| | Non-threaded type For 0.8 mm 0.031 in sensing | EMC Directive, RoHS Directive | 24 V DC plus or minus 10 % Ripple P-P 10 % or less | 150 mA or less | 0.04 % F.S. (64 times average processing) (Note) This value was obtained at a constant +25 ℃ +77 ℉ . | 40 kHz (25 micro s) | Within plus or minus 0.3 % F.S. (Note) This value was obtained at a constant +25 ℃ +77 ℉ . | 0.07 % F.S./℃ or less (Note) This value represents 20 to 60 % of the maximum sensing distance when combining the sensor head and the controller. | Output voltage: -5 to +5 V (Note1) , Output impedance: 100 Ω approx.(Note2) (Note1: Adjusted to a 0 to +5 V factory setting.) (Note2:When using the BCD output unit GP-XBCD, the analog voltage output of a controller becomes invalid.) | 75 micro s (maximum speed) | NPN open-collector transistor -Maximum sink current: 100 mA -Applied voltage: 30 V DC or less (between comparative output and 0 V) -Residual voltage: 1.6 V or less (at 100 mA sink current), 0.4 V or less (at 16 mA sink current) | DC-12 or DC-13 | HI / GO / LO 3 value output | HI: ON when measured value > the upper limit value GO: ON when upper limit value >= measured value >= lower limit value LO: ON when lower limit value > measured value | Incorporated | Photo-coupler input - Input current: 9 mA or less - Operating voltage: ON voltage 17 V or more (between +24 V and input), OFF voltage 4 V or less (between +24 V and input) - Input impedance: 5 kΩ approx. | RS-232C | Push button setting / External input setting | Orange LED (lights up when in mode status) | Orange LED (lights up when the upper limit value is exceeded) | Green LED (lights up when within the upper and lower limit value) | Orange LED (lights up when less than the lower limit value) | Green LED (lights up as per the external or internal trigger timing) | 5 digit orange LED (display of numerical values out of upper and lower limit value) | 5 digit green LED (display of numerical values within the upper and lower limit value) | 3 (Industrial environment) | -10 to +55 ℃ +14 to +131 ℉ , Storage: -20 to +70 ℃ -4 to +158 ℉ | 35 to 85 % RH, Storage: 35 to 85 % RH | 10 to 150 Hz frequency, 0.75 mm 0.030 in amplitude in X, Y and Z directions for two hours each | 100 m/s2 acceleration (10 G approx.) in X, Y and Z directions five times each | Enclosure: Polycarbonate | Net weight: 120 g approx. | ATA4811 (Controller mounting frame): 1 set | 0 to 0.8 mm 0 to 0.031 in (Note) The sensing range is specified for the standard sensing object. | IP67 (IEC), IP67g (Note:If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil. Please check the resistivity of the sensor against the cutting oil you are using beforehand.) | Stainless steel (SUS304) / Iron sheet [Cold rolled carbon steel (SPCC)] 60 x 60 x t 1 mm 2.362 x 2.362 x t 0.039 in | 250 V AC for one min. between all supply terminals connected together and enclosure | 20 MΩ , or more, with 250 V DC megger between all supply terminals connected together and enclosure | 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions five times each | Stainless steel (SUS303) | - | ABS | High frequency coaxial cable with connector, 3 m 9.843 ft long (Note) For the flexible cable type, please contact our office. | Extension up to total 10 m 32.808 ft is possible with the optional cable. | - | 40 g approx. (Note) The given weight of the threaded type sensor head is the value including the weight of the nuts and the toothed lock washer. |
| | Non-threaded type For 0.8 mm 0.031 in sensing | EMC Directive, RoHS Directive | 24 V DC plus or minus 10 % Ripple P-P 10 % or less | 150 mA or less | 0.04 % F.S. (64 times average processing) (Note) This value was obtained at a constant +25 ℃ +77 ℉ . | 40 kHz (25 micro s) | Within plus or minus 0.3 % F.S. (Note) This value was obtained at a constant +25 ℃ +77 ℉ . | 0.07 % F.S./℃ or less (Note) This value represents 20 to 60 % of the maximum sensing distance when combining the sensor head and the controller. | Output voltage: -5 to +5 V (Note1) , Output impedance: 100 Ω approx.