-10 to +60 ℃ -14 to +140 ℉ (No dew condensation or icing allowed), Storage: -10 to +60 ℃ -14 to +140 ℉
35 to 85 % RH, Storage: 35 to 85 % RH
Cover: ABS, Terminal part: PBT
75 g approx.
Adjusting screwdriver: 1 pc.
10 to 28 V DC
20 mA approx.
NPN open-collector transistor - Maximum sink current: 200 mA - Applied voltage: 30 V DC or less (between output and 0 V) - Residual voltage: 1.5 V or less (at 200 mA sink current), 0.4 V or less (at 16 mA sink current) PNP open-collector transistor - Maximum source current: 200 mA - Residual voltage: 1.5 V or less (at 200 mA source current)
Selectable either Normally open or Normally closed
2 mm 0.079 in (Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 0.8 mm 0 to 0.031 in (Note) The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 18 × 18 × t1 mm 0.709 × 0.709 × t0.039 in
50 μm 1.969 mil or less
2 μm 0.079 mil or less (Note) The repeatability is given for the stable sensing range. (along sensing axis, perpendicular to sensing axis)
IP67 (IEC)
–10 to +60 ℃ 14 to +140 ℉, Storage: –10 to +60 ℃ 14 to +140 ℉
35 to 95 % RH, Storage: 35 to 95 % RH
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each
Oil-resistant high frequency coaxial cable, 3 m 9.843 ft long (intrinsic impedance: 50Ω) (Note):If the cable of the sensor head is cut or extended, the sensing range and the hysteresis change.
Extension up to total 8 m 26.247 ft is possible with an equivalent cable (Note):If the cable of the sensor head is cut or extended, the sensing range and the hysteresis change.
35 g approx. (Note) The weight of the threaded type includes the weight of two nuts and one toothed lock washer.
8 mm 0.315 in (Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 5 mm 0 to 0.197 in (Note) The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 18 × 18 × t1 mm 0.709 × 0.709 × t0.039 in
70 μm 2.756 mil or less
5 μm 0.197 mil or lesss (Note) The repeatability is given for the stable sensing range. (along sensing axis, perpendicular to sensing axis)
IP67 (IEC)
–10 to +60 ℃ 14 to +140 ℉, Storage: –10 to +60 ℃ 14 to +140 ℉
35 to 95 % RH, Storage: 35 to 95 % RH
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each
Oil-resistant high frequency coaxial cable, 3 m 9.843 ft long (intrinsic impedance: 50Ω) (Note):If the cable of the sensor head is cut or extended, the sensing range and the hysteresis change.
Extension up to total 8 m 26.247 ft is possible with an equivalent cable (Note):If the cable of the sensor head is cut or extended, the sensing range and the hysteresis change.
46 g approx. (Note) The weight of the threaded type includes the weight of two nuts and one toothed lock washer.
4 mm 0.157 in (Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 2 mm 0 to 0.079 in (Note) The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 18 × 18 × t1 mm 0.709 × 0.709 × t0.039 in
50 μm 1.969 mil or less
5 μm 0.197 mil or less (Note) The repeatability is given for the stable sensing range. (along sensing axis, perpendicular to sensing axis)
IP67 (IEC)
–10 to +60 ℃ 14 to +140 ℉, Storage: –10 to +60 ℃ 14 to +140 ℉
35 to 95 % RH, Storage: 35 to 95 % RH
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each
Oil-resistant high frequency coaxial cable, 3 m 9.843 ft long (intrinsic impedance: 50Ω) (Note):If the cable of the sensor head is cut or extended, the sensing range and the hysteresis change.
Extension up to total 8 m 26.247 ft is possible with an equivalent cable (Note):If the cable of the sensor head is cut or extended, the sensing range and the hysteresis change.
45 g approx. (Note) The weight of the threaded type includes the weight of two nuts and one toothed lock washer.
6 mm 0.236 in (Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 3 mm 0 to 0.118 in (Note) The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 18 × 18 × t1 mm 0.709 × 0.709 × t0.039 in
60 μm 2.362 mil or less
5 μm 0.197 mil or less (Note) The repeatability is given for the stable sensing range. (along sensing axis, perpendicular to sensing axis)
IP67 (IEC)
–10 to +60 ℃ 14 to +140 ℉, Storage: –10 to +60 ℃ 14 to +140 ℉
35 to 95 % RH, Storage: 35 to 95 % RH
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each
Oil-resistant high frequency coaxial cable, 3 m 9.843 ft long (intrinsic impedance: 50Ω) (Note):If the cable of the sensor head is cut or extended, the sensing range and the hysteresis change.
Extension up to total 8 m 26.247 ft is possible with an equivalent cable (Note):If the cable of the sensor head is cut or extended, the sensing range and the hysteresis change.
