| | EMC Directive, RoHS Directive | 6 mm 0.236 in (fixed) | 0.8 × 1.2 mm 0.031 × 0.047 in opaque object | 0.05 mm 0.002 in or less | 0.01 mm 0.0004 in or less | 5 to 24 V DC ±10 % Ripple P-P 10 % or less | 15 mA or less | NPN open-collector transistor ・Maximum sink current: 50 mA ・Applied voltage: 30 V DC or less (between output and 0 V) ・Residual voltage: 2 V or less (at 50 mA sink current), 1 V or less (at 16 mA sink current) | Incorporated with 2 outputs: Light-ON / Dark-ON | Incorporated | Under light received condition: 20 μs or less Under light interrupted condition: 80 μs or less (Maximum response frequency: 3 kHz)(Note) (Note) : The response frequency is the value when the disc, given in the figure below, is rotated.
| Orange LED (lights up under light received condition) | 3 | IP64 (IEC) | -25 to +55 ℃ -13 to +131 ℉ (No dew condensation or icing allowed), Storage: -30 to +80 ℃ -22 to +176 ℉ (Note) : In case is used at an ambient temperature of +50 ℃ +122 ℉, or more, make sure to mount it on a metal body. | 5 to 85 % RH, Storage: 5 to 95 % RH | Fluorescent light: 1,000 ℓx at the light-receiving face | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure | 10 to 2,000 Hz frequency, 1.5 mm 0.059 in double amplitude (maximum acceleration 196 m/s2) in X, Y and Z directions for two hours each | 15,000 m/s2 acceleration (1,500 G approx.) in X, Y and Z directions three times each | Infrared LED (Peak emission wavelength: 855 nm 0.034 mil, non-modulated) | Enclosure: PBT Display section: Polycarbonate | 0.09-mm2 4-core cabtyre cable, PVC, 3 m 9.843 ft long | Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable. (Note 1) : If the cable is extended to 20 m 65.617 ft or longer, confirm that the supply voltage at the end of the cable attached to the sensor is 4.5 V or higher. (Note 2) : For safety applications, do not exceed 30 m 98.425 ft. | Net weight: 30 g approx Gross weight: 35 g approx. | Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 ℃ +73.4 ℉. | UL/c-UL certification |
| | EMC Directive, RoHS Directive | 6 mm 0.236 in (fixed) | 0.8 × 1.2 mm 0.031 × 0.047 in opaque object | 0.05 mm 0.002 in or less | 0.01 mm 0.0004 in or less | 5 to 24 V DC ±10 % Ripple P-P 10 % or less | 15 mA or less | PNP open-collector transistor ・Maximum source current: 50 mA ・Applied voltage: 30 V DC or less (between output and + V) ・Residual voltage: 2 V or less (at 50 mA source current), 1 V or less (at 16 mA source current) | Incorporated with 2 outputs: Light-ON / Dark-ON | Incorporated | Under light received condition: 20 μs or less Under light interrupted condition: 80 μs or less (Maximum response frequency: 3 kHz)(Note) (Note) : The response frequency is the value when the disc, given in the figure below, is rotated.
