| | EMC Directive, RoHS Directive | 5 mm 0.197 in ± 10 % (Note)The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation. | 0 to 4 mm 0 to 0.157 in (Note)The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation. | Iron sheet 25 × 25 × t 1 mm 0.984 × 0.984 × t 0.039 in | 15 % or less of operation distance (with standard sensing object) | 10 to 30 V DC Ripple P-P 10 % or less | 10 mA or less | NPN open-collector transistor - Maximum sink current: 100 mA - Applied voltage: 30 V DC or less (between output and 0 V) - Residual voltage: 1.5 V or less (at 100 mA sink current), 0.4 V or less (at 16 mA sink current) | DC-12 or DC-13 | Normally open | 1kHz | Red LED (lights up when the output is ON) | 3 (Industrial environment) | IP67 (IEC), IP67g (JEM) (Note:If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil.
Please check the resistivity of the sensor against the cutting oil you are using beforehand.) | -25 to +70 ℃ -13 to +158℉, Storage: -25 to +70 ℃ -13 to +158℉ | 45 to 85 % RH, Storage: 45 to 85 % RH | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 50 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure | 10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each | 1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions three times each | Over ambient temperature range -25 to +70 ℃ -13 to +158℉ : within ±10 % of sensing range at +20 ℃ +68℉ | Within ±2 % for ±10 % fluctuation of the supply voltage | Enclosure: Polyarylate | 0.3 mm2 3-core oil resistant cabtyre cable, 1 m 3.281 ft long | Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable. | Net weight : 45 g approx. | - |
| | EMC Directive, RoHS Directive | 12 mm 0.472 in ± 10 % (Note)The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation. | 0 to 10 mm 0 to 0.394 in (Note)The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation. | Iron sheet 40 × 40 × t 1 mm 1.575 × 1.575 × t 0.039 in | 15 % or less of operation distance (with standard sensing object) | 10 to 30 V DC Ripple P-P 10 % or less | 10 mA or less | NPN open-collector transistor - Maximum sink current: 100 mA - Applied voltage: 30 V DC or less (between output and 0 V) - Residual voltage: 1.5 V or less (at 100 mA sink current), 0.4 V or less (at 16 mA sink current) | DC-12 or DC-13 | Normally closed | 500Hz | Red LED (lights up when the output is ON) | 3 (Industrial environment) | IP67 (IEC), IP67g (JEM) (Note:If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil.
Please check the resistivity of the sensor against the cutting oil you are using beforehand.) | -25 to +70 ℃ -13 to +158℉, Storage: -25 to +70 ℃ -13 to +158℉ | 45 to 85 % RH, Storage: 45 to 85 % RH | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 50 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure | 10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each | 1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions three times each | Over ambient temperature range -25 to +70 ℃ -13 to +158℉ : within ±10 % of sensing range at +20 ℃ +68℉ | Within ±2 % for ±10 % fluctuation of the supply voltage | Enclosure: Polyarylate | 0.3 mm2 3-core oil resistant cabtyre cable, 1 m 3.281 ft long | Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable. | Net weight : 45 g approx. | MS-GL18HL (Sensor mounting bracket): 1 set |
| | EMC Directive, RoHS Directive | 5 mm 0.197 in ± 10 % (Note)The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation. | 0 to 4 mm 0 to 0.157 in (Note)The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation. | Iron sheet 25 × 25 × t 1 mm 0.984 × 0.984 × t 0.039 in | 15 % or less of operation distance (with standard sensing object) | 10 to 30 V DC Ripple P-P 10 % or less | 10 mA or less | NPN open-collector transistor - Maximum sink current: 100 mA - Applied voltage: 30 V DC or less (between output and 0 V) - Residual voltage: 1.5 V or less (at 100 mA sink current), 0.4 V or less (at 16 mA sink current) | DC-12 or DC-13 | Normally closed | 1kHz | Red LED (lights up when the output is ON) | 3 (Industrial environment) | IP67 (IEC), IP67g (JEM) (Note:If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil.
