Amplifier Built-in Ultra-compact Laser Sensor EX-L200

The EX-L200, the one of the world’s smallest Laser Sensors with a built-in amplifier, is designed to detect minute objects with utmost accuracy. Despite its miniature size, the Thru-Beam Type (EX-L211) can detect minute objects with a diameter of just 0.3mm, and the Spot Reflective Type (EX-L221) can even detect gold wire whose diameter is a mere 0.01mm. To facilitate solving application tasks, these sensors come equipped with a Potentiometer and two indicator LEDs. For the Thru-Beam Type, reflective material on the receiver allows users to visualize the laser beam, easing beam-axis alignment.

Characteristics:

  • Miniature Design
  • Response Time Only 0.5ms
  • Visible Red Laser Diode
  • Sensitivity Adjuster
  • Available As Thru-Beam, Retroreflective And Spot Reflective Types
  • Line Spot Type
  • IP67 Degree Of Protection
  • 2 Indicator LEDs

Part Number List

Results 42
Models table for series Amplifier Built-in Ultra-compact Laser Sensor EX-L200
Part No.DatasheetCE Marking Directive ComplianceSensing Range Emission Spot Size (Typical)Sensing Object Minimum Sensing Object (Typical)HysteresisRepeatabilityRepeatability (Typical) (Perpendicular to Sensing Axis)Supply Voltage Current ConsumptionOutputOutput: Output Operation Output: Short-Circuit ProtectionResponse TimeOperation Indicator Stability IndicatorPower Indicator Automatic Interference Prevention FunctionSensitivity AdjusterProtectionAmbient TemperatureAmbient HumidityAmbient IlluminanceVoltage WithstandabilityInsulation Resistance Vibration ResistanceShock ResistanceEmitting ElementMaterialCableCable ExtensionWeight (Typ.)Accessory
EMC Directive, RoHS Directive
1 m 3.281 ft
Approx. 6 × 4 mm 0.236 × 0.157 in (vertical × horizontal)
(at a sensing distance of 1 m)
Opaque object of ø2 mm ø0.079 in or more
Opaque object of ø0.3 mm ø0.012 in
(Note)Typical values when the sensitivity adjuster is optimally adjusted.
Perpendicular to sensing axis: 0.05 mm 0.0020 in or less
0.01 mm 0.0004 in or less
(all area)
(Note)Typical values when the sensitivity adjuster is optimally adjusted.
12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less
Emitter: 10 mA or less
Receiver: 10 mA or less
PNP open-collector transistor
- Maximum source current: 50 mA
- Applied voltage: 26.4 V DC or less (between output and +V)
- Residual voltage: 2 V or less (at 50 mA source current), 1 V or less (at 16 mA source current)
Light-ON / Dark-ON selectable by the output operation switching input
Incorporated (short-circuit protection / inverse polarity protection)
0.5 ms or less
Orange LED (lights up when the output is ON) (incorporated on the receiver for thru-beam type)
Green LED (lights up under stable light received condition or stable dark condition) (incorporated on the receiver for thru-beam type)
Green LED (lights up when the power is ON) (incorporated on the emitter)
Continuously variable adjuster (incorporated on the receiver)
IP67 (IEC)
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or no icing condition),
Storage: -30 to +70 ℃ -22 to +158 ℉
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 3,000 lx or less at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 500 Hz frequency, 1.5 mm 0.059 in double amplitude (10 G max.) in X, Y and Z directions for two hours each
500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each
Red semiconductor laser Class 1 (IEC / JIS/ FDA/ GB) (Note:This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 56, dated May 8, 2019, issued by CDRH
(Center for Devices and Radiological Health) under the FDA (Food and Drug Administration)
(Maximum output: 390 μW, Peak emission wavelength: 655 nm 0.026 mil)
Enclosure: Polybutylene terephthalate, Front cover: Acylic, Lens: Glass, Indicator part: Polyarylate
0.15 mm2 4-core (emitter of a thru-beam type: 2-core) cabtyre cable, 2 m 6.562 ft long
Extension up to total 50 m 164.042 ft is possible with 0.3 mm2, or more, cable (thru-beam type: Total 100 m 328.084 ft both emitter and receiver).