(Note2) (Note1: Adjusted to a 0 to +5 V factory setting.) (Note2:When using the BCD output unit GP-XBCD, the analog voltage output of a controller becomes invalid.) | 75 micro s (maximum speed) | PNP open-collector transistor -Maximum source current: 100 mA -Applied voltage: 30 V DC or less (between comparative output and +V) -Residual voltage: 1.6 V or less (at 100 mA source current), 0.4 V or less (at 16 mA source current) | DC-12 or DC-13 | HI / GO / LO 3 value output | HI: ON when measured value > the upper limit value GO: ON when upper limit value >= measured value >= lower limit value LO: ON when lower limit value > measured value | Incorporated | Photo-coupler input - Input current: 9 mA or less - Operating voltage: ON voltage 17 V or more (between 0 V and input), OFF voltage 4 V or less (between 0 V and input) - Input impedance: 5 kΩ approx. | RS-232C | Push button setting / External input setting | Orange LED (lights up when in mode status) | Orange LED (lights up when the upper limit value is exceeded) | Green LED (lights up when within the upper and lower limit value) | Orange LED (lights up when less than the lower limit value) | Green LED (lights up as per the external or internal trigger timing) | 5 digit orange LED (display of numerical values out of upper and lower limit value) | 5 digit green LED (display of numerical values within the upper and lower limit value) | 3 (Industrial environment) | -10 to +55 ℃ +14 to +131 ℉ , Storage: -20 to +70 ℃ -4 to +158 ℉ | 35 to 85 % RH, Storage: 35 to 85 % RH | 10 to 150 Hz frequency, 0.75 mm 0.030 in amplitude in X, Y and Z directions for two hours each | 100 m/s2 acceleration (10 G approx.) in X, Y and Z directions five times each | Enclosure: Polycarbonate | Net weight: 120 g approx. | ATA4811 (Controller mounting frame): 1 set | 0 to 0.8 mm 0 to 0.031 in (Note) The sensing range is specified for the standard sensing object. | IP67 (IEC), IP67g (Note:If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil. Please check the resistivity of the sensor against the cutting oil you are using beforehand.) | Stainless steel (SUS304) / Iron sheet [Cold rolled carbon steel (SPCC)] 60 x 60 x t 1 mm 2.362 x 2.362 x t 0.039 in | 250 V AC for one min. between all supply terminals connected together and enclosure | 20 MΩ , or more, with 250 V DC megger between all supply terminals connected together and enclosure | 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions five times each | Stainless steel (SUS303) | - | ABS | High frequency coaxial cable with connector, 3 m 9.843 ft long (Note) For the flexible cable type, please contact our office. | Extension up to total 10 m 32.808 ft is possible with the optional cable. | - | 40 g approx. (Note) The given weight of the threaded type sensor head is the value including the weight of the nuts and the toothed lock washer. |
| | Threaded type For 10 mm 0.394 in sensing | EMC Directive, RoHS Directive | 24 V DC plus or minus 10 % Ripple P-P 10 % or less | 150 mA or less | 0.02 % F.S. (64 times average processing) (Note) This value was obtained at a constant +25 ℃ +77 ℉ . | 40 kHz (25 micro s) | Within plus or minus 0.3 % F.S. (Note) This value was obtained at a constant +25 ℃ +77 ℉ . | 0.07 % F.S./℃ or less (Note) This value represents 20 to 60 % of the maximum sensing distance when combining the sensor head and the controller. | Output voltage: -5 to +5 V (Note1) , Output impedance: 100 Ω approx.(Note2) (Note1: Adjusted to a 0 to +5 V factory setting.) (Note2:When using the BCD output unit GP-XBCD, the analog voltage output of a controller becomes invalid.) | 75 micro s (maximum speed) | PNP open-collector transistor -Maximum source current: 100 mA -Applied voltage: 30 V DC or less (between comparative output and +V) -Residual voltage: 1.6 V or less (at 100 mA source current), 0.4 V or less (at 16 mA source current) | DC-12 or DC-13 | HI / GO / LO 3 value output | HI: ON when measured value > the upper limit value GO: ON when upper limit value >= measured value >= lower limit value LO: ON when lower limit value > measured value | Incorporated | Photo-coupler input - Input current: 9 mA or less - Operating voltage: ON voltage 17 V or more (between 0 V and input), OFF voltage 4 V