50 g approx. (Note) The weight of the threaded type includes the weight of two nuts and one toothed lock washer.
3.5 mm 0.138 in (Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 1.5 mm 0 to 0.059 in (Note) The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 18 × 18 × t1 mm 0.709 × 0.709 × t0.039 in
50 μm 1.969 mil or less
3μm 0.118 mil or less (Note) The repeatability is given for the stable sensing range. (along sensing axis, perpendicular to sensing axis)
IP67 (IEC)
–10 to +60 ℃ 14 to +140 ℉, Storage: –10 to +60 ℃ 14 to +140 ℉
35 to 95 % RH, Storage: 35 to 95 % RH
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each
Oil-resistant high frequency coaxial cable, 3 m 9.843 ft long (intrinsic impedance: 50Ω) (Note):If the cable of the sensor head is cut or extended, the sensing range and the hysteresis change.
Extension up to total 8 m 26.247 ft is possible with an equivalent cable (Note):If the cable of the sensor head is cut or extended, the sensing range and the hysteresis change.
44 g approx. (Note) The weight of the threaded type includes the weight of two nuts and one toothed lock washer.
4 mm 0.157 in (Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 2 mm 0 to 0.079 in (Note) The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 18 × 18 × t1 mm 0.709 × 0.709 × t0.039 in
50 μm 1.969 mil or less
5 μm 0.197 mil or less (Note) The repeatability is given for the stable sensing range. (along sensing axis, perpendicular to sensing axis)
IP67 (IEC)
–10 to +60 ℃ 14 to +140 ℉, Storage: –10 to +60 ℃ 14 to +140 ℉
35 to 95 % RH, Storage: 35 to 95 % RH
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each
Oil-resistant high frequency coaxial cable, 3 m 9.843 ft long (intrinsic impedance: 50Ω) (Note):If the cable of the sensor head is cut or extended, the sensing range and the hysteresis change.
Extension up to total 8 m 26.247 ft is possible with an equivalent cable (Note):If the cable of the sensor head is cut or extended, the sensing range and the hysteresis change.
37 g approx. (Note) The weight of the threaded type includes the weight of two nuts and one toothed lock washer.
3 mm 0.118 in (Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 1mm 0 to 0.039 in (Note) The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 18 × 18 × t1 mm 0.709 × 0.709 × t0.039 in
50 μm 1.969 mil or less
2.5 μm 0.098 mil or less (Note) The repeatability is given for the stable sensing range. (along sensing axis, perpendicular to sensing axis)
IP67 (IEC)
–10 to +60 ℃ 14 to +140 ℉, Storage: –10 to +60 ℃ 14 to +140 ℉
35 to 95 % RH, Storage: 35 to 95 % RH
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each
Oil-resistant high frequency coaxial cable, 3 m 9.843 ft long (intrinsic impedance: 50Ω) (Note):If the cable of the sensor head is cut or extended, the sensing range and the hysteresis change.
Extension up to total 8 m 26.247 ft is possible with an equivalent cable (Note):If the cable of the sensor head is cut or extended, the sensing range and the hysteresis change.
36 g approx. (Note) The weight of the threaded type includes the weight of two nuts and one toothed lock washer.
8 mm 0.315 in (Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 5 mm 0 to 0.197 in (Note) The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 18 × 18 × t1 mm 0.709 × 0.709 × t0.039 in
70 μm 2.756 mil or less
5 μm 0.197 mil or less (Note) The repeatability is given for the stable sensing range. (along sensing axis, perpendicular to sensing axis)
IP67 (IEC)
–10 to +60 ℃ 14 to +140 ℉, Storage: –10 to +60 ℃ 14 to +140 ℉
35 to 95 % RH, Storage: 35 to 95 % RH
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each
Oil-resistant high frequency coaxial cable, 3 m 9.843 ft long (intrinsic impedance: 50Ω) (Note):If the cable of the sensor head is cut or extended, the sensing range and the hysteresis change.
Extension up to total 8 m 26.247 ft is possible with an equivalent cable (Note):If the cable of the sensor head is cut or extended, the sensing range and the hysteresis change.
53 g approx. (Note) The weight of the threaded type includes the weight of two nuts and one toothed lock washer.
Nut: 2 pcs. Toolhed lock washer: 1 pc.
Models table for series Compact Micro-size Inductive Proximity Sensor GS
-10 to +60 ℃ -14 to +140 ℉ (No dew condensation or icing allowed), Storage: -10 to +60 ℃ -14 to +140 ℉
35 to 85 % RH, Storage: 35 to 85 % RH
Cover: ABS, Terminal part: PBT
75 g approx.
Adjusting screwdriver: 1 pc.