| Orange LED (lights up under light received condition) | 3 | IP64 (IEC) | -25 to +55 ℃ -13 to +131 ℉ (No dew condensation or icing allowed), Storage: -30 to +80 ℃ -22 to +176 ℉ (Note) : In case is used at an ambient temperature of +50 ℃ +122 ℉, or more, make sure to mount it on a metal body. | 5 to 85 % RH, Storage: 5 to 95 % RH | Fluorescent light: 1,000 ℓx at the light-receiving face | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure | 10 to 2,000 Hz frequency, 1.5 mm 0.059 in double amplitude (maximum acceleration 196 m/s2) in X, Y and Z directions for two hours each | 15,000 m/s2 acceleration (1,500 G approx.) in X, Y and Z directions three times each | Infrared LED (Peak emission wavelength: 855 nm 0.034 mil, non-modulated) | Enclosure: PBT Display section: Polycarbonate | 0.09-mm2 4-core cabtyre cable, PVC, 1 m 3.281 ft long | Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable. (Note 1) : If the cable is extended to 20 m 65.617 ft or longer, confirm that the supply voltage at the end of the cable attached to the sensor is 4.5 V or higher. (Note 2) : For safety applications, do not exceed 30 m 98.425 ft. | Net weight: 10 g approx Gross weight: 15 g approx. | Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 ℃ +73.4 ℉. | UL/c-UL certification |
| | EMC Directive, RoHS Directive | 6 mm 0.236 in (fixed) | 0.8 × 1.2 mm 0.031 × 0.047 in opaque object | 0.05 mm 0.002 in or less | 0.01 mm 0.0004 in or less | 5 to 24 V DC ±10 % Ripple P-P 10 % or less | 15 mA or less | NPN open-collector transistor ・Maximum sink current: 50 mA ・Applied voltage: 30 V DC or less (between output and 0 V) ・Residual voltage: 2 V or less (at 50 mA sink current), 1 V or less (at 16 mA sink current) | Incorporated with 2 outputs: Light-ON / Dark-ON | Incorporated | Under light received condition: 20 μs or less Under light interrupted condition: 80 μs or less (Maximum response frequency: 3 kHz)(Note) (Note) : The response frequency is the value when the disc, given in the figure below, is rotated.
| Orange LED (lights up under light received condition) | 3 | IP64 (IEC) | -25 to +55 ℃ -13 to +131 ℉ (No dew condensation or icing allowed), Storage: -30 to +80 ℃ -22 to +176 ℉ (Note) : In case is used at an ambient temperature of +50 ℃ +122 ℉, or more, make sure to mount it on a metal body. (Note) : Note that the cable loses its flexibility when the ambient temperature decreases to about -10 ℃ +14 ℉. | 5 to 85 % RH, Storage: 5 to 95 % RH | Fluorescent light: 1,000 ℓx at the light-receiving face | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure | 10 to 2,000 Hz frequency, 1.5 mm 0.059 in double amplitude (maximum acceleration 196 m/s2) in X, Y and Z directions for two hours each | 15,000 m/s2 acceleration (1,500 G approx.) in X, Y and Z directions three times each | Infrared LED (Peak emission wavelength: 855 nm 0.034 mil, non-modulated) | Enclosure: PBT Display section: Polycarbonate | 0.1-mm2 4-core bending-resistant cabtyre cable, PVC, 1 m 3.281 ft long (Note) : The cable is a bending-resistant cable usable on a moving base. When the sensor is mounted on a moving base, secure the sensor cable joint at the unit in place so that stress is not applied to it. (Note) : When storing, make sure that the cable does not come into contact with the sensing section or operation indicator. | Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable. (Note 1) : If the cable is extended to 20 m 65.617 ft or longer, confirm that the supply voltage at the end of the cable attached to the sensor is 4.5 V or higher. (Note 2) : For safety applications, do not exceed 30 m 98.425 ft. | Net weight: 10 g approx Gross weight: 15 g approx. | Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 ℃ +73.4 ℉. | UL/c-UL certification |
| | EMC Directive, RoHS Directive | 6 mm 0.236 in (fixed) | 0.8 × 1.2 mm 0.031 × 0.047 in opaque object | 0.05 mm 0.002 in or less | 0.01 mm 0.0004 in or less | 5 to 24 V DC ±10 % Ripple P-P 10 % or less | 15 mA or less | NPN open-collector transistor ・Maximum sink current: 50 mA ・Applied voltage: 30 V DC or less (between output and 0 V) ・Residual voltage: 2 V or less (at 50 mA sink current), 1 V or less (at 16 mA sink current) | Incorporated with 2 outputs: Light-ON / Dark-ON | Incorporated | Under light received condition: 20 μs or less Under light interrupted condition: 80 μs or less (Maximum response frequency: 3 kHz)(Note) (Note) : The response frequency is the value when the disc, given in the figure below, is rotated.