Net weight: Emitter: 40 g approx., Receiver: 40 g approx.,
Gross weight: 90 g approx.
MS-EXL2-2 (Mounting plate): 2 pcs.
EMC Directive, RoHS Directive
1 m 3.281 ft
Approx. 6 × 4 mm 0.236 × 0.157 in (vertical × horizontal)
(at a sensing distance of 1 m)
Opaque object of ø2 mm ø0.079 in or more
Opaque object of ø0.3 mm ø0.012 in
(Note)Typical values when the sensitivity adjuster is optimally adjusted.
Perpendicular to sensing axis: 0.05 mm 0.0020 in or less
0.01 mm 0.0004 in or less
(all area)
(Note)Typical values when the sensitivity adjuster is optimally adjusted.
12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less
Emitter: 10 mA or less
Receiver: 10 mA or less
NPN open-collector transistor
- Maximum sink current: 50 mA
- Applied voltage: 26.4 V DC or less (between output and 0 V)
- Residual voltage: 2 V or less (at 50 mA sink current), 1 V or less (at 16 mA sink current)
Light-ON / Dark-ON selectable by the output operation switching input
Incorporated (short-circuit protection / inverse polarity protection)
0.5 ms or less
Orange LED (lights up when the output is ON) (incorporated on the receiver for thru-beam type)
Green LED (lights up under stable light received condition or stable dark condition) (incorporated on the receiver for thru-beam type)
Green LED (lights up when the power is ON) (incorporated on the emitter)
Continuously variable adjuster (incorporated on the receiver)
IP67 (IEC)
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or no icing condition),
Storage: -30 to +70 ℃ -22 to +158 ℉
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 3,000 lx or less at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 500 Hz frequency, 1.5 mm 0.059 in double amplitude (10 G max.) in X, Y and Z directions for two hours each
500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each
Red semiconductor laser Class 1 (IEC / JIS/ FDA/ GB) (Note:This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 56, dated May 8, 2019, issued by CDRH
(Center for Devices and Radiological Health) under the FDA (Food and Drug Administration)
(Maximum output: 390 μW, Peak emission wavelength: 655 nm 0.026 mil)
Enclosure: Polybutylene terephthalate, Front cover: Acylic, Lens: Glass, Indicator part: Polyarylate
0.15 mm2 4-core (emitter of a thru-beam type: 2-core) cabtyre cable, 2 m 6.562 ft long
Extension up to total 50 m 164.042 ft is possible with 0.3 mm2, or more, cable (thru-beam type: Total 100 m 328.084 ft both emitter and receiver).
Net weight: Emitter: 40 g approx., Receiver: 40 g approx.,
Gross weight: 90 g approx.
MS-EXL2-2 (Mounting plate): 2 pcs.
EMC Directive, RoHS Directive
3 m 9.843 ft
Approx. 8 × 5.5 mm 0.315 × 0.217 in (vertical × horizontal)
(at a sensing distance of 1 m)
(Note) In the case sensing distance is 3 m 9.843 ft, the emission spot size is H 17 × W 11 mm H 0.669 × W 0.433 in (visual reference value).
