GD-20

Specifications

Specifications table for model GD-20
ItemPerformance characteristics
TypeLong sensing range
Applicable ControllerGD-C1, GD-C2
Sensing Range (Between Sensor Heads) 70 mm 2.756 in or less
Detectable Sheet Thickness: Applicable Controllers GD-C3: Setting Distance 35 mm 1.378 inStandard sensing object size: 200 x 200 mm 7.874 x 7.874 in
Iron(SPCC): -
Aluminum: -
Copper: -
Brass: -
Stainless steel (SUS304): -
(Note) The above detectable sheet thicknesses are typical data at the given sensing distance. The allowable thickness will differ from the range described in the above table at other setting distances. Further, double feeds of aluminum foils can also be detected at distances shorter than the above. Please contact our office for details.
Detectable Sheet Thickness: Applicable Controllers GD-C1/C2: Setting Distance 35 mm 1.378 inStandard sensing object size: 200 x 200 mm 7.874 x 7.874 in
Iron(SPCC): 0.07 to 10 mm 0.003 to 0.394 in
Aluminum: 0.03 to 10 mm 0.001 to 0.394 in
Copper: 0.03 to 10 mm 0.001 to 0.394 in
Brass: 0.03 to 10 mm 0.001 to 0.394 in
Stainless steel (SUS304): 0.1 to 10 mm 0.004 to 0.394 in
(Note) The above detectable sheet thicknesses are typical data at the given sensing distance. The allowable thickness will differ from the range described in the above table at other setting distances. Further, double feeds of aluminum foils can also be detected at distances shorter than the above. Please contact our office for details.
Detectable Sheet Thickness: Applicable Controllers GD-C1/C2: Setting Distance 70 mm 2.756 inStandard sensing object size: 200 x 200 mm 7.874 x 7.874 in
Iron(SPCC): 0.07 to 6 mm 0.003 to 0.236 in
Aluminum: 0.03 to 6 mm 0.001 to 0.236 in
Copper: 0.03 to 6 mm 0.001 to 0.236 in
Brass: 0.03 to 6 mm 0.001 to 0.236 in
Stainless steel (SUS304): 0.1 to 6 mm 0.004 to 0.236 in
(Note) The above detectable sheet thicknesses are typical data at the given sensing distance. The allowable thickness will differ from the range described in the above table at other setting distances. Further, double feeds of aluminum foils can also be detected at distances shorter than the above. Please contact our office for details.
Detectable Sheet Thickness: Applicable Controllers GD-C3: Setting Distance 70 mm 2.756 inStandard sensing object size: 200 x 200 mm 7.874 x 7.874 in
Iron(SPCC): -
Aluminum: -
Copper: -
Brass: -
Stainless steel (SUS304): -
(Note) The above detectable sheet thicknesses are typical data at the given sensing distance. The allowable thickness will differ from the range described in the above table at other setting distances. Further, double feeds of aluminum foils can also be detected at distances shorter than the above. Please contact our office for details.
Environmental Resistance: ProtectionIP67 (IEC), IP67G
Environmental Resistance: Ambient Temperature-10 to +60 degrees +14 to +140 degrees Fahrenheit , Storage: -25 to +70 degrees -13 to +158 degrees Fahrenheit
Environmental Resistance: Ambient Humidity45 to 85 % RH, Storage: 35 to 95 % RH
Environmental Resistance: Vibration Resistance10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
Environmental Resistance: Shock Resistance1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions three times each
MaterialSensing face: Polyacetal
Main body: Stainless steel
CableSender: 0.5 2 single core shielded cable, 3 m 9.843 ft long
Receiver: 0.3 2 2-core shielded cable, 3 m 9.843 ft long
Cable ExtensionExtension up to total 20 m 65.617 ft is possible with an equivalent shielded cable.
Weight (Typ.)Net weight: 440 g approx.
Accessory-

Stock check

Model image for GD-20

GD-20