These compact Cylindrical Inductive Proximity Sensors with built-in amplifier offer an improved sensing range that is 1.6 times longer than Panasonic's previous model [GX-12ML(B)] and can be mounted at a greater distance from the object. Having their enclosure and pigtail cable entirely coated with a fluorine resin makes them splatter-resistant so they can be safely used in applications prone to splatter.
3 mm 0.118 in plus or minus 10 % (Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 2.4 mm 0 to 0.094 in (Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 12 × 12 × t 1 mm 0.472 × 0.472 × t 0.039 in
20 % or less of operation distance (with standard sensing object)
12 to 24 V DC +10 /-15 % Ripple P-P 10 % or less
0.8 mA or less (Note) It is the leakage current when the output is in the OFF state.
Non-contact DC 2-wire type - Load current: 3 to 70 mA (Note 1) - Residual voltage: 3 V or less (Note 2) (Note 1) The maximum load current varies depending on the ambient temperature. (Note 2) When the cable is extended, the residual voltage becomes larger.
Incorporated
1.2 kHz
Lights up in green under stable sensing condition lights up in orange under unstable sensing condition
IP67 (IEC), IP67g (JEM) (Note:If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil.
Please check the resistivity of the sensor against the cutting oil you are using beforehand.)
-25 to +70 ℃ -13 to +158℉, Storage: -30 to +80 ℃ -22 to +176℉
45 to 85 % RH, Storage: 35 to 95 % RH
1,000 V AC for one min. between all supply terminals connected together and enclosure
50 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions three times each
Over ambient temperature range -25 to +70 ℃ -13 to +158℉ : within plus or minus10 % of sensing range at +20 ℃ +68℉
Within plus or minus2 % for plus or minus10 % fluctuation of the supply voltage
3 mm 0.118 in plus or minus 10 % (Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 2.4 mm 0 to 0.094 in (Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 12 × 12 × t 1 mm 0.472 × 0.472 × t 0.039 in
20 % or less of operation distance (with standard sensing object)
12 to 24 V DC +10 /-15 % Ripple P-P 10 % or less
0.8 mA or less (Note) It is the leakage current when the output is in the OFF state.
Non-contact DC 2-wire type - Load current: 3 to 70 mA (Note 1) - Residual voltage: 3 V or less (Note 2) (Note 1) The maximum load current varies depending on the ambient temperature. (Note 2) When the cable is extended, the residual voltage becomes larger.
Incorporated
1.2 kHz
Orange LED (lights up when the output is ON)
IP67 (IEC), IP67g (JEM) (Note:If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil.
Please check the resistivity of the sensor against the cutting oil you are using beforehand.)
-25 to +70 ℃ -13 to +158℉, Storage: -30 to +80 ℃ -22 to +176℉
45 to 85 % RH, Storage: 35 to 95 % RH
1,000 V AC for one min. between all supply terminals connected together and enclosure
50 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions three times each
Over ambient temperature range -25 to +70 ℃ -13 to +158℉ : within plus or minus10 % of sensing range at +20 ℃ +68℉
Within plus or minus2 % for plus or minus10 % fluctuation of the supply voltage
8 mm 0.315 in plus or minus 10 % (Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 6.4 mm 0 to 0.252 in (Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 30 × 30 × t 1 mm 1.181 × 1.181 × t 0.039 in
20 % or less of operation distance (with standard sensing object)
12 to 24 V DC +10 /-15 % Ripple P-P 10 % or less
0.8 mA or less (Note) It is the leakage current when the output is in the OFF state.
Non-contact DC 2-wire type - Load current: 3 to 70 mA (Note 1) - Residual voltage: 3 V or less (Note 2) (Note 1) The maximum load current varies depending on the ambient temperature. (Note 2) When the cable is extended, the residual voltage becomes larger.
Incorporated
650 Hz
Normally closed type: Orange LED (lights up when the output is ON)
Lights up in green under stable sensing condition lights up in orange under unstable sensing condition
IP67 (IEC), IP67g (JEM) (Note:If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil.
Please check the resistivity of the sensor against the cutting oil you are using beforehand.)