Opaque object of ø3 mm ø0.118 in or more
-
Perpendicular to sensing axis: 0.05 mm 0.0020 in or less
-
12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less
Emitter: 10 mA or less
Receiver: 10 mA or less
NPN open-collector transistor
- Maximum sink current: 50 mA
- Applied voltage: 26.4 V DC or less (between output and 0 V)
- Residual voltage: 2 V or less (at 50 mA sink current), 1 V or less (at 16 mA sink current)
Light-ON / Dark-ON selectable by the output operation switching input
Incorporated (short-circuit protection / inverse polarity protection)
0.5 ms or less
Orange LED (lights up when the output is ON) (incorporated on the receiver for thru-beam type)
Green LED (lights up under stable light received condition or stable dark condition) (incorporated on the receiver for thru-beam type)
-
-
IP67 (IEC)
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or no icing condition),
Storage: -30 to +70 ℃ -22 to +158 ℉
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 3,000 lx or less at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 500 Hz frequency, 1.5 mm 0.059 in double amplitude (10 G max.) in X, Y and Z directions for two hours each
500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each
Red semiconductor laser Class 1 (IEC / JIS/ FDA/ GB) (Note:This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 56, dated May 8, 2019, issued by CDRH
(Center for Devices and Radiological Health) under the FDA (Food and Drug Administration)
(Maximum output: 390 μW, Peak emission wavelength: 655 nm 0.026 mil)
Enclosure: Polybutylene terephthalate, Front cover: Acylic, Lens: Glass, Indicator part: Polyarylate
0.15 mm2 4-core (emitter of a thru-beam type: 2-core) cabtyre cable, 2 m 6.562 ft long
Net weight: Emitter: 40 g approx., Receiver: 40 g approx.,
Gross weight: 90 g approx.
MS-EXL2-2 (Mounting plate): 2 pcs.
EMC Directive, RoHS Directive
1 m 3.281 ft
Approx. 6 × 4 mm 0.236 × 0.157 in (vertical × horizontal)
(at a sensing distance of 1 m)
Opaque object of ø2 mm ø0.079 in or more
Opaque object of ø0.3 mm ø0.012 in
(Note)Typical values when the sensitivity adjuster is optimally adjusted.
Perpendicular to sensing axis: 0.05 mm 0.0020 in or less
0.01 mm 0.0004 in or less
(all area)
(Note)Typical values when the sensitivity adjuster is optimally adjusted.
12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less
Emitter: 10 mA or less
Receiver: 10 mA or less
PNP open-collector transistor
- Maximum source current: 50 mA
- Applied voltage: 26.4 V DC or less (between output and +V)
- Residual voltage: 2 V or less (at 50 mA source current), 1 V or less (at 16 mA source current)
Light-ON / Dark-ON selectable by the output operation switching input
Incorporated (short-circuit protection / inverse polarity protection)
0.5 ms or less
Orange LED (lights up when the output is ON) (incorporated on the receiver for thru-beam type)
Green LED (lights up under stable light received condition or stable dark condition) (incorporated on the receiver for thru-beam type)
Green LED (lights up when the power is ON) (incorporated on the emitter)
Continuously variable adjuster (incorporated on the receiver)
IP67 (IEC)
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or no icing condition),
Storage: -30 to +70 ℃ -22 to +158 ℉
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 3,000 lx or less at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 500 Hz frequency, 1.5 mm 0.059 in double amplitude (10 G max.) in X, Y and Z directions for two hours each
500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each
Red semiconductor laser Class 1 (IEC / JIS/ FDA/ GB) (Note:This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 56, dated May 8, 2019, issued by CDRH
(Center for Devices and Radiological Health) under the FDA (Food and Drug Administration)
(Maximum output: 390 μW, Peak emission wavelength: 655 nm 0.026 mil)
Enclosure: Polybutylene terephthalate, Front cover: Acylic, Lens: Glass, Indicator part: Polyarylate
MS-EXL2-2 (Mounting plate): 2 pcs.
EMC Directive, RoHS Directive
3 m 9.843 ft
Approx. 8 × 5.5 mm 0.315 × 0.217 in (vertical × horizontal)
(at a sensing distance of 1 m)
(Note) In the case sensing distance is 3 m 9.843 ft, the emission spot size is H 17 × W 11 mm H 0.669 × W 0.433 in (visual reference value).
