Specifications
Item | Performance characteristics |
---|---|
CE Marking Directive Compliance | EMC Directive, RoHS Directive |
Pollution Degree | 3 (Industrial environment) |
Ambient Temperature | 0 to +40 ℃ +32 to +104℉ (No dew condensation), Storage: -20 to +70 ℃ -4 to +158℉ |
Ambient Humidity | 35 to 85 % RH, Storage: 35 to 85 % RH |
Voltage Withstandability | 1,000 V AC for one min. between all supply terminals connected together and enclosure |
Insulation Resistance | 20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure |
Vibration Resistance | 10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each |
Shock Resistance | 490 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each |
Material | Enclosure: Heat-resistant ABS, Connector cover: Heat-resistant ABS, Adjuster cover: Polycarbonate |
Cable | 0.22 mm2 3-core heat-resistant PVC cable, 0.3 m 0.984 ft long |
Weight (Typ.) | Net weight: 85 g approx. |
Applicable Sensor Head | HD-T1030 |
Supply Voltage | 24 V DC ± 10 % Ripple P-P 10 % or less |
Current Consumption | 70 mA or less (Including sensor head) |
Analog Output | Analog voltage - Output voltage: 1 ± 0.5 V (all light interrupted) to 5 ± 0.5 V (all light received) - Output impedance: 75 Ω |
Analog Output: Response Time | 0.5 ms or less (8 V/ms or more) |
Analog Output: Resolution | 30 μm 1.181 mil (Note):Resolution refers to the peak to peak distance conversion value of analog output (in the frequency band below 20 MHz). |
Analog Output: Linearity | ±1.0 % F.S. (at 28 mm 1.102 in sensing width of the sensing center) (Note):This is the representative example of measurement with a combination of sensor head and controller. |
Analog Output:Temperature Characteristics | ±0.1 % F.S./℃ (at 24 ± 2 ℃ 75.2 ± 35.6℉) (Note):This is the representative example of measurement with a combination of sensor head and controller. |
Span Adjustment Function | Span of the analog output voltage is adjusted. 15-turn endless adjuster |
Shift Adjustment Function | Offset of the analog output voltage is adjusted. 15-turn endless adjuster |
Warming-Up Period | 30 min. or more |
Cable Extension | Extension up to total 3 m 9.843 ft is possible with 0.3 mm2, or more, heat-resistant PVC cable. |