or less (between 0 V and input) - Input impedance: 5 kΩ approx. | RS-232C | Push button setting / External input setting | Orange LED (lights up when in mode status) | Orange LED (lights up when the upper limit value is exceeded) | Green LED (lights up when within the upper and lower limit value) | Orange LED (lights up when less than the lower limit value) | Green LED (lights up as per the external or internal trigger timing) | 5 digit orange LED (display of numerical values out of upper and lower limit value) | 5 digit green LED (display of numerical values within the upper and lower limit value) | 3 (Industrial environment) | -10 to +55 ℃ +14 to +131 ℉ , Storage: -20 to +70 ℃ -4 to +158 ℉ | 35 to 85 % RH, Storage: 35 to 85 % RH | 10 to 150 Hz frequency, 0.75 mm 0.030 in amplitude in X, Y and Z directions for two hours each | 100 m/s2 acceleration (10 G approx.) in X, Y and Z directions five times each | Enclosure: Polycarbonate | Net weight: 120 g approx. | ATA4811 (Controller mounting frame): 1 set | 0 to 10 mm 0 to 0.394 in (Note) The sensing range is specified for the standard sensing object. | IP67 (IEC), IP67g (Note:If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil. Please check the resistivity of the sensor against the cutting oil you are using beforehand.) | Stainless steel (SUS304) / Iron sheet [Cold rolled carbon steel (SPCC)] 60 x 60 x t 1 mm 2.362 x 2.362 x t 0.039 in | 250 V AC for one min. between all supply terminals connected together and enclosure | 20 MΩ , or more, with 250 V DC megger between all supply terminals connected together and enclosure | 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions five times each | Brass (Nickel plated) | PP | PA | High frequency coaxial cable with connector, 3 m 9.843 ft long (Note) For the flexible cable type, please contact our office. | Extension up to total 10 m 32.808 ft is possible with the optional cable. | Nut: 2 pcs. Toothed lock washer: 1 pc. | 80 g approx. (Note) The given weight of the threaded type sensor head is the value including the weight of the nuts and the toothed lock washer. |
| | Threaded type For 10 mm 0.394 in sensing | EMC Directive, RoHS Directive | 24 V DC plus or minus 10 % Ripple P-P 10 % or less | 150 mA or less | 0.02 % F.S. (64 times average processing) (Note) This value was obtained at a constant +25 ℃ +77 ℉ . | 40 kHz (25 micro s) | Within plus or minus 0.3 % F.S. (Note) This value was obtained at a constant +25 ℃ +77 ℉ . | 0.07 % F.S./℃ or less (Note) This value represents 20 to 60 % of the maximum sensing distance when combining the sensor head and the controller. | Output voltage: -5 to +5 V (Note1) , Output impedance: 100 Ω approx.(Note2) (Note1: Adjusted to a 0 to +5 V factory setting.) (Note2:When using the BCD output unit GP-XBCD, the analog voltage output of a controller becomes invalid.) | 75 micro s (maximum speed) | NPN open-collector transistor -Maximum sink current: 100 mA -Applied voltage: 30 V DC or less (between comparative output and 0 V) -Residual voltage: 1.6 V or less (at 100 mA sink current), 0.4 V or less (at 16 mA sink current) | DC-12 or DC-13 | HI / GO / LO 3 value output | HI: ON when measured value > the upper limit value GO: ON when upper limit value >= measured value >= lower limit value LO: ON when lower limit value > measured value | Incorporated | Photo-coupler input - Input current: 9 mA or less - Operating voltage: ON voltage 17 V or more (between +24 V and input), OFF voltage 4 V or less (between +24 V and input) - Input impedance: 5 kΩ approx. | RS-232C | Push button setting / External input setting | Orange LED (lights up when in mode status) | Orange LED (lights up when the upper limit value is exceeded) | Green LED (lights up when within the upper and lower limit value) | Orange LED (lights up when less than the lower limit value) | Green LED (lights up as per the external or internal trigger timing) | 5 digit orange LED (display of numerical values out of upper and lower limit value) | 5 digit green LED (display of numerical values within the upper and lower limit value) | 3 (Industrial environment) | -10 to +55 ℃ +14 to +131 ℉ , Storage: -20 to +70 ℃ -4 to +158 ℉ | 35 to 85 % RH, Storage: 35 to 85 % RH | 10 to 150 Hz frequency, 0.75 mm 0.030 in amplitude in X, Y and Z directions for two hours each | 100 m/s2 acceleration (10 G approx.) in X, Y and Z directions five times each | Enclosure: Polycarbonate | Net weight: 120 g approx. | ATA4811 (Controller mounting frame): 1 set | 0 to 10 mm 0 to 0.394 in (Note) The sensing range is specified for the standard sensing object. | IP67 (IEC), IP67g (Note:If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil. Please check the resistivity of the sensor against the cutting oil you are using beforehand.) | Stainless steel (SUS304) / Iron sheet [Cold rolled carbon steel (SPCC)] 60 x 60 x t 1 mm 2.362 x 2.362 x t 0.039 in | 250 V AC for one min. between all supply terminals connected together and enclosure | 20 MΩ , or more, with 250 V DC megger between all supply terminals connected together and enclosure | 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions five times each | Brass (Nickel plated) | PP | PA | High frequency coaxial cable with connector, 3 m 9.843 ft long (Note) For the flexible cable type, please contact our office. | Extension up to total 10 m 32.808 ft is possible with the optional cable. | Nut: 2 pcs. Toothed lock washer: 1 pc. | 80 g approx. (Note) The given weight of the threaded type sensor head is the value including the weight of the nuts and the toothed lock washer. |
| | Threaded type For 2 mm 0.079 in sensing | EMC Directive, RoHS Directive | | | | | | 0.07 % F.S./℃ or less (Note) This value represents 20 to 60 % of the maximum sensing distance when combining the sensor head and the controller. | | | | | | | | | | | | | | | | | | 3 (Industrial environment) | -10 to +55 ℃ +14 to +131 ℉ , Storage: -20 to +70 ℃ -4 to +158 ℉ | 35 to 85 % RH, Storage: 35 to 85 % RH | 10 to 150 Hz frequency, 0.75 mm 0.030 in amplitude in X, Y and Z directions for two hours each | | | | | 0 to 2 mm 0 to 0.079 in (Note) The sensing range is specified for the standard sensing object. | IP67 (IEC), IP67g (Note:If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil. Please check the resistivity of the sensor against the cutting oil you are using beforehand.) | Stainless steel (SUS304) / Iron sheet [Cold rolled carbon steel (SPCC)] 60 x 60 x t 1 mm 2.362 x 2.362 x t 0.039 in | 250 V AC for one min. between all supply terminals connected together and enclosure | 20 MΩ , or more, with 250 V DC megger between all supply terminals connected together and enclosure | 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions five times each | Stainless steel (SUS303) | PP | ABS | High frequency coaxial cable with connector, 3 m 9.843 ft long (Note) For the flexible cable type, please contact our office. | Extension up to total 10 m 32.808 ft is possible with the optional cable. | Nut: 2 pcs. Toothed lock washer: 1 pc. | 50 g approx. (Note) The given weight of the threaded type sensor head is the value including the weight of the nuts and the toothed lock washer. |
| | Threaded type For 5 mm 0.197 in sensing | EMC Directive, RoHS Directive | | | | | | 0.07 % F.S./℃ or less (Note) This value represents 20 to 60 % of the maximum sensing distance when combining the sensor head and the controller. | | | | | | | | | | | | | | | | | | 3 (Industrial environment) | -10 to +55 ℃ +14 to +131 ℉ , Storage: -20 to +70 ℃ -4 to +158 ℉ | 35 to 85 % RH, Storage: 35 to 85 % RH | 10 to 150 Hz frequency, 0.75 mm 0.030 in amplitude in X, Y and Z directions for two hours each | | | | | 0 to 5 mm 0 to 0.197 in (Note) The sensing range is specified for the standard sensing object. | IP67 (IEC), IP67g (Note:If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil. Please check the resistivity of the sensor against the cutting oil you are using beforehand.) | Stainless steel (SUS304) / Iron sheet [Cold rolled carbon steel (SPCC)] 60 x 60 x t 1 mm 2.362 x 2.362 x t 0.039 in | 250 V AC for one min. between all supply terminals connected together and enclosure | 20 MΩ , or more, with 250 V DC megger between all supply terminals connected together and enclosure | 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions five times each | Brass (Nickel plated) | PP | PA | High frequency coaxial cable with connector, 3 m 9.843 ft long (Note) For the flexible cable type, please contact our office. | Extension up to total 10 m 32.808 ft is possible with the optional cable. | Nut: 2 pcs. Toothed lock washer: 1 pc. | 45 g approx. (Note) The given weight of the threaded type sensor head is the value including the weight of the nuts and the toothed lock washer. |