| Orange LED (lights up under light received condition) | 3 | IP64 (IEC) | -25 to +55 ℃ -13 to +131 ℉ (No dew condensation or icing allowed), Storage: -30 to +80 ℃ -22 to +176 ℉ (Note) : In case is used at an ambient temperature of +50 ℃ +122 ℉, or more, make sure to mount it on a metal body. | 5 to 85 % RH, Storage: 5 to 95 % RH | Fluorescent light: 1,000 ℓx at the light-receiving face | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure | 10 to 2,000 Hz frequency, 1.5 mm 0.059 in double amplitude (maximum acceleration 196 m/s2) in X, Y and Z directions for two hours each | 15,000 m/s2 acceleration (1,500 G approx.) in X, Y and Z directions three times each | Infrared LED (Peak emission wavelength: 855 nm 0.034 mil, non-modulated) | Enclosure: PBT Display section: Polycarbonate | 0.09-mm2 4-core cabtyre cable, PVC, 3 m 9.843 ft long | Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable. (Note 1) : If the cable is extended to 20 m 65.617 ft or longer, confirm that the supply voltage at the end of the cable attached to the sensor is 4.5 V or higher. (Note 2) : For safety applications, do not exceed 30 m 98.425 ft. | Net weight: 30 g approx Gross weight: 35 g approx. | Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 ℃ +73.4 ℉. | UL/c-UL certification |
| | EMC Directive, RoHS Directive | 6 mm 0.236 in (fixed) | 0.8 × 1.2 mm 0.031 × 0.047 in opaque object | 0.05 mm 0.002 in or less | 0.01 mm 0.0004 in or less | 5 to 24 V DC ±10 % Ripple P-P 10 % or less | 15 mA or less | NPN open-collector transistor ・Maximum sink current: 50 mA ・Applied voltage: 30 V DC or less (between output and 0 V) ・Residual voltage: 2 V or less (at 50 mA sink current), 1 V or less (at 16 mA sink current) | Incorporated with 2 outputs: Light-ON / Dark-ON | Incorporated | Under light received condition: 20 μs or less Under light interrupted condition: 80 μs or less (Maximum response frequency: 3 kHz)(Note) (Note) : The response frequency is the value when the disc, given in the figure below, is rotated.
| Orange LED (lights up under light received condition) | 3 | IP64 (IEC) | -25 to +55 ℃ -13 to +131 ℉ (No dew condensation or icing allowed), Storage: -30 to +80 ℃ -22 to +176 ℉ (Note) : In case is used at an ambient temperature of +50 ℃ +122 ℉, or more, make sure to mount it on a metal body. | 5 to 85 % RH, Storage: 5 to 95 % RH | Fluorescent light: 1,000 ℓx at the light-receiving face | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure | 10 to 2,000 Hz frequency, 1.5 mm 0.059 in double amplitude (maximum acceleration 196 m/s2) in X, Y and Z directions for two hours each | 15,000 m/s2 acceleration (1,500 G approx.) in X, Y and Z directions three times each | Infrared LED (Peak emission wavelength: 855 nm 0.034 mil, non-modulated) | Enclosure: PBT Display section: Polycarbonate | 0.09-mm2 4-core cabtyre cable, PVC, 1 m 3.281 ft long | Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable. (Note 1) : If the cable is extended to 20 m 65.617 ft or longer, confirm that the supply voltage at the end of the cable attached to the sensor is 4.5 V or higher. (Note 2) : For safety applications, do not exceed 30 m 98.425 ft. | Net weight: 10 g approx Gross weight: 15 g approx. | Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 ℃ +73.4 ℉. | UL/c-UL certification, Korea’s S-mark certification |
| | EMC Directive, RoHS Directive | 6 mm 0.236 in (fixed) | 0.8 × 1.2 mm 0.031 × 0.047 in opaque object | 0.05 mm 0.002 in or less | 0.01 mm 0.0004 in or less | 5 to 24 V DC ±10 % Ripple P-P 10 % or less | 15 mA or less | NPN open-collector transistor ・Maximum sink current: 50 mA ・Applied voltage: 30 V DC or less (between output and 0 V) ・Residual voltage: 2 V or less (at 50 mA sink current), 1 V or less (at 16 mA sink current) | Incorporated with 2 outputs: Light-ON / Dark-ON | Incorporated | Under light received condition: 20 μs or less Under light interrupted condition: 80 μs or less (Maximum response frequency: 3 kHz)(Note) (Note) : The response frequency is the value when the disc, given in the figure below, is rotated.
