Specifications
Item | Performance characteristics |
---|---|
Type | Small object detection |
Applicable Controller | GD-C3 |
Sensing Range (Between Sensor Heads) | 10 mm 0.394 in or less |
Detectable Sheet Thickness: Applicable Controllers GD-C1/C2: Setting Distance 5 mm 0.197 in | Standard sensing object size: 20 x 20 mm 0.787 x 0.787 in Iron(SPCC): - Aluminum: - Copper: - Brass: - Stainless steel (SUS304): - (Note) The above detectable sheet thicknesses are typical data at the given sensing distance. The allowable thickness will differ from the range described in the above table at other setting distances. Further, double feeds of aluminum foils can also be detected at distances shorter than the above. Please contact our office for details. |
Detectable Sheet Thickness: Applicable Controllers GD-C3: Setting Distance 5 mm 0.197 in | Standard sensing object size: 20 x 20 mm 0.787 x 0.787 in Iron(SPCC): 0.01 to 0.1 mm 0.0004 to 0.004 in Aluminum: 0.015 to 1 mm 0.001 to 0.039 in Copper: 0.018 to 1 mm 0.001 to 0.039 in Brass: 0.03 to 1 mm 0.001 to 0.039 in Stainless steel (SUS304): 0.3 to 1 mm 0.012 to 0.039 in (Note) The above detectable sheet thicknesses are typical data at the given sensing distance. The allowable thickness will differ from the range described in the above table at other setting distances. Further, double feeds of aluminum foils can also be detected at distances shorter than the above. Please contact our office for details. |
Detectable Sheet Thickness: Applicable Controllers GD-C1/C2: Setting Distance 10 mm 0.394 in | Standard sensing object size: 20 x 20 mm 0.787 x 0.787 in Iron(SPCC): - Aluminum: - Copper: - Brass: - Stainless steel (SUS304): - (Note) The above detectable sheet thicknesses are typical data at the given sensing distance. The allowable thickness will differ from the range described in the above table at other setting distances. Further, double feeds of aluminum foils can also be detected at distances shorter than the above. Please contact our office for details. |
Detectable Sheet Thickness: Applicable Controllers GD-C3: Setting Distance 10 mm 0.394 in | Standard sensing object size: 20 x 20 mm 0.787 x 0.787 in Iron(SPCC): 0.03 to 0.1 mm 0.001 to 0.004 in Aluminum: 0.015 to 1 mm 0.001 to 0.039 in Copper: 0.018 to 0.3 mm 0.001 to 0.012 in Brass: 0.03 to 0.5 mm 0.001 to 0.020 in Stainless steel (SUS304): 0.3 to 1 mm 0.012 to 0.039 in (Note) The above detectable sheet thicknesses are typical data at the given sensing distance. The allowable thickness will differ from the range described in the above table at other setting distances. Further, double feeds of aluminum foils can also be detected at distances shorter than the above. Please contact our office for details. |
Environmental Resistance: Protection | IP67 (IEC) |
Environmental Resistance: Ambient Temperature | -10 to +60 degrees +14 to +140 degrees Fahrenheit , Storage: -25 to +70 degrees -13 to +158 degrees Fahrenheit |
Environmental Resistance: Ambient Humidity | 45 to 85 % RH, Storage: 35 to 95 % RH |
Environmental Resistance: Vibration Resistance | 10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each |
Environmental Resistance: Shock Resistance | 1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions three times each |
Material | Enclosure: Stainless steel (SUS303) Sensing face: ABS |
Cable | Sender: 0.3 2 single core shielded cable, 3 m 9.843 ft long Receiver: 0.1 2 2-core shielded cable, 3 m 9.843 ft long |
Cable Extension | Extension up to total 20 m 65.617 ft is possible with an equivalent shielded cable. |
Weight (Typ.) | Net weight: 90 g approx. |
Accessory | - |