| | Threaded type For 5 mm 0.197 in sensing | EMC Directive, RoHS Directive | 24 V DC plus or minus 10 % Ripple P-P 10 % or less | 150 mA or less | 0.02 % F.S. (64 times average processing) (Note) This value was obtained at a constant +25 ℃ +77 ℉ . | 40 kHz (25 micro s) | Within plus or minus 0.3 % F.S. (Note) This value was obtained at a constant +25 ℃ +77 ℉ . | 0.07 % F.S./℃ or less (Note) This value represents 20 to 60 % of the maximum sensing distance when combining the sensor head and the controller. | Output voltage: -5 to +5 V (Note1) , Output impedance: 100 Ω approx.(Note2) (Note1: Adjusted to a 0 to +5 V factory setting.) (Note2:When using the BCD output unit GP-XBCD, the analog voltage output of a controller becomes invalid.) | 75 micro s (maximum speed) | PNP open-collector transistor -Maximum source current: 100 mA -Applied voltage: 30 V DC or less (between comparative output and +V) -Residual voltage: 1.6 V or less (at 100 mA source current), 0.4 V or less (at 16 mA source current) | DC-12 or DC-13 | HI / GO / LO 3 value output | HI: ON when measured value > the upper limit value GO: ON when upper limit value >= measured value >= lower limit value LO: ON when lower limit value > measured value | Incorporated | Photo-coupler input - Input current: 9 mA or less - Operating voltage: ON voltage 17 V or more (between 0 V and input), OFF voltage 4 V or less (between 0 V and input) - Input impedance: 5 kΩ approx. | RS-232C | Push button setting / External input setting | Orange LED (lights up when in mode status) | Orange LED (lights up when the upper limit value is exceeded) | Green LED (lights up when within the upper and lower limit value) | Orange LED (lights up when less than the lower limit value) | Green LED (lights up as per the external or internal trigger timing) | 5 digit orange LED (display of numerical values out of upper and lower limit value) | 5 digit green LED (display of numerical values within the upper and lower limit value) | 3 (Industrial environment) | -10 to +55 ℃ +14 to +131 ℉ , Storage: -20 to +70 ℃ -4 to +158 ℉ | 35 to 85 % RH, Storage: 35 to 85 % RH | 10 to 150 Hz frequency, 0.75 mm 0.030 in amplitude in X, Y and Z directions for two hours each | 100 m/s2 acceleration (10 G approx.) in X, Y and Z directions five times each | Enclosure: Polycarbonate | Net weight: 120 g approx. | ATA4811 (Controller mounting frame): 1 set | 0 to 5 mm 0 to 0.197 in (Note) The sensing range is specified for the standard sensing object. | IP67 (IEC), IP67g (Note:If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil. Please check the resistivity of the sensor against the cutting oil you are using beforehand.) | Stainless steel (SUS304) / Iron sheet [Cold rolled carbon steel (SPCC)] 60 x 60 x t 1 mm 2.362 x 2.362 x t 0.039 in | 250 V AC for one min. between all supply terminals connected together and enclosure | 20 MΩ , or more, with 250 V DC megger between all supply terminals connected together and enclosure | 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions five times each | Brass (Nickel plated) | PP | PA | High frequency coaxial cable with connector, 3 m 9.843 ft long (Note) For the flexible cable type, please contact our office. | Extension up to total 10 m 32.808 ft is possible with the optional cable. | Nut: 2 pcs. Toothed lock washer: 1 pc. | 45 g approx. (Note) The given weight of the threaded type sensor head is the value including the weight of the nuts and the toothed lock washer. |
