| | Agent, such as Sulfuric acid, Hydrochloric acid, Phosphoric acid or Ammonia etc. Note : Highly viscous liquid may not be detected stably. Note : The agents mentioned above are examples. For details, please contact our office. Note : PVC mounting bracket may not be used depending on type or viscosity etc. of the agent. For details, please contact our office. | | 12 to 24 V DC ± 10 % Ripple P-P 10 % or less | 15 mA or less | NPN open-collector transistor - Maximum sink current: 50 mA - Applied voltage: 30 V DC or less (between output and 0 V) - Residual voltage: 1.0 V or less (at 50 mA sink current), 0.4 V or less (at 16 mA sink current) | In normal state: ON, When leak detected or the sensor is mounted improperly: OFF | Incorporated | 50 ms or less | | | | | Red LED (lights up when the leak liquid is detected, or the sensor is mounted improperly) | Green LED (lights up when the sensor is mounted properly) | IP67 (IEC) | -10 to +60 ℃ +14 to +140 ℉ (No dew condensation or icing allowed), Storage: -20 to +70 ℃ - 4 to +158 ℉ Note : Liquid being detected should also be kept within the rated ambient temperature range. | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 1,000 ℓx or less at the light-receiving face | Infrared LED (non-modulated) | Enclosure: PFA | 0.1 mm2 3-core PFA cabtyre cable, 3 m 9.843 ft long | Extension up to total 50 m 164.042 ft is possible with 0.3 mm2, or more, cable. | Net weight: 60 g approx. | MS-EX-F6-1(PFA mounting bracket): 1 pc. |
| | Water, Fluorinert™ Note:Highly viscous liquid may not be detected stably. Note:Fluorinert is the world wide trademark of 3M. | | 12 to 24 V DC ± 10 % Ripple P-P 10 % or less | 10 mA or less(PNP output type: 15 mA or less) | NPN open-collector transistor - Maximum sink current: 50 mA - Applied voltage: 30 V DC or less (between output and 0 V) - Residual voltage: 1.0 V or less (at 50 mA sink current), 0.4 V or less (at 16 mA sink current) | In normal state: ON, When leak detected or the sensor is mounted improperly: OFF | Incorporated | 50 ms or less | | | | | Red LED (lights up when the leak liquid is detected, or the sensor is mounted improperly) | Green LED (lights up when the sensor is mounted properly) | IP67 (IEC) | -10 to +60 ℃ +14 to +140 ℉ (No dew condensation or icing allowed), Storage: -20 to +70 ℃ - 4 to +158 ℉ Note : Liquid being detected should also be kept within the rated ambient temperature range. | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 1,000 ℓx or less at the light-receiving face | Infrared LED (non-modulated) | Enclosure: Polypropylene | | Extension up to total 50 m 164.042 ft is possible with 0.3 mm2, or more, cable. | | MS-EX-F7-1(SUS mounting bracket): 1 pc. Note : The mounting bracket for EX-F71(-PN) is not interchangeable with that of EX-F72(-PN) due to the different sensitivity settings of each sensor. |
| | Water, Fluorinert™ Note:Highly viscous liquid may not be detected stably. Note:Fluorinert is the world wide trademark of 3M. | | 12 to 24 V DC ± 10 % Ripple P-P 10 % or less | 10 mA or less(PNP output type: 15 mA or less) | NPN open-collector transistor - Maximum sink current: 50 mA - Applied voltage: 30 V DC or less (between output and 0 V) - Residual voltage: 1.0 V or less (at 50 mA sink current), 0.4 V or less (at 16 mA sink current) | In normal state: ON, When leak detected or the sensor is mounted improperly: OFF | Incorporated | 50 ms or less | | | | | Red LED (lights up when the leak liquid is detected, or the sensor is mounted improperly) | Green LED (lights up when the sensor is mounted properly) | IP67 (IEC) | -10 to +60 ℃ +14 to +140 ℉ (No dew condensation or icing allowed), Storage: -20 to +70 ℃ - 4 to +158 ℉ Note : Liquid being detected should also be kept within the rated ambient temperature range. | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 1,000 ℓx or less at the light-receiving face | Infrared LED (non-modulated) | Enclosure: Polypropylene | 0.1 mm2 3-core PVC cabtyre cable, 2 m 6.562 ft long | Extension up to total 50 m 164.042 ft is possible with 0.3 mm2, or more, cable. | Net weight: 25 g approx. | MS-EX-F7-1(SUS mounting bracket): 1 pc. Note : The mounting bracket for EX-F71(-PN) is not interchangeable with that of EX-F72(-PN) due to the different sensitivity settings of each sensor. |
| | Agent, such as Sulfuric acid, Hydrochloric acid, Phosphoric acid or Ammonia etc. Note : Highly viscous liquid may not be detected stably. Note : The agents mentioned above are examples. For details, please contact our office. Note : PVC mounting bracket may not be used depending on type or viscosity etc. of the agent. For details, please contact our office. | | 12 to 24 V DC ± 10 % Ripple P-P 10 % or less | 15 mA or less | NPN open-collector transistor - Maximum sink current: 50 mA - Applied voltage: 30 V DC or less (between output and 0 V) - Residual voltage: 1.0 V or less (at 50 mA sink current), 0.4 V or less (at 16 mA sink current) | In normal state: ON, When leak detected or the sensor is mounted improperly: OFF | Incorporated | 50 ms or less | | | | | Red LED (lights up when the leak liquid is detected, or the sensor is mounted improperly) | Green LED (lights up when the sensor is mounted properly) | IP67 (IEC) | -10 to +60 ℃ +14 to +140 ℉ (No dew condensation or icing allowed), Storage: -20 to +70 ℃ - 4 to +158 ℉ Note : Liquid being detected should also be kept within the rated ambient temperature range. | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 1,000 ℓx or less at the light-receiving face | Infrared LED (non-modulated) | Enclosure: PFA | | Extension up to total 50 m 164.042 ft is possible with 0.3 mm2, or more, cable. | Net weight: 60 g approx. | MS-EX-F6-2(PVC mounting bracket): 1 pc. |
