Robust Photoelectric Sensor RX

Sturdy Photoelectric Sensor made of die-cast zinc alloy.

Part Number List

Results 24
Models table for series Robust Photoelectric Sensor RX
Part No.DatasheetCE Marking Directive ComplianceSensing Range Sensing Object HysteresisRepeatability (Perpendicular to Sensing Axis) Supply Voltage Current ConsumptionSensing Output Sensing Output: Utilization CategorySensing Output: Output OperationSensing Output: Short-Circuit ProtectionSelf-Diagnosis OutputSelf-Diagnosis Output: Output OperationSelf-Diagnosis Output: Short-Circuit ProtectionResponse TimeTest Input (Emission Halt) FunctionStability IndicatorOperation Indicator Emitting IndicatorAutomatic Interference Prevention FunctionSensitivity AdjusterProtectionAmbient TemperatureAmbient HumidityAmbient IlluminanceVoltage WithstandabilityInsulation Resistance Vibration ResistanceShock ResistanceEmitting Element (Modulated)Emitting Element (Modulated): Peak Emission WavelengthMaterialCableCable ExtensionWeight (Typ.)AccessoryRepeatability (Perpendicular to Sensing Axis)Emitting ElementProtective Tube Length
EMC Directive, RoHS Directive
500 mm 19.685 in
dia. 10 mm dia. 0.394 in or more opaque object
-
0.5 mm 0.020 in or less
12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less
Emitter: 20 mA or less
Receiver: 25 mA or less
NPN open-collector transistor
- Maximum sink current: 100 mA
- Applied voltage: 30 V DC or less (between sensing output and 0 V)
- Residual voltage: 2 V or less (at 100 mA sink current), 1 V or less (at 16 mA sink current)
DC-12 or DC-13
Switchable either Light-ON or Dark-ON
Incorporated
NPN open-collector transistor
- Maximum sink current: 50 mA
- Applied voltage: 30 V DC or less (between self-diagnosis output and 0 V)
- Residual voltage: 1.5 V or less (at 50 mA sink current), 1 V or less (at 16 mA sink current)
ON under unstable sensing condition
-
1 ms or less
Incorporated
Green LED (lights up under stable light received condition or stable dark condition)
Red LED (lights up when the sensing output is ON)
Red LED (lights up during beam emission)
-
Continuously variable adjuster
IP67 (IEC)
-25 to +60 degrees -13 to +140 degrees Fahrenheit (No dew condensation or icing allowed), Storage: -30 to +70 degrees -22 to +158 degrees Fahrenheit
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 3,500 Lx or less at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 500 Hz frequency, 1.5 mm 0.059 in double amplitude (10 G max.) in X, Y and Z directions for two hours each
500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each
Green LED
570 nm 0.022 mil
Enclosure: Die-cast zinc alloy
Indicator cover: Polyethersulphone
Lens: Polycarbonate
Emitter: 0.15 mm2 3-core oil, heat and cold resistant cabtyre cable, 2 m 6.562 ft long
Receiver: 0.15 mm2 4-core oil, heat and cold resistant cabtyre cable, 2 m 6.562 ft long
Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable (both emitter and receiver).
Emitter: 70 g approx
Receiver: 70 g approx
MS-RX-1 (Sensor mounting bracket): 1 set for emitter and receiver
Adjusting screwdriver: 1 pc
EMC Directive, RoHS Directive
10 m 32.808 ft
13 m 32.808 ft
16 m 32.808 ft
19 m 32.808 ft
12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less
Emitter: 20 mA or less
Receiver: 25 mA or less
NPN open-collector transistor
- Maximum sink current: 100 mA
- Applied voltage: 30 V DC or less (between sensing output and 0 V)
- Residual voltage: 2 V or less (at 100 mA sink current), 1 V or less (at 16 mA sink current)
DC-12 or DC-13
Switchable either Light-ON or Dark-ON
Incorporated
NPN open-collector transistor
- Maximum sink current: 50 mA
- Applied voltage: 30 V DC or less (between self-diagnosis output and 0 V)
- Residual voltage: 1.5 V or less (at 50 mA sink current), 1 V or less (at 16 mA sink current)
ON under unstable sensing condition
-
1 ms or less
Incorporated
Green LED (lights up under stable light received condition or stable dark condition)
Red LED (lights up when the sensing output is ON)
Red LED (lights up during beam emission)
-
Continuously variable adjuster
IP67 (IEC)
-25 to +60 degrees -13 to +140 degrees Fahrenheit (No dew condensation or icing allowed), Storage: -30 to +70 degrees -22 to +158 degrees Fahrenheit
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 3,500 Lx or less at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 500 Hz frequency, 1.5 mm 0.059 in double amplitude (10 G max.) in X, Y and Z directions for two hours each
500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each
Infrared LED
880 nm 0.035 mil
Enclosure: Die-cast zinc alloy
Indicator cover: Polyethersulphone
Lens: Polycarbonate
Emitter: 0.15 mm2 3-core oil, heat and cold resistant cabtyre cable, 5 m 16.404 ft long
Receiver: 0.15 mm2 4-core oil, heat and cold resistant cabtyre cable, 5 m 16.404 ft long
Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable (both emitter and receiver).
