| | EMC Directive, RoHS Directive | 10 m 32.808 ft | 13 m 32.808 ft | 16 m 32.808 ft | 19 m 32.808 ft | 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less | Emitter: 20 mA or less Receiver: 25 mA or less | NPN open-collector transistor - Maximum sink current: 100 mA - Applied voltage: 30 V DC or less (between sensing output and 0 V) - Residual voltage: 2 V or less (at 100 mA sink current), 1 V or less (at 16 mA sink current) | DC-12 or DC-13 | Switchable either Light-ON or Dark-ON | Incorporated | NPN open-collector transistor - Maximum sink current: 50 mA - Applied voltage: 30 V DC or less (between self-diagnosis output and 0 V) - Residual voltage: 1.5 V or less (at 50 mA sink current), 1 V or less (at 16 mA sink current) | ON under unstable sensing condition | - | 1 ms or less | Incorporated | Green LED (lights up under stable light received condition or stable dark condition) | Red LED (lights up when the sensing output is ON) | Red LED (lights up during beam emission) | - | Continuously variable adjuster | IP67 (IEC) | -25 to +60 degrees -13 to +140 degrees Fahrenheit (No dew condensation or icing allowed), Storage: -30 to +70 degrees -22 to +158 degrees Fahrenheit | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 3,500 Lx or less at the light-receiving face | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure | 10 to 500 Hz frequency, 1.5 mm 0.059 in double amplitude (10 G max.) in X, Y and Z directions for two hours each | 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each | Infrared LED | 880 nm 0.035 mil | Enclosure: Die-cast zinc alloy Indicator cover: Polyethersulphone Lens: Polycarbonate | Emitter: 0.15 mm2 3-core oil, heat and cold resistant cabtyre cable, 5 m 16.404 ft long Receiver: 0.15 mm2 4-core oil, heat and cold resistant cabtyre cable, 5 m 16.404 ft long | Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable (both emitter and receiver). | | MS-RX-1 (Sensor mounting bracket): 1 set for emitter and receiver Adjusting screwdriver: 1 pc | 22 m 32.808 ft | | |
| | EMC Directive, RoHS Directive | 2 m 6.562 ft | dia. 10 mm dia. 0.394 in or more opaque object | - | 0.5 mm 0.020 in or less | 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less | Emitter: 20 mA or less Receiver: 25 mA or less | NPN open-collector transistor - Maximum sink current: 100 mA - Applied voltage: 30 V DC or less (between sensing output and 0 V) - Residual voltage: 2 V or less (at 100 mA sink current), 1 V or less (at 16 mA sink current) | DC-12 or DC-13 | Switchable either Light-ON or Dark-ON | Incorporated | NPN open-collector transistor - Maximum sink current: 50 mA - Applied voltage: 30 V DC or less (between self-diagnosis output and 0 V) - Residual voltage: 1.5 V or less (at 50 mA sink current), 1 V or less (at 16 mA sink current) | ON under unstable sensing condition | - | 1 ms or less | Incorporated | Green LED (lights up under stable light received condition or stable dark condition) | Red LED (lights up when the sensing output is ON) | Red LED (lights up during beam emission) | - | Continuously variable adjuster | IP67 (IEC) | -25 to +60 degrees -13 to +140 degrees Fahrenheit (No dew condensation or icing allowed), Storage: -30 to +70 degrees -22 to +158 degrees Fahrenheit | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 3,500 Lx or less at the light-receiving face | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure | 10 to 500 Hz frequency, 1.5 mm 0.059 in double amplitude (10 G max.) in X, Y and Z directions for two hours each | 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each | Red LED | 680 nm 0.027 mil | Enclosure: Die-cast zinc alloy Indicator cover: Polyethersulphone Lens: Polycarbonate | Emitter: 0.15 mm2 3-core oil, heat and cold resistant cabtyre cable, 5 m 16.404 ft long Receiver: 0.15 mm2 4-core oil, heat and cold resistant cabtyre cable, 5 m 16.404 ft long | Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable (both emitter and receiver). | | MS-RX-1 (Sensor mounting bracket): 1 set for emitter and receiver Adjusting screwdriver: 1 pc | | | |