Opaque object of ø3 mm ø0.118 in or more
-
Perpendicular to sensing axis: 0.05 mm 0.0020 in or less
-
12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less
Emitter: 10 mA or less
Receiver: 10 mA or less
PNP open-collector transistor
- Maximum source current: 50 mA
- Applied voltage: 26.4 V DC or less (between output and +V)
- Residual voltage: 2 V or less (at 50 mA source current), 1 V or less (at 16 mA source current)
Light-ON / Dark-ON selectable by the output operation switching input
Incorporated (short-circuit protection / inverse polarity protection)
0.5 ms or less
Orange LED (lights up when the output is ON) (incorporated on the receiver for thru-beam type)
Green LED (lights up under stable light received condition or stable dark condition) (incorporated on the receiver for thru-beam type)
-
-
IP67 (IEC)
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or no icing condition),
Storage: -30 to +70 ℃ -22 to +158 ℉
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 3,000 lx or less at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 500 Hz frequency, 1.5 mm 0.059 in double amplitude (10 G max.) in X, Y and Z directions for two hours each
500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each
Red semiconductor laser Class 1 (IEC / JIS/ FDA/ GB) (Note:This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 56, dated May 8, 2019, issued by CDRH
(Center for Devices and Radiological Health) under the FDA (Food and Drug Administration)
(Maximum output: 390 μW, Peak emission wavelength: 655 nm 0.026 mil)
Enclosure: Polybutylene terephthalate, Front cover: Acylic, Lens: Glass, Indicator part: Polyarylate
0.15 mm2 4-core (emitter of a thru-beam type: 2-core) cabtyre cable, 2 m 6.562 ft long
Net weight: Emitter: 40 g approx., Receiver: 40 g approx.,
Gross weight: 90 g approx.
MS-EXL2-2 (Mounting plate): 2 pcs.
EMC Directive, RoHS Directive
45 to 300 mm 1.772 to 11.811 in
(Note)The sensing range is specified for white non-glossy papar (100 x 100 mm 3.937 x 3.937 in) as the object.
ø1 mm ø0.039 in or less
(at a sensing distance of 300 mm)
ø1 mm ø0.039 in or less
(at a sensing distance of 300 mm)
Gold wire of ø0.01 mm ø0.0004 in
(Note)Typical values when the sensitivity adjuster is optimally adjusted.
20 % or less of operation distance
Perpendicular to sensing axis: 0.05 mm 0.0020 in or less
0.02 mm 0.0008 in or less
(at 100 to 200 mm sensing distance)
(Note)Typical values when the sensitivity adjuster is optimally adjusted.
12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less
15 mA or less
PNP open-collector transistor
- Maximum source current: 50 mA
- Applied voltage: 26.4 V DC or less (between output and +V)
- Residual voltage: 2 V or less (at 50 mA source current), 1 V or less (at 16 mA source current)
Light-ON / Dark-ON selectable by the output operation switching input
Incorporated (short-circuit protection / inverse polarity protection)
0.5 ms or less
Incorporated
(Two sensors can be mounted close together.)
Continuously variable adjuster
IP67 (IEC)
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or no icing condition),
Storage: -30 to +70 ℃ -22 to +158 ℉
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 3,000 lx or less at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 500 Hz frequency, 1.5 mm 0.059 in double amplitude (10 G max.) in X, Y and Z directions for two hours each
500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each
Red semiconductor laser Class 1 (IEC / JIS/ FDA/ GB) (Note:This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 56, dated May 8, 2019, issued by CDRH
(Center for Devices and Radiological Health) under the FDA (Food and Drug Administration)
(Maximum output: 2 mW, Peak emission wavelength: 655 nm 0.026 mil)
Enclosure: Polybutylene terephthalate, Front cover: Acylic, Lens: Glass, Indicator part: Polyarylate
0.15 mm2 4-core (emitter of a thru-beam type: 2-core) cabtyre cable, 2 m 6.562 ft long
Extension up to total 50 m 164.042 ft is possible with 0.3 mm2, or more, cable.