MS-RX-1 (Sensor mounting bracket): 1 set for emitter and receiver
Adjusting screwdriver: 1 pc
22 m 32.808 ft
EMC Directive, RoHS Directive
2 m 6.562 ft
dia. 10 mm dia. 0.394 in or more opaque object
-
0.5 mm 0.020 in or less
12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less
Emitter: 20 mA or less
Receiver: 25 mA or less
NPN open-collector transistor
- Maximum sink current: 100 mA
- Applied voltage: 30 V DC or less (between sensing output and 0 V)
- Residual voltage: 2 V or less (at 100 mA sink current), 1 V or less (at 16 mA sink current)
DC-12 or DC-13
Switchable either Light-ON or Dark-ON
Incorporated
NPN open-collector transistor
- Maximum sink current: 50 mA
- Applied voltage: 30 V DC or less (between self-diagnosis output and 0 V)
- Residual voltage: 1.5 V or less (at 50 mA sink current), 1 V or less (at 16 mA sink current)
ON under unstable sensing condition
-
1 ms or less
Incorporated
Green LED (lights up under stable light received condition or stable dark condition)
Red LED (lights up when the sensing output is ON)
Red LED (lights up during beam emission)
-
Continuously variable adjuster
IP67 (IEC)
-25 to +60 degrees -13 to +140 degrees Fahrenheit (No dew condensation or icing allowed), Storage: -30 to +70 degrees -22 to +158 degrees Fahrenheit
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 3,500 Lx or less at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 500 Hz frequency, 1.5 mm 0.059 in double amplitude (10 G max.) in X, Y and Z directions for two hours each
500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each
Red LED
680 nm 0.027 mil
Enclosure: Die-cast zinc alloy
Indicator cover: Polyethersulphone
Lens: Polycarbonate
Emitter: 0.15 mm2 3-core oil, heat and cold resistant cabtyre cable, 5 m 16.404 ft long
Receiver: 0.15 mm2 4-core oil, heat and cold resistant cabtyre cable, 5 m 16.404 ft long
Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable (both emitter and receiver).
MS-RX-1 (Sensor mounting bracket): 1 set for emitter and receiver
Adjusting screwdriver: 1 pc
EMC Directive, RoHS Directive
200 mm 7.874 in
(Note) The sensing range and the hysteresis of the diffuse reflective type sensor are specified for white non-glossy paper (200 x 200 mm 7.874 x 7.874 in) as the object.
Opaque, translucent or transparent object
(Note) Make sure to confirm detection with an actual sensor before use.
15 % or less of operation distance
(Note) The sensing range and the hysteresis of the diffuse reflective type sensor are specified for white non-glossy paper (200 x 200 mm 7.874 x 7.874 in) as the object.
0.5 mm 0.020 in or less
12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less
40 mA or less
NPN open-collector transistor
- Maximum sink current: 100 mA
- Applied voltage: 30 V DC or less (between sensing output and 0 V)
- Residual voltage: 2 V or less (at 100 mA sink current), 1 V or less (at 16 mA sink current)
DC-12 or DC-13
Switchable either Light-ON or Dark-ON
Incorporated
NPN open-collector transistor
- Maximum sink current: 50 mA
- Applied voltage: 30 V DC or less (between self-diagnosis output and 0 V)
- Residual voltage: 1.5 V or less (at 50 mA sink current), 1 V or less (at 16 mA sink current)
ON under unstable sensing condition
-
1 ms or less
Incorporated
Green LED (lights up under stable light received condition or stable dark condition)
Red LED (lights up when the sensing output is ON)
-
Incorporated (Two units of sensors can be mounted close together.)