| | EMC Directive, RoHS Directive | 5 m 16.404 ft | dia. 10 mm dia. 0.394 in or more opaque object | | | 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less | Emitter: 20 mA or less Receiver: 25 mA or less | NPN open-collector transistor - Maximum sink current: 100 mA - Applied voltage: 30 V DC or less (between sensing output and 0 V) - Residual voltage: 2 V or less (at 100 mA sink current), 1 V or less (at 16 mA sink current) | | Switchable either Light-ON or Dark-ON | Incorporated | NPN open-collector transistor - Maximum sink current: 50 mA - Applied voltage: 30 V DC or less (between self-diagnosis output and 0 V) - Residual voltage: 1.5 V or less (at 50 mA sink current), 1 V or less (at 16 mA sink current) | ON under unstable sensing condition | - | 1 ms or less | Incorporated | Green LED (lights up under stable light received condition or stable dark condition) | Red LED (lights up when the sensing output is ON) | Red LED (lights up during beam emission) | | Continuously variable adjuster | IP67 (IEC), IP67g (JEM) | -25 to +60 degrees -13 to +140 degrees Fahrenheit (No dew condensation or icing allowed), Storage: -30 to +70 degrees -22 to +158 degrees Fahrenheit | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 3,500 Lx or less at the light-receiving face | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure | 10 to 500 Hz frequency, 1.5 mm 0.059 in double amplitude (10 G max.) in X, Y and Z directions for two hours each | 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each | | | Enclosure: Die-cast zinc alloy (Fluorine resin coating) Indicator cover: Polyethersulphone Lens: Polyalylate, Protective tube sheath: Oil resistant PVC | 0.15 mm2 4-core (emitter: 3-core) oil, heat and cold resistant cabtyre cable | Extension up to total 100 m 328.084 ft is possible for both emitter and receiver with 0.3 mm2, or more, cable. | Emitter: 175 g approx Receiver: 175 g approx | MS-RX-2 (Sensor mounting bracket): 1 set for emitter and receiver Adjusting screwdriver: 1 pc | 0.5 mm 0.020 in or less | Infrared LED (Peak emission wavelength: 880 nm 0.035 mil, modulated) | 1 m 3.281 ft |
| | EMC Directive, RoHS Directive | 5 m 16.404 ft | dia. 10 mm dia. 0.394 in or more opaque object | | | 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less | Emitter: 20 mA or less Receiver: 25 mA or less | NPN open-collector transistor - Maximum sink current: 100 mA - Applied voltage: 30 V DC or less (between sensing output and 0 V) - Residual voltage: 2 V or less (at 100 mA sink current), 1 V or less (at 16 mA sink current) | | Switchable either Light-ON or Dark-ON | Incorporated | NPN open-collector transistor - Maximum sink current: 50 mA - Applied voltage: 30 V DC or less (between self-diagnosis output and 0 V) - Residual voltage: 1.5 V or less (at 50 mA sink current), 1 V or less (at 16 mA sink current) | ON under unstable sensing condition | - | 1 ms or less | Incorporated | Green LED (lights up under stable light received condition or stable dark condition) | Red LED (lights up when the sensing output is ON) | Red LED (lights up during beam emission) | | Continuously variable adjuster | IP67 (IEC), IP67g (JEM) | -25 to +60 degrees -13 to +140 degrees Fahrenheit (No dew condensation or icing allowed), Storage: -30 to +70 degrees -22 to +158 degrees Fahrenheit | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 3,500 Lx or less at the light-receiving face | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure | 10 to 500 Hz frequency, 1.5 mm 0.059 in double amplitude (10 G max.) in X, Y and Z directions for two hours each | 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each | | | Enclosure: Die-cast zinc alloy (Fluorine resin coating) Indicator cover: Polyethersulphone Lens: Polyalylate, Protective tube sheath: Oil resistant PVC | 0.15 mm2 4-core (emitter: 3-core) oil, heat and cold resistant cabtyre cable | Extension up to total 100 m 328.084 ft is possible for both emitter and receiver with 0.3 mm2, or more, cable. | Emitter: 265 g approx Receiver: 265 g approx | MS-RX-2 (Sensor mounting bracket): 1 set for emitter and receiver Adjusting screwdriver: 1 pc | 0.5 mm 0.020 in or less | Infrared LED (Peak emission wavelength: 880 nm 0.035 mil, modulated) | 2 m 6.562 ft |