Please check the resistivity of the sensor against the cutting oil you are using beforehand.) | -25 to +70 ℃ -13 to +158℉, Storage: -25 to +70 ℃ -13 to +158℉ | 45 to 85 % RH, Storage: 45 to 85 % RH | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 50 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure | 10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each | 1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions three times each | Over ambient temperature range -25 to +70 ℃ -13 to +158℉ : within ±10 % of sensing range at +20 ℃ +68℉ | Within ±2 % for ±10 % fluctuation of the supply voltage | Enclosure: Polyarylate | 0.3 mm2 3-core oil resistant cabtyre cable, 1 m 3.281 ft long | Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable. | Net weight : 45 g approx. | - |
| | EMC Directive, RoHS Directive | 5 mm 0.197 in ± 10 % (Note)The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation. | 0 to 4 mm 0 to 0.157 in (Note)The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation. | Iron sheet 25 × 25 × t 1 mm 0.984 × 0.984 × t 0.039 in | 15 % or less of operation distance (with standard sensing object) | 10 to 30 V DC Ripple P-P 10 % or less | 10 mA or less | NPN open-collector transistor - Maximum sink current: 100 mA - Applied voltage: 30 V DC or less (between output and 0 V) - Residual voltage: 1.5 V or less (at 100 mA sink current), 0.4 V or less (at 16 mA sink current) | DC-12 or DC-13 | Normally open | 1kHz | Red LED (lights up when the output is ON) | 3 (Industrial environment) | IP67 (IEC), IP67g (JEM) (Note:If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil.
Please check the resistivity of the sensor against the cutting oil you are using beforehand.) | -25 to +70 ℃ -13 to +158℉, Storage: -25 to +70 ℃ -13 to +158℉ | 45 to 85 % RH, Storage: 45 to 85 % RH | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 50 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure | 10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each | 1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions three times each | Over ambient temperature range -25 to +70 ℃ -13 to +158℉ : within ±10 % of sensing range at +20 ℃ +68℉ | Within ±2 % for ±10 % fluctuation of the supply voltage | Enclosure: Polyarylate | 0.3 mm2 3-core oil resistant cabtyre cable, 1 m 3.281 ft long | Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable. | Net weight : 45 g approx. | - |
| | EMC Directive, RoHS Directive | 12 mm 0.472 in ± 10 % (Note)The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation. | 0 to 10 mm 0 to 0.394 in (Note)The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation. | Iron sheet 40 × 40 × t 1 mm 1.575 × 1.575 × t 0.039 in | 15 % or less of operation distance (with standard sensing object) | 10 to 30 V DC Ripple P-P 10 % or less | 10 mA or less | NPN open-collector transistor - Maximum sink current: 100 mA - Applied voltage: 30 V DC or less (between output and 0 V) - Residual voltage: 1.5 V or less (at 100 mA sink current), 0.4 V or less (at 16 mA sink current) | DC-12 or DC-13 | Normally open | 500Hz | Red LED (lights up when the output is ON) | 3 (Industrial environment) | IP67 (IEC), IP67g (JEM) (Note:If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil.
Please check the resistivity of the sensor against the cutting oil you are using beforehand.) | -25 to +70 ℃ -13 to +158℉, Storage: -25 to +70 ℃ -13 to +158℉ | 45 to 85 % RH, Storage: 45 to 85 % RH | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 50 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure | 10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each | 1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions three times each | Over ambient temperature range -25 to +70 ℃ -13 to +158℉ : within ±10 % of sensing range at +20 ℃ +68℉ | Within ±2 % for ±10 % fluctuation of the supply voltage | Enclosure: Polyarylate | 0.3 mm2 3-core oil resistant cabtyre cable, 1 m 3.281 ft long | Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable. | Net weight : 45 g approx. | MS-GL18HL (Sensor mounting bracket): 1 set |
| | EMC Directive, RoHS Directive | 12 mm 0.472 in ± 10 % (Note)The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation. | 0 to 10 mm 0 to 0.394 in (Note)The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation. | Iron sheet 40 × 40 × t 1 mm 1.575 × 1.575 × t 0.039 in | 15 % or less of operation distance (with standard sensing object) | 10 to 30 V DC Ripple P-P 10 % or less | 10 mA or less | NPN open-collector transistor - Maximum sink current: 100 mA - Applied voltage: 30 V DC or less (between output and 0 V) - Residual voltage: 1.5 V or less (at 100 mA sink current), 0.4 V or less (at 16 mA sink current) | DC-12 or DC-13 | Normally open | 500Hz | Red LED (lights up when the output is ON) | 3 (Industrial environment) | IP67 (IEC), IP67g (JEM) (Note:If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil.
Please check the resistivity of the sensor against the cutting oil you are using beforehand.) | -25 to +70 ℃ -13 to +158℉, Storage: -25 to +70 ℃ -13 to +158℉ | 45 to 85 % RH, Storage: 45 to 85 % RH | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 50 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure | 10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each | 1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions three times each | Over ambient temperature range -25 to +70 ℃ -13 to +158℉ : within ±10 % of sensing range at +20 ℃ +68℉ | Within ±2 % for ±10 % fluctuation of the supply voltage | Enclosure: Polyarylate | 0.3 mm2 3-core oil resistant cabtyre cable, 1 m 3.281 ft long | Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable. | Net weight : 45 g approx. | MS-GL18HL (Sensor mounting bracket): 1 set |