-25 to +70 ℃ -13 to +158℉, Storage: -30 to +80 ℃ -22 to +176℉
45 to 85 % RH, Storage: 35 to 95 % RH
1,000 V AC for one min. between all supply terminals connected together and enclosure
50 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions three times each
Over ambient temperature range -25 to +70 ℃ -13 to +158℉ : within plus or minus10 % of sensing range at +20 ℃ +68℉
Within plus or minus2 % for plus or minus10 % fluctuation of the supply voltage
8 mm 0.315 in plus or minus 10 % (Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 6.4 mm 0 to 0.252 in (Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 30 × 30 × t 1 mm 1.181 × 1.181 × t 0.039 in
20 % or less of operation distance (with standard sensing object)
12 to 24 V DC +10 /-15 % Ripple P-P 10 % or less
0.8 mA or less (Note) It is the leakage current when the output is in the OFF state.
Non-contact DC 2-wire type - Load current: 3 to 70 mA (Note 1) - Residual voltage: 3 V or less (Note 2) (Note 1) The maximum load current varies depending on the ambient temperature. (Note 2) When the cable is extended, the residual voltage becomes larger.
Incorporated
650 Hz
Orange LED (lights up when the output is ON)
IP67 (IEC), IP67g (JEM) (Note:If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil.
Please check the resistivity of the sensor against the cutting oil you are using beforehand.)
-25 to +70 ℃ -13 to +158℉, Storage: -30 to +80 ℃ -22 to +176℉
45 to 85 % RH, Storage: 35 to 95 % RH
1,000 V AC for one min. between all supply terminals connected together and enclosure
50 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions three times each
Over ambient temperature range -25 to +70 ℃ -13 to +158℉ : within plus or minus10 % of sensing range at +20 ℃ +68℉
Within plus or minus2 % for plus or minus10 % fluctuation of the supply voltage
8 mm 0.315 in plus or minus 10 % (Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 6.4 mm 0 to 0.252 in (Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 30 × 30 × t 1 mm 1.181 × 1.181 × t 0.039 in
20 % or less of operation distance (with standard sensing object)
12 to 24 V DC +10 /-15 % Ripple P-P 10 % or less
0.8 mA or less (Note) It is the leakage current when the output is in the OFF state.
Non-contact DC 2-wire type - Load current: 3 to 70 mA (Note 1) - Residual voltage: 3 V or less (Note 2) (Note 1) The maximum load current varies depending on the ambient temperature. (Note 2) When the cable is extended, the residual voltage becomes larger.
Incorporated
650 Hz
Normally closed type: Orange LED (lights up when the output is ON)
Lights up in green under stable sensing condition lights up in orange under unstable sensing condition
IP67 (IEC), IP67g (JEM) (Note:If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil.
Please check the resistivity of the sensor against the cutting oil you are using beforehand.)
-25 to +70 ℃ -13 to +158℉, Storage: -30 to +80 ℃ -22 to +176℉
45 to 85 % RH, Storage: 35 to 95 % RH
1,000 V AC for one min. between all supply terminals connected together and enclosure
50 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions three times each
Over ambient temperature range -25 to +70 ℃ -13 to +158℉ : within plus or minus10 % of sensing range at +20 ℃ +68℉
Within plus or minus2 % for plus or minus10 % fluctuation of the supply voltage
22 mm 0.866 in plus or minus 10 % (Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 17.6 mm 0 to 0.693 in (Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 70 × 70 × t 1 mm 2.756 × 2.756 × t 0.039 in
20 % or less of operation distance (with standard sensing object)
12 to 24 V DC +10 /-15 % Ripple P-P 10 % or less
0.8 mA or less (Note) It is the leakage current when the output is in the OFF state.
Non-contact DC 2-wire type - Load current: 3 to 70 mA (Note 1) - Residual voltage: 3 V or less (Note 2) (Note 1) The maximum load current varies depending on the ambient temperature. (Note 2) When the cable is extended, the residual voltage becomes larger.