| | EMC Directive, RoHS Directive | 0.1 to 3 m 0.328 to 9.843 ft (Note) The sensing range and the sensing object for the retroreflective type sensor are specified for the RF-230 reflector. Further, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m 0.328 ft away. | dia. 50 mm dia. 1.969 in or more opaque, translucent or specular object (Note) The sensing range and the sensing object for the retroreflective type sensor are specified for the RF-230 reflector. Further, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m 0.328 ft away. (Note) Make sure to confirm detection with an actual sensor before use. | - | 1 mm 0.039 in or less | 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less | 40 mA or less | NPN open-collector transistor - Maximum sink current: 100 mA - Applied voltage: 30 V DC or less (between sensing output and 0 V) - Residual voltage: 2 V or less (at 100 mA sink current), 1 V or less (at 16 mA sink current) | DC-12 or DC-13 | Switchable either Light-ON or Dark-ON | Incorporated | NPN open-collector transistor - Maximum sink current: 50 mA - Applied voltage: 30 V DC or less (between self-diagnosis output and 0 V) - Residual voltage: 1.5 V or less (at 50 mA sink current), 1 V or less (at 16 mA sink current) | ON under unstable sensing condition | - | 1 ms or less | Incorporated | Green LED (lights up under stable light received condition or stable dark condition) | Red LED (lights up when the sensing output is ON) | - | Incorporated (Two units of sensors can be mounted close together.) | Continuously variable adjuster | IP67 (IEC) | -25 to +60 degrees -13 to +140 degrees Fahrenheit (No dew condensation or icing allowed), Storage: -30 to +70 degrees -22 to +158 degrees Fahrenheit | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 3,500 Lx or less at the light-receiving face | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure | 10 to 500 Hz frequency, 1.5 mm 0.059 in double amplitude (10 G max.) in X, Y and Z directions for two hours each | 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each | Red LED | 680 nm 0.027 mil | Enclosure: Die-cast zinc alloy Indicator cover: Polyethersulphone Lens: Acrylic | 0.15 mm2 5-core oil, heat and cold resistant cabtyre cable, 2 m 6.562 ft long | Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable | 75 g approx. | MS-RX-1 (Sensor mounting bracket): 1 set RF-230 (Reflector): 1 pc Adjusting screwdriver: 1 pc | | | |
| | EMC Directive, RoHS Directive | 0.1 to 3 m 0.328 to 9.843 ft (Note) The sensing range and the sensing object for the retroreflective type sensor are specified for the RF-230 reflector. Further, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m 0.328 ft away. | dia. 50 mm dia. 1.969 in or more opaque, translucent or specular object (Note) The sensing range and the sensing object for the retroreflective type sensor are specified for the RF-230 reflector. Further, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m 0.328 ft away. (Note) Make sure to confirm detection with an actual sensor before use. | - | 1 mm 0.039 in or less | 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less | 40 mA or less | NPN open-collector transistor - Maximum sink current: 100 mA - Applied voltage: 30 V DC or less (between sensing output and 0 V) - Residual voltage: 2 V or less (at 100 mA sink current), 1 V or less (at 16 mA sink current) | DC-12 or DC-13 | Switchable either Light-ON or Dark-ON | Incorporated | NPN open-collector transistor - Maximum sink current: 50 mA - Applied voltage: 30 V DC or less (between self-diagnosis output and 0 V) - Residual voltage: 1.5 V or less (at 50 mA sink current), 1 V or less (at 16 mA sink current) | ON under unstable sensing condition | - | 1 ms or less | Incorporated | Green LED (lights up under stable light received condition or stable dark condition) | Red LED (lights up when the sensing output is ON) | - | Incorporated (Two units of sensors can be mounted close together.) | Continuously variable adjuster | IP67 (IEC) | -25 to +60 degrees -13 to +140 degrees Fahrenheit (No dew condensation or icing allowed), Storage: -30 to +70 degrees -22 to +158 degrees Fahrenheit | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 3,500 Lx or less at the light-receiving face | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure | 10 to 500 Hz frequency, 1.5 mm 0.059 in double amplitude (10 G max.) in X, Y and Z directions for two hours each | 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each | Red LED | 680 nm 0.027 mil | Enclosure: Die-cast zinc alloy Indicator cover: Polyethersulphone Lens: Acrylic | 0.15 mm2 5-core oil, heat and cold resistant cabtyre cable, 5 m 16.404 ft long | Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable | | MS-RX-1 (Sensor mounting bracket): 1 set RF-230 (Reflector): 1 pc Adjusting screwdriver: 1 pc | | | |
