension up to total 50 m 164.042 ft is possible with 0.3 mm2, or more, cable. | Net weight:
220 g approx. | Nut: 2 pcs., Toothed lock washer: 1 pc. |
| | 7 mm 0.276 in plus or minus 10 % (Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. | 0 to 5.6 mm 0 to 0.220 in (Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation. | Iron sheet 18 × 18 × t 1 mm 0.709 × 0.709 × t 0.039 in | 20 % or less of operation distance (with standard sensing object) | 12 to 24 V DC +10 /-15 % Ripple P-P 10 % or less | 0.8 mA or less (Note) It is the leakage current when the output is in the OFF state. | Non-contact DC 2-wire type - Load current: 3 to 70 mA (Note 1) - Residual voltage: 3 V or less (Note 2) (Note 1) The maximum load current varies depending on the ambient temperature. (Note 2) When the cable is extended, the residual voltage becomes larger. | Incorporated | 500 Hz | Orange LED (lights up when the output is ON) | | IP67 (IEC), IP67g (JEM) (Note:If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil.
Please check the resistivity of the sensor against the cutting oil you are using beforehand.) | -25 to +70 ℃ -13 to +158℉, Storage: -30 to +80 ℃ -22 to +176℉ | 45 to 85 % RH, Storage: 35 to 95 % RH | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 50 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure | 10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each | 1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions three times each | Over ambient temperature range -25 to +70 ℃ -13 to +158℉ : within plus or minus10 % of sensing range at +20 ℃ +68℉ | Within plus or minus2 % for plus or minus10 % fluctuation of the supply voltage | Enclosure: Brass (Nickel plated) Sensing part: Nylon Indicator part: Nylon | | | | Nut: 2 pcs., Toothed lock washer: 1 pc. |
| | 15 mm 0.591 in plus or minus 10 % (Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. | 0 to 12 mm 0 to 0.472 in (Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation. | Iron sheet 50 × 50 × t 1 mm 1.969 × 1.969 × t 0.039 in | 20 % or less of operation distance (with standard sensing object) | 12 to 24 V DC +10 /-15 % Ripple P-P 10 % or less | 0.8 mA or less (Note) It is the leakage current when the output is in the OFF state. | Non-contact DC 2-wire type - Load current: 3 to 70 mA (Note 1) - Residual voltage: 3 V or less (Note 2) (Note 1) The maximum load current varies depending on the ambient temperature. (Note 2) When the cable is extended, the residual voltage becomes larger. | Incorporated | 350 Hz | Normally closed type: Orange LED (lights up when the output is ON) | Lights up in green under stable sensing condition lights up in orange under unstable sensing condition | IP67 (IEC), IP67g (JEM) (Note:If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil.
Please check the resistivity of the sensor against the cutting oil you are using beforehand.) | -25 to +70 ℃ -13 to +158℉, Storage: -30 to +80 ℃ -22 to +176℉ | 45 to 85 % RH, Storage: 35 to 95 % RH | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 50 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure | 10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each | 1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions three times each | Over ambient temperature range -25 to +70 ℃ -13 to +158℉ : within plus or minus10 % of sensing range at +20 ℃ +68℉ | Within plus or minus2 % for plus or minus10 % fluctuation of the supply voltage | Enclosure: Brass (Nickel plated) Sensing part: Nylon Indicator part: Nylon | 0.3 mm2 2-core oil, heat and cold resistant cabtyre cable, 2 m 6.562 ft long | Extension up to total 50 m 164.042 ft is possible with 0.3 mm2, or more, cable. | Net weight:
95 g approx. | Nut: 2 pcs., Toothed lock washer: 1 pc. |
| | 15 mm 0.591 in plus or minus 10 % (Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. | 0 to 12 mm 0 to 0.472 in (Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation. | Iron sheet 50 × 50 × t 1 mm 1.969 × 1.969 × t 0.039 in | 20 % or less of operation distance (with standard sensing object) | 12 to 24 V DC +10 /-15 % Ripple P-P 10 % or less | 0.8 mA or less (Note) It is the leakage current when the output is in the OFF state. | Non-contact DC 2-wire type - Load current: 3 to 70 mA (Note 1) - Residual voltage: 3 V or less (Note 2) (Note 1) The maximum load current varies depending on the ambient temperature. (Note 2) When the cable is extended, the residual voltage becomes larger. | Incorporated | 350 Hz | Normally closed type: Orange LED (lights up when the output is ON) | Lights up in green under stable sensing condition lights up in orange under unstable sensing condition | IP67 (IEC), IP67g (JEM) (Note:If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil.
Please check the resistivity of the sensor against the cutting oil you are using beforehand.) | -25 to +70 ℃ -13 to +158℉, Storage: -30 to +80 ℃ -22 to +176℉ | 45 to 85 % RH, Storage: 35 to 95 % RH | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 50 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure | 10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each | 1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions three times each | Over ambient temperature range -25 to +70 ℃ -13 to +158℉ : within plus or minus10 % of sensing range at +20 ℃ +68℉ | Within plus or minus2 % for plus or minus10 % fluctuation of the supply voltage | Enclosure: Brass (Nickel plated) Sensing part: Nylon Indicator part: Nylon | | | | Nut: 2 pcs., Toothed lock washer: 1 pc. |
| | 15 mm 0.591 in plus or minus 10 % (Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. | 0 to 12 mm 0 to 0.472 in (Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation. | Iron sheet 50 × 50 × t 1 mm 1.969 × 1.969 × t 0.039 in | 20 % or less of operation distance (with standard sensing object) | 12 to 24 V DC +10 /-15 % Ripple P-P 10 % or less | 0.8 mA or less (Note) It is the leakage current when the output is in the OFF state. | Non-contact DC 2-wire type - Load current: 3 to 70 mA (Note 1) - Residual voltage: 3 V or less (Note 2) (Note 1) The maximum load current varies depending on the ambient temperature. (Note 2) When the cable is extended, the residual voltage becomes larger. | Incorporated | 350 Hz | Orange LED (lights up when the output is ON) | | IP67 (IEC), IP67g (JEM) (Note:If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil.
Please check the resistivity of the sensor against the cutting oil you are using beforehand.) | -25 to +70 ℃ -13 to +158℉, Storage: -30 to +80 ℃ -22 to +176℉ | 45 to 85 % RH, Storage: 35 to 95 % RH | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 50 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure | 10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each | 1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions three times each | Over ambient temperature range -25 to +70 ℃ -13 to +158℉ : within plus or minus10 % of sensing range at +20 ℃ +68℉ | Within plus or minus2 % for plus or minus10 % fluctuation of the supply voltage | Enclosure: Brass (Nickel plated) Sensing part: Nylon Indicator part: Nylon | 0.3 mm2 2-core oil, heat and cold resistant cabtyre cable, 2 m 6.562 ft long | Extension up to total 50 m 164.042 ft is possible with 0.3 mm2, or more, cable. | Net weight:
95 g approx. | Nut: 2 pcs., Toothed lock washer: 1 pc. |