10 to 28 V DC
20 mA approx.
NPN open-collector transistor - Maximum sink current: 200 mA - Applied voltage: 30 V DC or less (between output and 0 V) - Residual voltage: 1.5 V or less (at 200 mA sink current), 0.4 V or less (at 16 mA sink current) PNP open-collector transistor - Maximum source current: 200 mA - Residual voltage: 1.5 V or less (at 200 mA source current)
Selectable either Normally open or Normally closed
2 mm 0.079 in (Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 0.8 mm 0 to 0.031 in (Note) The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 18 × 18 × t1 mm 0.709 × 0.709 × t0.039 in
50 μm 1.969 mil or less
2 μm 0.079 mil or less (Note) The repeatability is given for the stable sensing range. (along sensing axis, perpendicular to sensing axis)
IP67 (IEC)
–10 to +60 ℃ 14 to +140 ℉, Storage: –10 to +60 ℃ 14 to +140 ℉
35 to 95 % RH, Storage: 35 to 95 % RH
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each
Oil-resistant high frequency coaxial cable, 3 m 9.843 ft long (intrinsic impedance: 50Ω) (Note):If the cable of the sensor head is cut or extended, the sensing range and the hysteresis change.
Extension up to total 8 m 26.247 ft is possible with an equivalent cable (Note):If the cable of the sensor head is cut or extended, the sensing range and the hysteresis change.
35 g approx. (Note) The weight of the threaded type includes the weight of two nuts and one toothed lock washer.
8 mm 0.315 in (Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 5 mm 0 to 0.197 in (Note) The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 18 × 18 × t1 mm 0.709 × 0.709 × t0.039 in
70 μm 2.756 mil or less
5 μm 0.197 mil or lesss (Note) The repeatability is given for the stable sensing range. (along sensing axis, perpendicular to sensing axis)
IP67 (IEC)
–10 to +60 ℃ 14 to +140 ℉, Storage: –10 to +60 ℃ 14 to +140 ℉
35 to 95 % RH, Storage: 35 to 95 % RH
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each
Oil-resistant high frequency coaxial cable, 3 m 9.843 ft long (intrinsic impedance: 50Ω) (Note):If the cable of the sensor head is cut or extended, the sensing range and the hysteresis change.
Extension up to total 8 m 26.247 ft is possible with an equivalent cable (Note):If the cable of the sensor head is cut or extended, the sensing range and the hysteresis change.
46 g approx. (Note) The weight of the threaded type includes the weight of two nuts and one toothed lock washer.
4 mm 0.157 in (Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 2 mm 0 to 0.079 in (Note) The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 18 × 18 × t1 mm 0.709 × 0.709 × t0.039 in
50 μm 1.969 mil or less
5 μm 0.197 mil or less (Note) The repeatability is given for the stable sensing range. (along sensing axis, perpendicular to sensing axis)
IP67 (IEC)
–10 to +60 ℃ 14 to +140 ℉, Storage: –10 to +60 ℃ 14 to +140 ℉
35 to 95 % RH, Storage: 35 to 95 % RH
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each
Oil-resistant high frequency coaxial cable, 3 m 9.843 ft long (intrinsic impedance: 50Ω) (Note):If the cable of the sensor head is cut or extended, the sensing range and the hysteresis change.
Extension up to total 8 m 26.247 ft is possible with an equivalent cable (Note):If the cable of the sensor head is cut or extended, the sensing range and the hysteresis change.
45 g approx. (Note) The weight of the threaded type includes the weight of two nuts and one toothed lock washer.
6 mm 0.236 in (Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 3 mm 0 to 0.118 in (Note) The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 18 × 18 × t1 mm 0.709 × 0.709 × t0.039 in
60 μm 2.362 mil or less
5 μm 0.197 mil or less (Note) The repeatability is given for the stable sensing range. (along sensing axis, perpendicular to sensing axis)
IP67 (IEC)
–10 to +60 ℃ 14 to +140 ℉, Storage: –10 to +60 ℃ 14 to +140 ℉
35 to 95 % RH, Storage: 35 to 95 % RH
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each
Oil-resistant high frequency coaxial cable, 3 m 9.843 ft long (intrinsic impedance: 50Ω) (Note):If the cable of the sensor head is cut or extended, the sensing range and the hysteresis change.
Extension up to total 8 m 26.247 ft is possible with an equivalent cable (Note):If the cable of the sensor head is cut or extended, the sensing range and the hysteresis change.
50 g approx. (Note) The weight of the threaded type includes the weight of two nuts and one toothed lock washer.