| | EMC Directive, RoHS Directive | 200 mm 7.874 in (Note) The sensing range and the hysteresis of the diffuse reflective type sensor are specified for white non-glossy paper (200 x 200 mm 7.874 x 7.874 in) as the object. | Opaque, translucent or transparent object (Note) Make sure to confirm detection with an actual sensor before use. | 15 % or less of operation distance (Note) The sensing range and the hysteresis of the diffuse reflective type sensor are specified for white non-glossy paper (200 x 200 mm 7.874 x 7.874 in) as the object. | 0.5 mm 0.020 in or less | 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less | 40 mA or less | NPN open-collector transistor - Maximum sink current: 100 mA - Applied voltage: 30 V DC or less (between sensing output and 0 V) - Residual voltage: 2 V or less (at 100 mA sink current), 1 V or less (at 16 mA sink current) | DC-12 or DC-13 | Switchable either Light-ON or Dark-ON | Incorporated | NPN open-collector transistor - Maximum sink current: 50 mA - Applied voltage: 30 V DC or less (between self-diagnosis output and 0 V) - Residual voltage: 1.5 V or less (at 50 mA sink current), 1 V or less (at 16 mA sink current) | ON under unstable sensing condition | - | 1 ms or less | Incorporated | Green LED (lights up under stable light received condition or stable dark condition) | Red LED (lights up when the sensing output is ON) | - | Incorporated (Two units of sensors can be mounted close together.) | Continuously variable adjuster | IP67 (IEC) | -25 to +60 degrees -13 to +140 degrees Fahrenheit (No dew condensation or icing allowed), Storage: -30 to +70 degrees -22 to +158 degrees Fahrenheit | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 3,500 Lx or less at the light-receiving face | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure | 10 to 500 Hz frequency, 1.5 mm 0.059 in double amplitude (10 G max.) in X, Y and Z directions for two hours each | 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each | Red LED | 680 nm 0.027 mil | Enclosure: Die-cast zinc alloy Indicator cover: Polyethersulphone Lens: Polycarbonate | 0.15 mm2 5-core oil, heat and cold resistant cabtyre cable, 2 m 6.562 ft long | Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable | 75 g approx. | MS-RX-1 (Sensor mounting bracket): 1 set Adjusting screwdriver: 1 pc | | | |
| | EMC Directive, RoHS Directive | 500 mm 19.685 in | dia. 10 mm dia. 0.394 in or more opaque object | - | 0.5 mm 0.020 in or less | 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less | Emitter: 20 mA or less Receiver: 25 mA or less | NPN open-collector transistor - Maximum sink current: 100 mA - Applied voltage: 30 V DC or less (between sensing output and 0 V) - Residual voltage: 2 V or less (at 100 mA sink current), 1 V or less (at 16 mA sink current) | DC-12 or DC-13 | Switchable either Light-ON or Dark-ON | Incorporated | NPN open-collector transistor - Maximum sink current: 50 mA - Applied voltage: 30 V DC or less (between self-diagnosis output and 0 V) - Residual voltage: 1.5 V or less (at 50 mA sink current), 1 V or less (at 16 mA sink current) | ON under unstable sensing condition | - | 1 ms or less | Incorporated | Green LED (lights up under stable light received condition or stable dark condition) | Red LED (lights up when the sensing output is ON) | Red LED (lights up during beam emission) | - | Continuously variable adjuster | IP67 (IEC) | -25 to +60 degrees -13 to +140 degrees Fahrenheit (No dew condensation or icing allowed), Storage: -30 to +70 degrees -22 to +158 degrees Fahrenheit | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 3,500 Lx or less at the light-receiving face | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure | 10 to 500 Hz frequency, 1.5 mm 0.059 in double amplitude (10 G max.) in X, Y and Z directions for two hours each | 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each | Green LED | 570 nm 0.022 mil | Enclosure: Die-cast zinc alloy Indicator cover: Polyethersulphone Lens: Polycarbonate | Emitter: 0.15 mm2 3-core oil, heat and cold resistant cabtyre cable, 2 m 6.562 ft long Receiver: 0.15 mm2 4-core oil, heat and cold resistant cabtyre cable, 2 m 6.562 ft long | Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable (both emitter and receiver). | Emitter: 70 g approx Receiver: 70 g approx | MS-RX-1 (Sensor mounting bracket): 1 set for emitter and receiver Adjusting screwdriver: 1 pc | | | |