| Orange LED (lights up under light received condition) | 3 | IP64 (IEC) | -25 to +55 ℃ -13 to +131 ℉ (No dew condensation or icing allowed), Storage: -30 to +80 ℃ -22 to +176 ℉ (Note) : In case is used at an ambient temperature of +50 ℃ +122 ℉, or more, make sure to mount it on a metal body. | 5 to 85 % RH, Storage: 5 to 95 % RH | Fluorescent light: 1,000 ℓx at the light-receiving face | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure | 10 to 2,000 Hz frequency, 1.5 mm 0.059 in double amplitude (maximum acceleration 196 m/s2) in X, Y and Z directions for two hours each | 15,000 m/s2 acceleration (1,500 G approx.) in X, Y and Z directions three times each | Infrared LED (Peak emission wavelength: 855 nm 0.034 mil, non-modulated) | Enclosure: PBT Display section: Polycarbonate | 0.09-mm2 4-core cabtyre cable, PVC, 3 m 9.843 ft long | Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable. (Note 1) : If the cable is extended to 20 m 65.617 ft or longer, confirm that the supply voltage at the end of the cable attached to the sensor is 4.5 V or higher. (Note 2) : For safety applications, do not exceed 30 m 98.425 ft. | Net weight: 30 g approx Gross weight: 35 g approx. | Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 ℃ +73.4 ℉. | UL/c-UL certification |
| | EMC Directive, RoHS Directive | 6 mm 0.236 in (fixed) | 0.8 × 1.2 mm 0.031 × 0.047 in opaque object | 0.05 mm 0.002 in or less | 0.01 mm 0.0004 in or less | 5 to 24 V DC ±10 % Ripple P-P 10 % or less | 15 mA or less | NPN open-collector transistor ・Maximum sink current: 50 mA ・Applied voltage: 30 V DC or less (between output and 0 V) ・Residual voltage: 2 V or less (at 50 mA sink current), 1 V or less (at 16 mA sink current) | Incorporated with 2 outputs: Light-ON / Dark-ON | Incorporated | Under light received condition: 20 μs or less Under light interrupted condition: 80 μs or less (Maximum response frequency: 3 kHz)(Note) (Note) : The response frequency is the value when the disc, given in the figure below, is rotated.
| Orange LED (lights up under light received condition) | 3 | IP64 (IEC) | -25 to +55 ℃ -13 to +131 ℉ (No dew condensation or icing allowed), Storage: -30 to +80 ℃ -22 to +176 ℉ (Note) : In case is used at an ambient temperature of +50 ℃ +122 ℉, or more, make sure to mount it on a metal body. (Note) : Note that the cable loses its flexibility when the ambient temperature decreases to about -10 ℃ +14 ℉. | 5 to 85 % RH, Storage: 5 to 95 % RH | Fluorescent light: 1,000 ℓx at the light-receiving face | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure | 10 to 2,000 Hz frequency, 1.5 mm 0.059 in double amplitude (maximum acceleration 196 m/s2) in X, Y and Z directions for two hours each | 15,000 m/s2 acceleration (1,500 G approx.) in X, Y and Z directions three times each | Infrared LED (Peak emission wavelength: 855 nm 0.034 mil, non-modulated) | Enclosure: PBT Display section: Polycarbonate | 0.1-mm2 4-core bending-resistant cabtyre cable, PVC, 1 m 3.281 ft long (Note) : The cable is a bending-resistant cable usable on a moving base. When the sensor is mounted on a moving base, secure the sensor cable joint at the unit in place so that stress is not applied to it. (Note) : When storing, make sure that the cable does