Incorporated
220 Hz
Normally closed type: Orange LED (lights up when the output is ON)
Lights up in green under stable sensing condition lights up in orange under unstable sensing condition
IP67 (IEC), IP67g (JEM) (Note:If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil.
Please check the resistivity of the sensor against the cutting oil you are using beforehand.)
-25 to +70 ℃ -13 to +158℉, Storage: -30 to +80 ℃ -22 to +176℉
45 to 85 % RH, Storage: 35 to 95 % RH
1,000 V AC for one min. between all supply terminals connected together and enclosure
50 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions three times each
Over ambient temperature range -25 to +70 ℃ -13 to +158℉ : within plus or minus10 % of sensing range at +20 ℃ +68℉
Within plus or minus2 % for plus or minus10 % fluctuation of the supply voltage
7 mm 0.276 in plus or minus 10 % (Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 5.6 mm 0 to 0.220 in (Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 18 × 18 × t 1 mm 0.709 × 0.709 × t 0.039 in
20 % or less of operation distance (with standard sensing object)
12 to 24 V DC +10 /-15 % Ripple P-P 10 % or less
0.8 mA or less (Note) It is the leakage current when the output is in the OFF state.
Non-contact DC 2-wire type - Load current: 3 to 70 mA (Note 1) - Residual voltage: 3 V or less (Note 2) (Note 1) The maximum load current varies depending on the ambient temperature. (Note 2) When the cable is extended, the residual voltage becomes larger.
Incorporated
500 Hz
Orange LED (lights up when the output is ON)
IP67 (IEC), IP67g (JEM) (Note:If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil.
Please check the resistivity of the sensor against the cutting oil you are using beforehand.)
-25 to +70 ℃ -13 to +158℉, Storage: -30 to +80 ℃ -22 to +176℉
45 to 85 % RH, Storage: 35 to 95 % RH
1,000 V AC for one min. between all supply terminals connected together and enclosure
50 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions three times each
Over ambient temperature range -25 to +70 ℃ -13 to +158℉ : within plus or minus10 % of sensing range at +20 ℃ +68℉
Within plus or minus2 % for plus or minus10 % fluctuation of the supply voltage
15 mm 0.591 in plus or minus 10 % (Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 12 mm 0 to 0.472 in (Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 50 × 50 × t 1 mm 1.969 × 1.969 × t 0.039 in
20 % or less of operation distance (with standard sensing object)
12 to 24 V DC +10 /-15 % Ripple P-P 10 % or less
0.8 mA or less (Note) It is the leakage current when the output is in the OFF state.
Non-contact DC 2-wire type - Load current: 3 to 70 mA (Note 1) - Residual voltage: 3 V or less (Note 2) (Note 1) The maximum load current varies depending on the ambient temperature. (Note 2) When the cable is extended, the residual voltage becomes larger.
Incorporated
350 Hz
Normally closed type: Orange LED (lights up when the output is ON)
Lights up in green under stable sensing condition lights up in orange under unstable sensing condition
IP67 (IEC), IP67g (JEM) (Note:If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil.
Please check the resistivity of the sensor against the cutting oil you are using beforehand.)
-25 to +70 ℃ -13 to +158℉, Storage: -30 to +80 ℃ -22 to +176℉
45 to 85 % RH, Storage: 35 to 95 % RH
1,000 V AC for one min. between all supply terminals connected together and enclosure
50 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions three times each
Over ambient temperature range -25 to +70 ℃ -13 to +158℉ : within plus or minus10 % of sensing range at +20 ℃ +68℉
Within plus or minus2 % for plus or minus10 % fluctuation of the supply voltage
15 mm 0.591 in plus or minus 10 % (Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 12 mm 0 to 0.472 in (Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 50 × 50 × t 1 mm 1.969 × 1.969 × t 0.039 in
20 % or less of operation distance (with standard sensing object)
12 to 24 V DC +10 /-15 % Ripple P-P 10 % or less
0.8 mA or less (Note) It is the leakage current when the output is in the OFF state.
Non-contact DC 2-wire type - Load current: 3 to 70 mA (Note 1) - Residual voltage: 3 V or less (Note 2) (Note 1) The maximum load current varies depending on the ambient temperature. (Note 2) When the cable is extended, the residual voltage becomes larger.