Net weight: 45 g approx
Gross weight: 60 g approx
MS-EXL2-3 (Mounting plate): 1 pc.
EMC Directive, RoHS Directive
3 m 9.843 ft
Approx. 8 × 5.5 mm 0.315 × 0.217 in (vertical × horizontal)
(at a sensing distance of 1 m)
(Note) In the case sensing distance is 3 m 9.843 ft, the emission spot size is H 17 × W 11 mm H 0.669 × W 0.433 in (visual reference value).
Opaque object of ø3 mm ø0.118 in or more
-
Perpendicular to sensing axis: 0.05 mm 0.0020 in or less
-
12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less
Emitter: 10 mA or less
Receiver: 10 mA or less
PNP open-collector transistor
- Maximum source current: 50 mA
- Applied voltage: 26.4 V DC or less (between output and +V)
- Residual voltage: 2 V or less (at 50 mA source current), 1 V or less (at 16 mA source current)
Light-ON / Dark-ON selectable by the output operation switching input
Incorporated (short-circuit protection / inverse polarity protection)
0.5 ms or less
Orange LED (lights up when the output is ON) (incorporated on the receiver for thru-beam type)
Green LED (lights up under stable light received condition or stable dark condition) (incorporated on the receiver for thru-beam type)
-
-
IP67 (IEC)
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or no icing condition),
Storage: -30 to +70 ℃ -22 to +158 ℉
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 3,000 lx or less at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 500 Hz frequency, 1.5 mm 0.059 in double amplitude (10 G max.) in X, Y and Z directions for two hours each
500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each
Red semiconductor laser Class 1 (IEC / JIS/ FDA/ GB) (Note:This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 56, dated May 8, 2019, issued by CDRH
(Center for Devices and Radiological Health) under the FDA (Food and Drug Administration)
(Maximum output: 390 μW, Peak emission wavelength: 655 nm 0.026 mil)
Enclosure: Polybutylene terephthalate, Front cover: Acylic, Lens: Glass, Indicator part: Polyarylate
MS-EXL2-2 (Mounting plate): 2 pcs.
EMC Directive, RoHS Directive
3 m 9.843 ft
Approx. 8 × 5.5 mm 0.315 × 0.217 in (vertical × horizontal)
(at a sensing distance of 1 m)
(Note) In the case sensing distance is 3 m 9.843 ft, the emission spot size is H 17 × W 11 mm H 0.669 × W 0.433 in (visual reference value).
Opaque object of ø3 mm ø0.118 in or more
-
Perpendicular to sensing axis: 0.05 mm 0.0020 in or less
-
12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less
Emitter: 10 mA or less
Receiver: 10 mA or less
NPN open-collector transistor
- Maximum sink current: 50 mA
- Applied voltage: 26.4 V DC or less (between output and 0 V)
- Residual voltage: 2 V or less (at 50 mA sink current), 1 V or less (at 16 mA sink current)
Light-ON / Dark-ON selectable by the output operation switching input
Incorporated (short-circuit protection / inverse polarity protection)
0.5 ms or less
Orange LED (lights up when the output is ON) (incorporated on the receiver for thru-beam type)
Green LED (lights up under stable light received condition or stable dark condition) (incorporated on the receiver for thru-beam type)
-
-
IP67 (IEC)
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or no icing condition),
Storage: -30 to +70 ℃ -22 to +158 ℉
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 3,000 lx or less at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 500 Hz frequency, 1.5 mm 0.059 in double amplitude (10 G max.) in X, Y and Z directions for two hours each
500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each
Red semiconductor laser Class 1 (IEC / JIS/ FDA/ GB) (Note:This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 56, dated May 8, 2019, issued by CDRH
(Center for Devices and Radiological Health) under the FDA (Food and Drug Administration)
(Maximum output: 390 μW, Peak emission wavelength: 655 nm 0.026 mil)
Enclosure: Polybutylene terephthalate, Front cover: Acylic, Lens: Glass, Indicator part: Polyarylate
MS-EXL2-2 (Mounting plate): 2 pcs.