not come into contact with the sensing section or operation indicator. | Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable. (Note 1) : If the cable is extended to 20 m 65.617 ft or longer, confirm that the supply voltage at the end of the cable attached to the sensor is 4.5 V or higher. (Note 2) : For safety applications, do not exceed 30 m 98.425 ft. | Net weight: 10 g approx Gross weight: 15 g approx. | Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 ℃ +73.4 ℉. | UL/c-UL certification |
| | EMC Directive, RoHS Directive | 6 mm 0.236 in (fixed) | 0.8 × 1.2 mm 0.031 × 0.047 in opaque object | 0.05 mm 0.002 in or less | 0.01 mm 0.0004 in or less | 5 to 24 V DC ±10 % Ripple P-P 10 % or less | 15 mA or less | NPN open-collector transistor ・Maximum sink current: 50 mA ・Applied voltage: 30 V DC or less (between output and 0 V) ・Residual voltage: 2 V or less (at 50 mA sink current), 1 V or less (at 16 mA sink current) | Incorporated with 2 outputs: Light-ON / Dark-ON | Incorporated | Under light received condition: 20 μs or less Under light interrupted condition: 80 μs or less (Maximum response frequency: 3 kHz)(Note) (Note) : The response frequency is the value when the disc, given in the figure below, is rotated.
| Orange LED (lights up under light received condition) | 3 | IP64 (IEC) | -25 to +55 ℃ -13 to +131 ℉ (No dew condensation or icing allowed), Storage: -30 to +80 ℃ -22 to +176 ℉ (Note) : In case is used at an ambient temperature of +50 ℃ +122 ℉, or more, make sure to mount it on a metal body. | 5 to 85 % RH, Storage: 5 to 95 % RH | Fluorescent light: 1,000 ℓx at the light-receiving face | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure | 10 to 2,000 Hz frequency, 1.5 mm 0.059 in double amplitude (maximum acceleration 196 m/s2) in X, Y and Z directions for two hours each | 15,000 m/s2 acceleration (1,500 G approx.) in X, Y and Z directions three times each | Infrared LED (Peak emission wavelength: 855 nm 0.034 mil, non-modulated) | Enclosure: PBT Display section: Polycarbonate | 0.09-mm2 4-core cabtyre cable, PVC, 3 m 9.843 ft long | Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable. (Note 1) : If the cable is extended to 20 m 65.617 ft or longer, confirm that the supply voltage at the end of the cable attached to the sensor is 4.5 V or higher. (Note 2) : For safety applications, do not exceed 30 m 98.425 ft. | Net weight: 30 g approx Gross weight: 35 g approx. | Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 ℃ +73.4 ℉. | UL/c-UL certification |
| | EMC Directive, RoHS Directive | 6 mm 0.236 in (fixed) | 0.8 × 1.2 mm 0.031 × 0.047 in opaque object | 0.05 mm 0.002 in or less | 0.01 mm 0.0004 in or less | 5 to 24 V DC ±10 % Ripple P-P 10 % or less | 15 mA or less | NPN open-collector transistor ・Maximum sink current: 50 mA ・Applied voltage: 30 V DC or less (between output and 0 V) ・Residual voltage: 2 V or less (at 50 mA sink current), 1 V or less (at 16 mA sink current) | Incorporated with 2 outputs: Light-ON / Dark-ON | Incorporated | Under light received condition: 20 μs or less Under light interrupted condition: 80 μs or less (Maximum response frequency: 3 kHz)(Note) (Note) : The response frequency is the value when the disc, given in the figure below, is rotated.