| | Non-threaded type For 1 mm 0.039 in sensing | EMC Directive, RoHS Directive | 24 V DC plus or minus 10 % Ripple P-P 10 % or less | 150 mA or less | 0.04 % F.S. (64 times average processing) (Note) This value was obtained at a constant +25 ℃ +77 ℉ . | 40 kHz (25 micro s) | Within plus or minus 0.3 % F.S. (Note) This value was obtained at a constant +25 ℃ +77 ℉ . | 0.07 % F.S./℃ or less (Note) This value represents 20 to 60 % of the maximum sensing distance when combining the sensor head and the controller. | Output voltage: -5 to +5 V (Note1) , Output impedance: 100 Ω approx.(Note2) (Note1: Adjusted to a 0 to +5 V factory setting.) (Note2:When using the BCD output unit GP-XBCD, the analog voltage output of a controller becomes invalid.) | 75 micro s (maximum speed) | PNP open-collector transistor -Maximum source current: 100 mA -Applied voltage: 30 V DC or less (between comparative output and +V) -Residual voltage: 1.6 V or less (at 100 mA source current), 0.4 V or less (at 16 mA source current) | DC-12 or DC-13 | HI / GO / LO 3 value output | HI: ON when measured value > the upper limit value GO: ON when upper limit value >= measured value >= lower limit value LO: ON when lower limit value > measured value | Incorporated | Photo-coupler input - Input current: 9 mA or less - Operating voltage: ON voltage 17 V or more (between 0 V and input), OFF voltage 4 V or less (between 0 V and input) - Input impedance: 5 kΩ approx. | RS-232C | Push button setting / External input setting | Orange LED (lights up when in mode status) | Orange LED (lights up when the upper limit value is exceeded) | Green LED (lights up when within the upper and lower limit value) | Orange LED (lights up when less than the lower limit value) | Green LED (lights up as per the external or internal trigger timing) | 5 digit orange LED (display of numerical values out of upper and lower limit value) | 5 digit green LED (display of numerical values within the upper and lower limit value) | 3 (Industrial environment) | -10 to +55 ℃ +14 to +131 ℉ , Storage: -20 to +70 ℃ -4 to +158 ℉ | 35 to 85 % RH, Storage: 35 to 85 % RH | 10 to 150 Hz frequency, 0.75 mm 0.030 in amplitude in X, Y and Z directions for two hours each | 100 m/s2 acceleration (10 G approx.) in X, Y and Z directions five times each | Enclosure: Polycarbonate | Net weight: 120 g approx. | ATA4811 (Controller mounting frame): 1 set | 0 to 1 mm 0 to 0.039 in (Note) The sensing range is specified for the standard sensing object. | IP67 (IEC), IP67g (Note:If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil. Please check the resistivity of the sensor against the cutting oil you are using beforehand.) | Stainless steel (SUS304) / Iron sheet [Cold rolled carbon steel (SPCC)] 60 x 60 x t 1 mm 2.362 x 2.362 x t 0.039 in | 250 V AC for one min. between all supply terminals connected together and enclosure | 20 MΩ , or more, with 250 V DC megger between all supply terminals connected together and enclosure | 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions five times each | Stainless steel (SUS303) | PP | PAR | High frequency coaxial cable with connector, 3 m 9.843 ft long (Note) For the flexible cable type, please contact our office. | Extension up to total 10 m 32.808 ft is possible with the optional cable. | - | 40 g approx. (Note) The given weight of the threaded type sensor head is the value including the weight of the nuts and the toothed lock washer. |
| | Non-threaded type For 2 mm 0.079 in sensing | EMC Directive, RoHS Directive | 24 V DC plus or minus 10 % Ripple P-P 10 % or less | 150 mA or less | 0.02 % F.S. (64 times average processing) (Note) This value was obtained at a constant +25 ℃ +77 ℉ . | 40 kHz (25 micro s) | Within plus or minus 0.3 % F.S. (Note) This value was obtained at a constant +25 ℃ +77 ℉ . | 0.07 % F.S./℃ or less (Note) This value represents 20 to 60 % of the maximum sensing distance when combining the sensor head and the controller. | Output voltage: -5 to +5 V (Note1) , Output impedance: 100 Ω approx.