3.5 mm 0.138 in (Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 1.5 mm 0 to 0.059 in (Note) The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 18 × 18 × t1 mm 0.709 × 0.709 × t0.039 in
50 μm 1.969 mil or less
3μm 0.118 mil or less (Note) The repeatability is given for the stable sensing range. (along sensing axis, perpendicular to sensing axis)
IP67 (IEC)
–10 to +60 ℃ 14 to +140 ℉, Storage: –10 to +60 ℃ 14 to +140 ℉
35 to 95 % RH, Storage: 35 to 95 % RH
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each
Oil-resistant high frequency coaxial cable, 3 m 9.843 ft long (intrinsic impedance: 50Ω) (Note):If the cable of the sensor head is cut or extended, the sensing range and the hysteresis change.
Extension up to total 8 m 26.247 ft is possible with an equivalent cable (Note):If the cable of the sensor head is cut or extended, the sensing range and the hysteresis change.
44 g approx. (Note) The weight of the threaded type includes the weight of two nuts and one toothed lock washer.
4 mm 0.157 in (Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 2 mm 0 to 0.079 in (Note) The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 18 × 18 × t1 mm 0.709 × 0.709 × t0.039 in
50 μm 1.969 mil or less
5 μm 0.197 mil or less (Note) The repeatability is given for the stable sensing range. (along sensing axis, perpendicular to sensing axis)
IP67 (IEC)
–10 to +60 ℃ 14 to +140 ℉, Storage: –10 to +60 ℃ 14 to +140 ℉
35 to 95 % RH, Storage: 35 to 95 % RH
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each
Oil-resistant high frequency coaxial cable, 3 m 9.843 ft long (intrinsic impedance: 50Ω) (Note):If the cable of the sensor head is cut or extended, the sensing range and the hysteresis change.
Extension up to total 8 m 26.247 ft is possible with an equivalent cable (Note):If the cable of the sensor head is cut or extended, the sensing range and the hysteresis change.
37 g approx. (Note) The weight of the threaded type includes the weight of two nuts and one toothed lock washer.
3 mm 0.118 in (Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 1mm 0 to 0.039 in (Note) The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 18 × 18 × t1 mm 0.709 × 0.709 × t0.039 in
50 μm 1.969 mil or less
2.5 μm 0.098 mil or less (Note) The repeatability is given for the stable sensing range. (along sensing axis, perpendicular to sensing axis)
IP67 (IEC)
–10 to +60 ℃ 14 to +140 ℉, Storage: –10 to +60 ℃ 14 to +140 ℉
35 to 95 % RH, Storage: 35 to 95 % RH
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each
Oil-resistant high frequency coaxial cable, 3 m 9.843 ft long (intrinsic impedance: 50Ω) (Note):If the cable of the sensor head is cut or extended, the sensing range and the hysteresis change.
Extension up to total 8 m 26.247 ft is possible with an equivalent cable (Note):If the cable of the sensor head is cut or extended, the sensing range and the hysteresis change.
36 g approx. (Note) The weight of the threaded type includes the weight of two nuts and one toothed lock washer.
8 mm 0.315 in (Note) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
0 to 5 mm 0 to 0.197 in (Note) The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
Iron sheet 18 × 18 × t1 mm 0.709 × 0.709 × t0.039 in
70 μm 2.756 mil or less
5 μm 0.197 mil or less (Note) The repeatability is given for the stable sensing range. (along sensing axis, perpendicular to sensing axis)
IP67 (IEC)
–10 to +60 ℃ 14 to +140 ℉, Storage: –10 to +60 ℃ 14 to +140 ℉
35 to 95 % RH, Storage: 35 to 95 % RH
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each
Oil-resistant high frequency coaxial cable, 3 m 9.843 ft long (intrinsic impedance: 50Ω) (Note):If the cable of the sensor head is cut or extended, the sensing range and the hysteresis change.
Extension up to total 8 m 26.247 ft is possible with an equivalent cable (Note):If the cable of the sensor head is cut or extended, the sensing range and the hysteresis change.
53 g approx. (Note) The weight of the threaded type includes the weight of two nuts and one toothed lock washer.
Nut: 2 pcs. Toolhed lock washer: 1 pc.
You May Also Be Interested In Time of Flight (ToF) Camera Sensors
Instantly Detect Distance With Time of Flight (ToF) Camera Sensors
Panasonic Time of Flight (ToF) Cameras are compact, real-time, sensing cameras based on the ToF principle. Available in indoor and outdoor models, these cameras instantly detect distance between the camera and the targeted object with depth, infrared, and color (RGB) images. The GC1 indoor model produces RGB (640x480), depth map (320x240) (640x480) images. As well, engineers no longer need separate cameras for the depth, IR, and color images with 14/16/36 bit data formats. The HC4W outdoor model has a wide 90° FOV and is used in various applications such as security, autonomous vehicles and robotics.