| Orange LED (lights up under light received condition) | 3 | IP64 (IEC) | -25 to +55 ℃ -13 to +131 ℉ (No dew condensation or icing allowed), Storage: -30 to +80 ℃ -22 to +176 ℉ (Note) : In case is used at an ambient temperature of +50 ℃ +122 ℉, or more, make sure to mount it on a metal body. (Note) : Note that the cable loses its flexibility when the ambient temperature decreases to about -10 ℃ +14 ℉. | 5 to 85 % RH, Storage: 5 to 95 % RH | Fluorescent light: 1,000 ℓx at the light-receiving face | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure | 10 to 2,000 Hz frequency, 1.5 mm 0.059 in double amplitude (maximum acceleration 196 m/s2) in X, Y and Z directions for two hours each | 15,000 m/s2 acceleration (1,500 G approx.) in X, Y and Z directions three times each | Infrared LED (Peak emission wavelength: 855 nm 0.034 mil, non-modulated) | Enclosure: PBT Display section: Polycarbonate | 0.1-mm2 4-core bending-resistant cabtyre cable, PVC, 1 m 3.281 ft long (Note) : The cable is a bending-resistant cable usable on a moving base. When the sensor is mounted on a moving base, secure the sensor cable joint at the unit in place so that stress is not applied to it. (Note) : When storing, make sure that the cable does not come into contact with the sensing section or operation indicator. | Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable. (Note 1) : If the cable is extended to 20 m 65.617 ft or longer, confirm that the supply voltage at the end of the cable attached to the sensor is 4.5 V or higher. (Note 2) : For safety applications, do not exceed 30 m 98.425 ft. | Net weight: 10 g approx Gross weight: 15 g approx. | Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 ℃ +73.4 ℉. | UL/c-UL certification |
| | EMC Directive, RoHS Directive | 6 mm 0.236 in (fixed) | 0.8 × 1.2 mm 0.031 × 0.047 in opaque object | 0.05 mm 0.002 in or less | 0.01 mm 0.0004 in or less | 5 to 24 V DC ±10 % Ripple P-P 10 % or less | 15 mA or less | NPN open-collector transistor ・Maximum sink current: 50 mA ・Applied voltage: 30 V DC or less (between output and 0 V) ・Residual voltage: 2 V or less (at 50 mA sink current), 1 V or less (at 16 mA sink current) | Incorporated with 2 outputs: Light-ON / Dark-ON | Incorporated | Under light received condition: 20 μs or less Under light interrupted condition: 80 μs or less (Maximum response frequency: 3 kHz)(Note) (Note) : The response frequency is the value when the disc, given in the figure below, is rotated.
| Orange LED (lights up under light received condition) | 3 | IP64 (IEC) | -25 to +55 ℃ -13 to +131 ℉ (No dew condensation or icing allowed), Storage: -30 to +80 ℃ -22 to +176 ℉ (Note) : In case is used at an ambient temperature of +50 ℃ +122 ℉, or more, make sure to mount it on a metal body. (Note) : Note that the cable loses its flexibility when the ambient temperature decreases to about -10 ℃ +14 ℉. | 5 to 85 % RH, Storage: 5 to 95 % RH | Fluorescent light: 1,000 ℓx at the light-receiving face | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure | 10 to 2,000 Hz frequency, 1.5 mm 0.059 in double amplitude (maximum acceleration 196 m/s2) in X, Y and Z directions for two hours each | 15,000 m/s2 acceleration (1,500 G approx.) in X, Y and Z directions three times each | Infrared LED (Peak emission wavelength: 855 nm 0.034 mil, non-modulated) | Enclosure: PBT Display section: Polycarbonate | 0.1-mm2 4-core bending-resistant cabtyre cable, PVC, 1 m 3.281 ft long (Note) : The cable is a bending-resistant cable usable on a moving base. When the sensor is mounted on a moving base, secure the sensor cable joint at the unit in place so that stress is not applied to it. (Note) : When storing, make sure that the cable does not come into contact with the sensing section or operation indicator. | Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable. (Note 1) : If the cable is extended to 20 m 65.617 ft or longer, confirm that the supply voltage at the end of the cable attached to the sensor is 4.5 V or higher. (Note 2) : For safety applications, do not exceed 30 m 98.425 ft. | Net weight: 10 g approx Gross weight: 15 g approx. | Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 ℃ +73.4 ℉. | UL/c-UL certification |