Incorporated
350 Hz
Normally closed type: Orange LED (lights up when the output is ON)
Lights up in green under stable sensing condition lights up in orange under unstable sensing condition
IP67 (IEC), IP67g (JEM) (Note:If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil.
Please check the resistivity of the sensor against the cutting oil you are using beforehand.)
-25 to +70 ℃ -13 to +158℉, Storage: -30 to +80 ℃ -22 to +176℉
45 to 85 % RH, Storage: 35 to 95 % RH
1,000 V AC for one min. between all supply terminals connected together and enclosure
50 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions three times each
Over ambient temperature range -25 to +70 ℃ -13 to +158℉ : within plus or minus10 % of sensing range at +20 ℃ +68℉
Within plus or minus2 % for plus or minus10 % fluctuation of the supply voltage
15 mm 0.591 in plus or minus 10 % (Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 12 mm 0 to 0.472 in (Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 50 × 50 × t 1 mm 1.969 × 1.969 × t 0.039 in
20 % or less of operation distance (with standard sensing object)
12 to 24 V DC +10 /-15 % Ripple P-P 10 % or less
0.8 mA or less (Note) It is the leakage current when the output is in the OFF state.
Non-contact DC 2-wire type - Load current: 3 to 70 mA (Note 1) - Residual voltage: 3 V or less (Note 2) (Note 1) The maximum load current varies depending on the ambient temperature. (Note 2) When the cable is extended, the residual voltage becomes larger.
Incorporated
350 Hz
Orange LED (lights up when the output is ON)
IP67 (IEC), IP67g (JEM) (Note:If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil.
Please check the resistivity of the sensor against the cutting oil you are using beforehand.)
-25 to +70 ℃ -13 to +158℉, Storage: -30 to +80 ℃ -22 to +176℉
45 to 85 % RH, Storage: 35 to 95 % RH
1,000 V AC for one min. between all supply terminals connected together and enclosure
50 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions three times each
Over ambient temperature range -25 to +70 ℃ -13 to +158℉ : within plus or minus10 % of sensing range at +20 ℃ +68℉
Within plus or minus2 % for plus or minus10 % fluctuation of the supply voltage
3 mm 0.118 in plus or minus 10 % (Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 2.4 mm 0 to 0.094 in (Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 12 × 12 × t 1 mm 0.472 × 0.472 × t 0.039 in
20 % or less of operation distance (with standard sensing object)
12 to 24 V DC +10 /-15 % Ripple P-P 10 % or less
0.8 mA or less (Note) It is the leakage current when the output is in the OFF state.
Non-contact DC 2-wire type - Load current: 3 to 70 mA (Note 1) - Residual voltage: 3 V or less (Note 2) (Note 1) The maximum load current varies depending on the ambient temperature. (Note 2) When the cable is extended, the residual voltage becomes larger.
Incorporated
1.2 kHz
Lights up in green under stable sensing condition lights up in orange under unstable sensing condition
IP67 (IEC), IP67g (JEM) (Note:If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil.
Please check the resistivity of the sensor against the cutting oil you are using beforehand.)
-25 to +70 ℃ -13 to +158℉, Storage: -30 to +80 ℃ -22 to +176℉
45 to 85 % RH, Storage: 35 to 95 % RH
1,000 V AC for one min. between all supply terminals connected together and enclosure
50 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions three times each
Over ambient temperature range -25 to +70 ℃ -13 to +158℉ : within plus or minus10 % of sensing range at +20 ℃ +68℉
Within plus or minus2 % for plus or minus10 % fluctuation of the supply voltage
3 mm 0.118 in plus or minus 10 % (Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 2.4 mm 0 to 0.094 in (Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 12 × 12 × t 1 mm 0.472 × 0.472 × t 0.039 in
20 % or less of operation distance (with standard sensing object)
12 to 24 V DC +10 /-15 % Ripple P-P 10 % or less
0.8 mA or less (Note) It is the leakage current when the output is in the OFF state.