Continuously variable adjuster
IP67 (IEC)
-25 to +60 degrees -13 to +140 degrees Fahrenheit (No dew condensation or icing allowed), Storage: -30 to +70 degrees -22 to +158 degrees Fahrenheit
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 3,500 Lx or less at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 500 Hz frequency, 1.5 mm 0.059 in double amplitude (10 G max.) in X, Y and Z directions for two hours each
500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each
Red LED
680 nm 0.027 mil
Enclosure: Die-cast zinc alloy
Indicator cover: Polyethersulphone
Lens: Polycarbonate
0.15 mm2 5-core oil, heat and cold resistant cabtyre cable, 2 m 6.562 ft long
Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable
75 g approx.
MS-RX-1 (Sensor mounting bracket): 1 set
Adjusting screwdriver: 1 pc
EMC Directive, RoHS Directive
700 mm 27.559 in
(Note) The sensing range and the hysteresis of the diffuse reflective type sensor are specified for white non-glossy paper (200 x 200 mm 7.874 x 7.874 in) as the object.
Opaque, translucent or transparent object
(Note) Make sure to confirm detection with an actual sensor before use.
15 % or less of operation distance
(Note) The sensing range and the hysteresis of the diffuse reflective type sensor are specified for white non-glossy paper (200 x 200 mm 7.874 x 7.874 in) as the object.
0.5 mm 0.020 in or less
12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less
40 mA or less
NPN open-collector transistor
- Maximum sink current: 100 mA
- Applied voltage: 30 V DC or less (between sensing output and 0 V)
- Residual voltage: 2 V or less (at 100 mA sink current), 1 V or less (at 16 mA sink current)
DC-12 or DC-13
Switchable either Light-ON or Dark-ON
Incorporated
NPN open-collector transistor
- Maximum sink current: 50 mA
- Applied voltage: 30 V DC or less (between self-diagnosis output and 0 V)
- Residual voltage: 1.5 V or less (at 50 mA sink current), 1 V or less (at 16 mA sink current)
ON under unstable sensing condition
-
1 ms or less
Incorporated
Green LED (lights up under stable light received condition or stable dark condition)
Red LED (lights up when the sensing output is ON)
-
Incorporated (Two units of sensors can be mounted close together.)
Continuously variable adjuster
IP67 (IEC)
-25 to +60 degrees -13 to +140 degrees Fahrenheit (No dew condensation or icing allowed), Storage: -30 to +70 degrees -22 to +158 degrees Fahrenheit
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 3,500 Lx or less at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 500 Hz frequency, 1.5 mm 0.059 in double amplitude (10 G max.) in X, Y and Z directions for two hours each
500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each
Infrared LED
880 nm 0.035 mil
Enclosure: Die-cast zinc alloy
Indicator cover: Polyethersulphone
Lens: Polycarbonate
0.15 mm2 5-core oil, heat and cold resistant cabtyre cable, 2 m 6.562 ft long
Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable
75 g approx.
MS-RX-1 (Sensor mounting bracket): 1 set
Adjusting screwdriver: 1 pc
EMC Directive, RoHS Directive
10 m 32.808 ft
dia. 10 mm dia. 0.394 in or more opaque object
(Note) If slit masks (optional) are fitted, an object of 0.5 x 5 mm 0.020 x 0.197 in can be detected.
-
0.5 mm 0.020 in or less
12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less
Emitter: 20 mA or less
Receiver: 25 mA or less
NPN open-collector transistor
- Maximum sink current: 100 mA
- Applied voltage: 30 V DC or less (between sensing output and 0 V)
- Residual voltage: 2 V or less (at 100 mA sink current), 1 V or less (at 16 mA sink current)
DC-12 or DC-13
Switchable either Light-ON or Dark-ON
Incorporated
NPN open-collector transistor
- Maximum sink current: 50 mA
- Applied voltage: 30 V DC or less (between self-diagnosis output and 0 V)
- Residual voltage: 1.5 V or less (at 50 mA sink current), 1 V or less (at 16 mA sink current)
ON under unstable sensing condition
-
1 ms or less
Incorporated
Green LED (lights up under stable light received condition or stable dark condition)
Red LED (lights up when the sensing output is ON)
Red LED (lights up during beam emission)
-
Continuously variable adjuster
IP67 (IEC)
-25 to +60 degrees -13 to +140 degrees Fahrenheit (No dew condensation or icing allowed), Storage: -30 to +70 degrees -22 to +158 degrees Fahrenheit
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 3,500 Lx or less at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 500 Hz frequency, 1.5 mm 0.059 in double amplitude (10 G max.) in X, Y and Z directions for two hours each
500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each
Infrared LED
880 nm 0.035 mil
Enclosure: Die-cast zinc alloy
Indicator cover: Polyethersulphone
Lens: Polycarbonate
Emitter: 0.15 mm2 3-core oil, heat and cold resistant cabtyre cable, 2 m 6.562 ft long
Receiver: 0.15 mm2 4-core oil, heat and cold resistant cabtyre cable, 2 m 6.562 ft long
Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable (both emitter and receiver).