| | EMC Directive, RoHS Directive | 700 mm 27.559 in (Note) The sensing range and the hysteresis of the diffuse reflective type sensor are specified for white non-glossy paper (200 x 200 mm 7.874 x 7.874 in) as the object. | Opaque, translucent or transparent object (Note) Make sure to confirm detection with an actual sensor before use. | 15 % or less of operation distance (Note) The sensing range and the hysteresis of the diffuse reflective type sensor are specified for white non-glossy paper (200 x 200 mm 7.874 x 7.874 in) as the object. | 0.5 mm 0.020 in or less | 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less | 40 mA or less | NPN open-collector transistor - Maximum sink current: 100 mA - Applied voltage: 30 V DC or less (between sensing output and 0 V) - Residual voltage: 2 V or less (at 100 mA sink current), 1 V or less (at 16 mA sink current) | DC-12 or DC-13 | Switchable either Light-ON or Dark-ON | Incorporated | NPN open-collector transistor - Maximum sink current: 50 mA - Applied voltage: 30 V DC or less (between self-diagnosis output and 0 V) - Residual voltage: 1.5 V or less (at 50 mA sink current), 1 V or less (at 16 mA sink current) | ON under unstable sensing condition | - | 1 ms or less | Incorporated | Green LED (lights up under stable light received condition or stable dark condition) | Red LED (lights up when the sensing output is ON) | - | Incorporated (Two units of sensors can be mounted close together.) | Continuously variable adjuster | IP67 (IEC) | -25 to +60 degrees -13 to +140 degrees Fahrenheit (No dew condensation or icing allowed), Storage: -30 to +70 degrees -22 to +158 degrees Fahrenheit | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 3,500 Lx or less at the light-receiving face | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure | 10 to 500 Hz frequency, 1.5 mm 0.059 in double amplitude (10 G max.) in X, Y and Z directions for two hours each | 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each | Infrared LED | 880 nm 0.035 mil | Enclosure: Die-cast zinc alloy Indicator cover: Polyethersulphone Lens: Polycarbonate | 0.15 mm2 5-core oil, heat and cold resistant cabtyre cable, 2 m 6.562 ft long | Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable | 75 g approx. | MS-RX-1 (Sensor mounting bracket): 1 set Adjusting screwdriver: 1 pc | | | |
| | EMC Directive, RoHS Directive | 10 m 32.808 ft | dia. 10 mm dia. 0.394 in or more opaque object (Note) If slit masks (optional) are fitted, an object of 0.5 x 5 mm 0.020 x 0.197 in can be detected. | - | 0.5 mm 0.020 in or less | 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less | Emitter: 20 mA or less Receiver: 25 mA or less | NPN open-collector transistor - Maximum sink current: 100 mA - Applied voltage: 30 V DC or less (between sensing output and 0 V) - Residual voltage: 2 V or less (at 100 mA sink current), 1 V or less (at 16 mA sink current) | DC-12 or DC-13 | Switchable either Light-ON or Dark-ON | Incorporated | NPN open-collector transistor - Maximum sink current: 50 mA - Applied voltage: 30 V DC or less (between self-diagnosis output and 0 V) - Residual voltage: 1.5 V or less (at 50 mA sink current), 1 V or less (at 16 mA sink current) | ON under unstable sensing condition | - | 1 ms or less | Incorporated | Green LED (lights up under stable light received condition or stable dark condition) | Red LED (lights up when the sensing output is ON) | Red LED (lights up during beam emission) | - | Continuously variable adjuster | IP67 (IEC) | -25 to +60 degrees -13 to +140 degrees Fahrenheit (No dew condensation or icing allowed), Storage: -30 to +70 degrees -22 to +158 degrees Fahrenheit | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 3,500 Lx or less at the light-receiving face | 1,000 V AC for one min. between all supply terminals connected together and enclosure | 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure | 10 to 500 Hz frequency, 1.5 mm 0.059 in double amplitude (10 G max.) in X, Y and Z directions for two hours each | 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each | Infrared LED | 880 nm 0.035 mil | Enclosure: Die-cast zinc alloy Indicator cover: Polyethersulphone Lens: Polycarbonate | Emitter: 0.15 mm2 3-core oil, heat and cold resistant cabtyre cable, 2 m 6.562 ft long Receiver: 0.15 mm2 4-core oil, heat and cold resistant cabtyre cable, 2 m 6.562 ft long | Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable (both emitter and receiver). | Emitter: 70 g approx Receiver: 70 g approx | MS-RX-1 (Sensor mounting bracket): 1 set for emitter and receiver Adjusting screwdriver: 1 pc | | | |