Non-contact DC 2-wire type - Load current: 3 to 70 mA (Note 1) - Residual voltage: 3 V or less (Note 2) (Note 1) The maximum load current varies depending on the ambient temperature. (Note 2) When the cable is extended, the residual voltage becomes larger.
Incorporated
1.2 kHz
Orange LED (lights up when the output is ON)
IP67 (IEC), IP67g (JEM) (Note:If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil.
Please check the resistivity of the sensor against the cutting oil you are using beforehand.)
-25 to +70 ℃ -13 to +158℉, Storage: -30 to +80 ℃ -22 to +176℉
45 to 85 % RH, Storage: 35 to 95 % RH
1,000 V AC for one min. between all supply terminals connected together and enclosure
50 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions three times each
Over ambient temperature range -25 to +70 ℃ -13 to +158℉ : within plus or minus10 % of sensing range at +20 ℃ +68℉
Within plus or minus2 % for plus or minus10 % fluctuation of the supply voltage
8 mm 0.315 in plus or minus 10 % (Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 6.4 mm 0 to 0.252 in (Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 30 × 30 × t 1 mm 1.181 × 1.181 × t 0.039 in
20 % or less of operation distance (with standard sensing object)
12 to 24 V DC +10 /-15 % Ripple P-P 10 % or less
0.8 mA or less (Note) It is the leakage current when the output is in the OFF state.
Non-contact DC 2-wire type - Load current: 3 to 70 mA (Note 1) - Residual voltage: 3 V or less (Note 2) (Note 1) The maximum load current varies depending on the ambient temperature. (Note 2) When the cable is extended, the residual voltage becomes larger.
Incorporated
650 Hz
Normally closed type: Orange LED (lights up when the output is ON)
Lights up in green under stable sensing condition lights up in orange under unstable sensing condition
IP67 (IEC), IP67g (JEM) (Note:If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil.
Please check the resistivity of the sensor against the cutting oil you are using beforehand.)
-25 to +70 ℃ -13 to +158℉, Storage: -30 to +80 ℃ -22 to +176℉
45 to 85 % RH, Storage: 35 to 95 % RH
1,000 V AC for one min. between all supply terminals connected together and enclosure
50 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions three times each
Over ambient temperature range -25 to +70 ℃ -13 to +158℉ : within plus or minus10 % of sensing range at +20 ℃ +68℉
Within plus or minus2 % for plus or minus10 % fluctuation of the supply voltage
8 mm 0.315 in plus or minus 10 % (Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 6.4 mm 0 to 0.252 in (Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 30 × 30 × t 1 mm 1.181 × 1.181 × t 0.039 in
20 % or less of operation distance (with standard sensing object)
12 to 24 V DC +10 /-15 % Ripple P-P 10 % or less
0.8 mA or less (Note) It is the leakage current when the output is in the OFF state.
Non-contact DC 2-wire type - Load current: 3 to 70 mA (Note 1) - Residual voltage: 3 V or less (Note 2) (Note 1) The maximum load current varies depending on the ambient temperature. (Note 2) When the cable is extended, the residual voltage becomes larger.
Incorporated
650 Hz
Orange LED (lights up when the output is ON)
IP67 (IEC), IP67g (JEM) (Note:If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil.
Please check the resistivity of the sensor against the cutting oil you are using beforehand.)
-25 to +70 ℃ -13 to +158℉, Storage: -30 to +80 ℃ -22 to +176℉
45 to 85 % RH, Storage: 35 to 95 % RH
1,000 V AC for one min. between all supply terminals connected together and enclosure
50 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions three times each
Over ambient temperature range -25 to +70 ℃ -13 to +158℉ : within plus or minus10 % of sensing range at +20 ℃ +68℉
Within plus or minus2 % for plus or minus10 % fluctuation of the supply voltage
8 mm 0.315 in plus or minus 10 % (Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 6.4 mm 0 to 0.252 in (Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 30 × 30 × t 1 mm 1.181 × 1.181 × t 0.039 in
20 % or less of operation distance (with standard sensing object)
12 to 24 V DC +10 /-15 % Ripple P-P 10 % or less
0.8 mA or less (Note) It is the leakage current when the output is in the OFF state.