EMC Directive, RoHS Directive
45 to 300 mm 1.772 to 11.811 in
(Note)The sensing range is specified for white non-glossy papar (100 x 100 mm 3.937 x 3.937 in) as the object.
ø1 mm ø0.039 in or less
(at a sensing distance of 300 mm)
ø1 mm ø0.039 in or less
(at a sensing distance of 300 mm)
Gold wire of ø0.01 mm ø0.0004 in
(Note)Typical values when the sensitivity adjuster is optimally adjusted.
20 % or less of operation distance
Perpendicular to sensing axis: 0.05 mm 0.0020 in or less
0.02 mm 0.0008 in or less
(at 100 to 200 mm sensing distance)
(Note)Typical values when the sensitivity adjuster is optimally adjusted.
12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less
15 mA or less
PNP open-collector transistor
- Maximum source current: 50 mA
- Applied voltage: 26.4 V DC or less (between output and +V)
- Residual voltage: 2 V or less (at 50 mA source current), 1 V or less (at 16 mA source current)
Light-ON / Dark-ON selectable by the output operation switching input
Incorporated (short-circuit protection / inverse polarity protection)
0.5 ms or less
Incorporated
(Two sensors can be mounted close together.)
Continuously variable adjuster
IP67 (IEC)
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or no icing condition),
Storage: -30 to +70 ℃ -22 to +158 ℉
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 3,000 lx or less at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 500 Hz frequency, 1.5 mm 0.059 in double amplitude (10 G max.) in X, Y and Z directions for two hours each
500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each
Red semiconductor laser Class 1 (IEC / JIS/ FDA/ GB) (Note:This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 56, dated May 8, 2019, issued by CDRH
(Center for Devices and Radiological Health) under the FDA (Food and Drug Administration)
(Maximum output: 2 mW, Peak emission wavelength: 655 nm 0.026 mil)
Enclosure: Polybutylene terephthalate, Front cover: Acylic, Lens: Glass, Indicator part: Polyarylate
MS-EXL2-3 (Mounting plate): 1 pc.
EMC Directive, RoHS Directive
20 to 50 mm 0.787 to 1.969 in
(Convergent point: 22 mm 0.866 in)
(Note)The sensing range is specified for white non-glossy papar (100 x 100 mm 3.937 x 3.937 in) as the object.
ø1mm 0.039 in
or less (at a sensing distance of 50 mm)
Opaque, translucent or transparent object
(Note)Make sure to confirm detection with an actual sensor before use.
Gold wire of ø0.01 mm ø0.0004 in
(Note) Typical values when the sensitivity adjuster is optimally adjusted.
20 % or less of operation distance
Perpendicular to sensing axis: 0.2 mm 0.0080 in or less
12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less
15 mA or less
PNP open-collector transistor
- Maximum source current: 50 mA
Light-ON / Dark-ON selectable by the output operation switching input
Incorporated (short-circuit protection / inverse polarity protection)
0.5 ms or less
Continuously variable adjuster
IP67(IEC)
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or no icing condition),
Storage: -30 to +70 ℃ -22 to +158 ℉
35 to 85%RH , Storage: 35 to 85%RH
Red semiconductor laser Class 1 (IEC / JIS/ FDA/ GB)
(Note:This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 56, dated May 8, 2019, issued by CDRH
(Center for Devices and Radiological Health) under the FDA (Food and Drug Administration).)
(Maximum output: 1 mW, Peak emission wavelength: 655 nm 0.026 mil)
Enclosure: Polybutylene terephthalate, Front cover: Acylic, Lens: Glass, Indicator part: Polyarylate
0.15 mm2 4-core cabtyre cable, 2 m 6.562 ft long
Extension up to total 50 m 164.042 ft is possible with 0.3 mm2, or more, cable
MS-EXL2-3 (Mounting plate): 1 pc.