(Note2) (Note1: Adjusted to a 0 to +5 V factory setting.) (Note2:When using the BCD output unit GP-XBCD, the analog voltage output of a controller becomes invalid.) | 75 micro s (maximum speed) | PNP open-collector transistor -Maximum source current: 100 mA -Applied voltage: 30 V DC or less (between comparative output and +V) -Residual voltage: 1.6 V or less (at 100 mA source current), 0.4 V or less (at 16 mA source current) | DC-12 or DC-13 | HI / GO / LO 3 value output | HI: ON when measured value > the upper limit value GO: ON when upper limit value >= measured value >= lower limit value LO: ON when lower limit value > measured value | Incorporated | Photo-coupler input - Input current: 9 mA or less - Operating voltage: ON voltage 17 V or more (between 0 V and input), OFF voltage 4 V or less (between 0 V and input) - Input impedance: 5 kΩ approx. | RS-232C | Push button setting / External input setting | Orange LED (lights up when in mode status) | Orange LED (lights up when the upper limit value is exceeded) | Green LED (lights up when within the upper and lower limit value) | Orange LED (lights up when less than the lower limit value) | Green LED (lights up as per the external or internal trigger timing) | 5 digit orange LED (display of numerical values out of upper and lower limit value) | 5 digit green LED (display of numerical values within the upper and lower limit value) | 3 (Industrial environment) | -10 to +55 ℃ +14 to +131 ℉ , Storage: -20 to +70 ℃ -4 to +158 ℉ | 35 to 85 % RH, Storage: 35 to 85 % RH | 10 to 150 Hz frequency, 0.75 mm 0.030 in amplitude in X, Y and Z directions for two hours each | 100 m/s2 acceleration (10 G approx.) in X, Y and Z directions five times each | Enclosure: Polycarbonate | Net weight: 120 g approx. | ATA4811 (Controller mounting frame): 1 set | 0 to 2 mm 0 to 0.079 in (Note) The sensing range is specified for the standard sensing object. | IP67 (IEC), IP67g (Note:If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil. Please check the resistivity of the sensor against the cutting oil you are using beforehand.) | Stainless steel (SUS304) / Iron sheet [Cold rolled carbon steel (SPCC)] 60 x 60 x t 1 mm 2.362 x 2.362 x t 0.039 in | 250 V AC for one min. between all supply terminals connected together and enclosure | 20 MΩ , or more, with 250 V DC megger between all supply terminals connected together and enclosure | 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions five times each | Stainless steel (SUS303) | PP | ABS | High frequency coaxial cable with connector, 3 m 9.843 ft long (Note) For the flexible cable type, please contact our office. | Extension up to total 10 m 32.808 ft is possible with the optional cable. | - | 40 g approx. (Note) The given weight of the threaded type sensor head is the value including the weight of the nuts and the toothed lock washer. |
| | Non-threaded type For 1 mm 0.039 in sensing | EMC Directive, RoHS Directive | | | | | | 0.07 % F.S./℃ or less (Note) This value represents 20 to 60 % of the maximum sensing distance when combining the sensor head and the controller. | | | | | | | | | | | | | | | | | | 3 (Industrial environment) | -10 to +55 ℃ +14 to +131 ℉ , Storage: -20 to +70 ℃ -4 to +158 ℉ | 35 to 85 % RH, Storage: 35 to 85 % RH | 10 to 150 Hz frequency, 0.75 mm 0.030 in amplitude in X, Y and Z directions for two hours each | | | | | 0 to 1 mm 0 to 0.039 in (Note) The sensing range is specified for the standard sensing object. | IP67 (IEC), IP67g (Note:If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil. Please check the resistivity of the sensor against the cutting oil you are using beforehand.) | Stainless steel (SUS304) / Iron sheet [Cold rolled carbon steel (SPCC)] 60 x 60 x t 1 mm 2.362 x 2.362 x t 0.039 in | 250 V AC for one min. between all supply terminals connected together and enclosure | 20 MΩ , or more, with 250 V DC megger between all supply terminals connected together and enclosure | 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions five times each | Stainless steel (SUS303) | PP | PAR | High frequency coaxial cable with connector, 3 m 9.843 ft long (Note) For the flexible cable type, please contact our office. | Extension up to total 10 m 32.808 ft is possible with the optional cable. | - | 40 g approx. (Note) The given weight of the threaded type sensor head is the value including the weight of the nuts and the toothed lock washer. |