Non-contact DC 2-wire type - Load current: 3 to 70 mA (Note 1) - Residual voltage: 3 V or less (Note 2) (Note 1) The maximum load current varies depending on the ambient temperature. (Note 2) When the cable is extended, the residual voltage becomes larger.
Incorporated
650 Hz
Normally closed type: Orange LED (lights up when the output is ON)
Lights up in green under stable sensing condition lights up in orange under unstable sensing condition
IP67 (IEC), IP67g (JEM) (Note:If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil.
Please check the resistivity of the sensor against the cutting oil you are using beforehand.)
-25 to +70 ℃ -13 to +158℉, Storage: -30 to +80 ℃ -22 to +176℉
45 to 85 % RH, Storage: 35 to 95 % RH
1,000 V AC for one min. between all supply terminals connected together and enclosure
50 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions three times each
Over ambient temperature range -25 to +70 ℃ -13 to +158℉ : within plus or minus10 % of sensing range at +20 ℃ +68℉
Within plus or minus2 % for plus or minus10 % fluctuation of the supply voltage
22 mm 0.866 in plus or minus 10 % (Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 17.6 mm 0 to 0.693 in (Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 70 × 70 × t 1 mm 2.756 × 2.756 × t 0.039 in
20 % or less of operation distance (with standard sensing object)
12 to 24 V DC +10 /-15 % Ripple P-P 10 % or less
0.8 mA or less (Note) It is the leakage current when the output is in the OFF state.
Non-contact DC 2-wire type - Load current: 3 to 70 mA (Note 1) - Residual voltage: 3 V or less (Note 2) (Note 1) The maximum load current varies depending on the ambient temperature. (Note 2) When the cable is extended, the residual voltage becomes larger.
Incorporated
220 Hz
Normally closed type: Orange LED (lights up when the output is ON)
Lights up in green under stable sensing condition lights up in orange under unstable sensing condition
IP67 (IEC), IP67g (JEM) (Note:If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil.
Please check the resistivity of the sensor against the cutting oil you are using beforehand.)
-25 to +70 ℃ -13 to +158℉, Storage: -30 to +80 ℃ -22 to +176℉
45 to 85 % RH, Storage: 35 to 95 % RH
1,000 V AC for one min. between all supply terminals connected together and enclosure
50 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions three times each
Over ambient temperature range -25 to +70 ℃ -13 to +158℉ : within plus or minus10 % of sensing range at +20 ℃ +68℉
Within plus or minus2 % for plus or minus10 % fluctuation of the supply voltage
7 mm 0.276 in plus or minus 10 % (Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 5.6 mm 0 to 0.220 in (Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 18 × 18 × t 1 mm 0.709 × 0.709 × t 0.039 in
20 % or less of operation distance (with standard sensing object)
12 to 24 V DC +10 /-15 % Ripple P-P 10 % or less
0.8 mA or less (Note) It is the leakage current when the output is in the OFF state.
Non-contact DC 2-wire type - Load current: 3 to 70 mA (Note 1) - Residual voltage: 3 V or less (Note 2) (Note 1) The maximum load current varies depending on the ambient temperature. (Note 2) When the cable is extended, the residual voltage becomes larger.
Incorporated
500 Hz
Orange LED (lights up when the output is ON)
IP67 (IEC), IP67g (JEM) (Note:If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil.
Please check the resistivity of the sensor against the cutting oil you are using beforehand.)
-25 to +70 ℃ -13 to +158℉, Storage: -30 to +80 ℃ -22 to +176℉
45 to 85 % RH, Storage: 35 to 95 % RH
1,000 V AC for one min. between all supply terminals connected together and enclosure
50 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions three times each
Over ambient temperature range -25 to +70 ℃ -13 to +158℉ : within plus or minus10 % of sensing range at +20 ℃ +68℉
Within plus or minus2 % for plus or minus10 % fluctuation of the supply voltage
15 mm 0.591 in plus or minus 10 % (Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 12 mm 0 to 0.472 in (Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 50 × 50 × t 1 mm 1.969 × 1.969 × t 0.039 in
20 % or less of operation distance (with standard sensing object)
12 to 24 V DC +10 /-15 % Ripple P-P 10 % or less
0.8 mA or less (Note) It is the leakage current when the output is in the OFF state.