Emitter: 70 g approx
Receiver: 70 g approx
MS-RX-1 (Sensor mounting bracket): 1 set for emitter and receiver
Adjusting screwdriver: 1 pc
EMC Directive, RoHS Directive
5 m 16.404 ft
dia. 10 mm dia. 0.394 in or more opaque object
12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less
Emitter: 20 mA or less
Receiver: 25 mA or less
NPN open-collector transistor
- Maximum sink current: 100 mA
- Applied voltage: 30 V DC or less (between sensing output and 0 V)
- Residual voltage: 2 V or less (at 100 mA sink current), 1 V or less (at 16 mA sink current)
Switchable either Light-ON or Dark-ON
Incorporated
NPN open-collector transistor
- Maximum sink current: 50 mA
- Applied voltage: 30 V DC or less (between self-diagnosis output and 0 V)
- Residual voltage: 1.5 V or less (at 50 mA sink current), 1 V or less (at 16 mA sink current)
ON under unstable sensing condition
-
1 ms or less
Incorporated
Green LED (lights up under stable light received condition or stable dark condition)
Red LED (lights up when the sensing output is ON)
Red LED (lights up during beam emission)
Continuously variable adjuster
IP67 (IEC), IP67g (JEM)
-25 to +60 degrees -13 to +140 degrees Fahrenheit (No dew condensation or icing allowed), Storage: -30 to +70 degrees -22 to +158 degrees Fahrenheit
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 3,500 Lx or less at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 500 Hz frequency, 1.5 mm 0.059 in double amplitude (10 G max.) in X, Y and Z directions for two hours each
500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each
Enclosure: Die-cast zinc alloy (Fluorine resin coating)
Indicator cover: Polyethersulphone
Lens: Polyalylate, Protective tube
sheath: Oil resistant PVC
0.15 mm2 4-core (emitter: 3-core) oil, heat and cold resistant cabtyre cable
Extension up to total 100 m 328.084 ft is possible for both emitter and receiver with 0.3 mm2, or more, cable.
Emitter: 175 g approx
Receiver: 175 g approx
MS-RX-2 (Sensor mounting bracket): 1 set for emitter and receiver
Adjusting screwdriver: 1 pc
0.5 mm 0.020 in or less
Infrared LED (Peak emission wavelength: 880 nm 0.035 mil, modulated)
1 m 3.281 ft
EMC Directive, RoHS Directive
5 m 16.404 ft
dia. 10 mm dia. 0.394 in or more opaque object
12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less
Emitter: 20 mA or less
Receiver: 25 mA or less
NPN open-collector transistor
- Maximum sink current: 100 mA
- Applied voltage: 30 V DC or less (between sensing output and 0 V)
- Residual voltage: 2 V or less (at 100 mA sink current), 1 V or less (at 16 mA sink current)
Switchable either Light-ON or Dark-ON
Incorporated
NPN open-collector transistor
- Maximum sink current: 50 mA
- Applied voltage: 30 V DC or less (between self-diagnosis output and 0 V)
- Residual voltage: 1.5 V or less (at 50 mA sink current), 1 V or less (at 16 mA sink current)
ON under unstable sensing condition
-
1 ms or less
Incorporated
Green LED (lights up under stable light received condition or stable dark condition)
Red LED (lights up when the sensing output is ON)
Red LED (lights up during beam emission)
Continuously variable adjuster
IP67 (IEC), IP67g (JEM)
-25 to +60 degrees -13 to +140 degrees Fahrenheit (No dew condensation or icing allowed), Storage: -30 to +70 degrees -22 to +158 degrees Fahrenheit
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 3,500 Lx or less at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 500 Hz frequency, 1.5 mm 0.059 in double amplitude (10 G max.) in X, Y and Z directions for two hours each
500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each
Enclosure: Die-cast zinc alloy (Fluorine resin coating)
Indicator cover: Polyethersulphone
Lens: Polyalylate, Protective tube
sheath: Oil resistant PVC
0.15 mm2 4-core (emitter: 3-core) oil, heat and cold resistant cabtyre cable
Extension up to total 100 m 328.084 ft is possible for both emitter and receiver with 0.3 mm2, or more, cable.