Non-contact DC 2-wire type - Load current: 3 to 70 mA (Note 1) - Residual voltage: 3 V or less (Note 2) (Note 1) The maximum load current varies depending on the ambient temperature. (Note 2) When the cable is extended, the residual voltage becomes larger.
Incorporated
350 Hz
Normally closed type: Orange LED (lights up when the output is ON)
Lights up in green under stable sensing condition lights up in orange under unstable sensing condition
IP67 (IEC), IP67g (JEM) (Note:If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil.
Please check the resistivity of the sensor against the cutting oil you are using beforehand.)
-25 to +70 ℃ -13 to +158℉, Storage: -30 to +80 ℃ -22 to +176℉
45 to 85 % RH, Storage: 35 to 95 % RH
1,000 V AC for one min. between all supply terminals connected together and enclosure
50 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions three times each
Over ambient temperature range -25 to +70 ℃ -13 to +158℉ : within plus or minus10 % of sensing range at +20 ℃ +68℉
Within plus or minus2 % for plus or minus10 % fluctuation of the supply voltage
15 mm 0.591 in plus or minus 10 % (Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 12 mm 0 to 0.472 in (Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 50 × 50 × t 1 mm 1.969 × 1.969 × t 0.039 in
20 % or less of operation distance (with standard sensing object)
12 to 24 V DC +10 /-15 % Ripple P-P 10 % or less
0.8 mA or less (Note) It is the leakage current when the output is in the OFF state.
Non-contact DC 2-wire type - Load current: 3 to 70 mA (Note 1) - Residual voltage: 3 V or less (Note 2) (Note 1) The maximum load current varies depending on the ambient temperature. (Note 2) When the cable is extended, the residual voltage becomes larger.
Incorporated
350 Hz
Normally closed type: Orange LED (lights up when the output is ON)
Lights up in green under stable sensing condition lights up in orange under unstable sensing condition
IP67 (IEC), IP67g (JEM) (Note:If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil.
Please check the resistivity of the sensor against the cutting oil you are using beforehand.)
-25 to +70 ℃ -13 to +158℉, Storage: -30 to +80 ℃ -22 to +176℉
45 to 85 % RH, Storage: 35 to 95 % RH
1,000 V AC for one min. between all supply terminals connected together and enclosure
50 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions three times each
Over ambient temperature range -25 to +70 ℃ -13 to +158℉ : within plus or minus10 % of sensing range at +20 ℃ +68℉
Within plus or minus2 % for plus or minus10 % fluctuation of the supply voltage
15 mm 0.591 in plus or minus 10 % (Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 12 mm 0 to 0.472 in (Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 50 × 50 × t 1 mm 1.969 × 1.969 × t 0.039 in
20 % or less of operation distance (with standard sensing object)
12 to 24 V DC +10 /-15 % Ripple P-P 10 % or less
0.8 mA or less (Note) It is the leakage current when the output is in the OFF state.
Non-contact DC 2-wire type - Load current: 3 to 70 mA (Note 1) - Residual voltage: 3 V or less (Note 2) (Note 1) The maximum load current varies depending on the ambient temperature. (Note 2) When the cable is extended, the residual voltage becomes larger.
Incorporated
350 Hz
Orange LED (lights up when the output is ON)
IP67 (IEC), IP67g (JEM) (Note:If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil.
Please check the resistivity of the sensor against the cutting oil you are using beforehand.)
-25 to +70 ℃ -13 to +158℉, Storage: -30 to +80 ℃ -22 to +176℉
45 to 85 % RH, Storage: 35 to 95 % RH
1,000 V AC for one min. between all supply terminals connected together and enclosure
50 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions three times each
Over ambient temperature range -25 to +70 ℃ -13 to +158℉ : within plus or minus10 % of sensing range at +20 ℃ +68℉
Within plus or minus2 % for plus or minus10 % fluctuation of the supply voltage