Emitter: 265 g approx
Receiver: 265 g approx
MS-RX-2 (Sensor mounting bracket): 1 set for emitter and receiver
Adjusting screwdriver: 1 pc
0.5 mm 0.020 in or less
Infrared LED (Peak emission wavelength: 880 nm 0.035 mil, modulated)
2 m 6.562 ft
EMC Directive, RoHS Directive
0.1 to 3 m 0.328 to 9.843 ft
(Note) The sensing range and the sensing object for the retroreflective type sensor are specified for the RF-230 reflector. Further, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m 0.328 ft away.
dia. 50 mm dia. 1.969 in or more opaque, translucent or specular object
(Note) The sensing range and the sensing object for the retroreflective type sensor are specified for the RF-230 reflector. Further, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m 0.328 ft away.
(Note) Make sure to confirm detection with an actual sensor before use.
-
1 mm 0.039 in or less
12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less
40 mA or less
NPN open-collector transistor
- Maximum sink current: 100 mA
- Applied voltage: 30 V DC or less (between sensing output and 0 V)
- Residual voltage: 2 V or less (at 100 mA sink current), 1 V or less (at 16 mA sink current)
DC-12 or DC-13
Switchable either Light-ON or Dark-ON
Incorporated
NPN open-collector transistor
- Maximum sink current: 50 mA
- Applied voltage: 30 V DC or less (between self-diagnosis output and 0 V)
- Residual voltage: 1.5 V or less (at 50 mA sink current), 1 V or less (at 16 mA sink current)
ON under unstable sensing condition
-
1 ms or less
Incorporated
Green LED (lights up under stable light received condition or stable dark condition)
Red LED (lights up when the sensing output is ON)
-
Incorporated (Two units of sensors can be mounted close together.)
Continuously variable adjuster
IP67 (IEC)
-25 to +60 degrees -13 to +140 degrees Fahrenheit (No dew condensation or icing allowed), Storage: -30 to +70 degrees -22 to +158 degrees Fahrenheit
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 3,500 Lx or less at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 500 Hz frequency, 1.5 mm 0.059 in double amplitude (10 G max.) in X, Y and Z directions for two hours each
500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each
Red LED
680 nm 0.027 mil
Enclosure: Die-cast zinc alloy
Indicator cover: Polyethersulphone
Lens: Acrylic
0.15 mm2 5-core oil, heat and cold resistant cabtyre cable, 2 m 6.562 ft long
Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable
75 g approx.
MS-RX-1 (Sensor mounting bracket): 1 set
RF-230 (Reflector): 1 pc
Adjusting screwdriver: 1 pc
EMC Directive, RoHS Directive
0.1 to 3 m 0.328 to 9.843 ft
(Note) The sensing range and the sensing object for the retroreflective type sensor are specified for the RF-230 reflector. Further, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m 0.328 ft away.
dia. 50 mm dia. 1.969 in or more opaque, translucent or specular object
(Note) The sensing range and the sensing object for the retroreflective type sensor are specified for the RF-230 reflector. Further, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m 0.328 ft away.
(Note) Make sure to confirm detection with an actual sensor before use.
-
1 mm 0.039 in or less
12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less
40 mA or less
NPN open-collector transistor
- Maximum sink current: 100 mA
- Applied voltage: 30 V DC or less (between sensing output and 0 V)
- Residual voltage: 2 V or less (at 100 mA sink current), 1 V or less (at 16 mA sink current)
DC-12 or DC-13
Switchable either Light-ON or Dark-ON
Incorporated
NPN open-collector transistor
- Maximum sink current: 50 mA
- Applied voltage: 30 V DC or less (between self-diagnosis output and 0 V)
- Residual voltage: 1.5 V or less (at 50 mA sink current), 1 V or less (at 16 mA sink current)
ON under unstable sensing condition
-
1 ms or less
Incorporated
Green LED (lights up under stable light received condition or stable dark condition)
Red LED (lights up when the sensing output is ON)
-
Incorporated (Two units of sensors can be mounted close together.)
Continuously variable adjuster
IP67 (IEC)
-25 to +60 degrees -13 to +140 degrees Fahrenheit (No dew condensation or icing allowed), Storage: -30 to +70 degrees -22 to +158 degrees Fahrenheit
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 3,500 Lx or less at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure
20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 500 Hz frequency, 1.5 mm 0.059 in double amplitude (10 G max.) in X, Y and Z directions for two hours each
500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each
Red LED
680 nm 0.027 mil
Enclosure: Die-cast zinc alloy
Indicator cover: Polyethersulphone
Lens: Acrylic
0.15 mm2 5-core oil, heat and cold resistant cabtyre cable, 5 m 16.404 ft long
Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable
MS-RX-1 (Sensor mounting bracket): 1 set
RF-230 (Reflector): 1 pc
Adjusting screwdriver: 1 pc