| | Agent, such as Sulfuric acid, Hydrochloric acid, Phosphoric acid or Ammonia etc. Note : Highly viscous liquid may not be detected stably. Note : The agents mentioned above are examples. For details, please contact our office. Note : PVC mounting bracket may not be used depending on type or viscosity etc. of the agent. For details, please contact our office. | | 12 to 24 V DC ± 10 % Ripple P-P 10 % or less | 15 mA or less | PNP open-collector transistor - Maximum source current: 50 mA - Applied voltage: 30 V DC or less (between output and +V) - Residual voltage: 1.0 V or less (at 50 mA source current), 0.4 V or less (at 16 mA source current) | In normal state: ON, When leak detected or the sensor is mounted improperly: OFF | Incorporated | 50 ms or less | | | | | Red LED (lights up when the leak liquid is detected, or the sensor is mounted improperly) | Green LED (lights up when the sensor is mounted properly) | IP67 (IEC) | -10 to +60 ℃ +14 to +140 ℉ (No dew condensation or icing allowed), Storage: -20 to +70 ℃ - 4 to +158 ℉ Note : Liquid being detected should also be kept within the rated ambient temperature range. | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 1,000 ℓx or less at the light-receiving face | Infrared LED (non-modulated) | Enclosure: PFA | | Extension up to total 50 m 164.042 ft is possible with 0.3 mm2, or more, cable. | | MS-EX-F6-2(PVC mounting bracket): 1 pc. |
| | Agent, such as Sulfuric acid, Hydrochloric acid, Phosphoric acid or Ammonia etc. Note : Highly viscous liquid may not be detected stably. Note : The agents mentioned above are examples. For details, please contact our office. Note : PVC mounting bracket may not be used depending on type or viscosity etc. of the agent. For details, please contact our office. | | 12 to 24 V DC ± 10 % Ripple P-P 10 % or less | 15 mA or less | PNP open-collector transistor - Maximum source current: 50 mA - Applied voltage: 30 V DC or less (between output and +V) - Residual voltage: 1.0 V or less (at 50 mA source current), 0.4 V or less (at 16 mA source current) | In normal state: ON, When leak detected or the sensor is mounted improperly: OFF | Incorporated | 50 ms or less | | | | | Red LED (lights up when the leak liquid is detected, or the sensor is mounted improperly) | Green LED (lights up when the sensor is mounted properly) | IP67 (IEC) | -10 to +60 ℃ +14 to +140 ℉ (No dew condensation or icing allowed), Storage: -20 to +70 ℃ - 4 to +158 ℉ Note : Liquid being detected should also be kept within the rated ambient temperature range. | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 1,000 ℓx or less at the light-receiving face | Infrared LED (non-modulated) | Enclosure: PFA | | Extension up to total 50 m 164.042 ft is possible with 0.3 mm2, or more, cable. | Net weight: 60 g approx. | MS-EX-F6-1(PFA mounting bracket): 1 pc. |
| | | SL-CP1 | 12 to 24 V DC ± 10 % Ripple P-P 10 % or less | 50 mA or less (for the unit itself), 135 mA or less (including the sensor input current when all outputs of sensors are ON) | Relay contact 1a - Switching capacity: 30 V 1 A DC (resistive load) - Min. applied load: 10 mV 10 μA DC - Electrical lifetime: 100,000 switching operations or more (rated load, switching frequency 20 operations/min.) - Mechanical lifetime: 50 million switching operations or more (switching frequency 180 operations/min.) | The output relay is ON when the input signal from the sensor is ON Note : Even with only one leak detection sensor connected, an OFF signal is output if the sensor detects liquid leakage, or if the unit has been installed incorrectly. | | 5 ms or less (excluding the response time of the sensor) | 8 Nos. | Green LED x 8 (light up when the sensor is connected to each channel and the connection setting switch is set to ON) | Red LED x 8 (light up when the leak liquid is detected by a sensor connected to each channel or a sensor is mounted improperly) | Orange LED (lights up when the output relay is ON (normal)) | | | | -10 to +60 ℃ +14 to +140 ℉ (No dew condensation or icing allowed), Storage: -20 to +70 ℃ - 4 to +158 ℉ | 35 to 85 % RH, Storage: 35 to 85 % RH | | | Enclosure: ABS, Unit mounting base: POM, Terminal part: PBT | 0.2 mm2 4-core cabtyre cable, 2 m 6.562 ft long | Extension up to total less than 10 m 32.808 ft is possible, with 0.3 mm2, or more, cable. | Net weight: 85 g approx. | SL-CP1 (Snap male connector): 8 pcs., MS-SL-2 (Unit mounting base): 1 pc. |
| | Water, Fluorinert™ Note:Highly viscous liquid may not be detected stably. Note:Fluorinert is the world wide trademark of 3M. | | 12 to 24 V DC ± 10 % Ripple P-P 10 % or less | 10 mA or less(PNP output type: 15 mA or less) | PNP open-collector transistor - Maximum source current: 50 mA - Applied voltage: 30 V DC or less (between output and +V) - Residual voltage: 1.0 V or less (at 50 mA source current), 0.4 V or less (at 16 mA source current) | In normal state: ON, When leak detected or the sensor is mounted improperly: OFF | Incorporated | 50 ms or less | | | | | Red LED (lights up when the leak liquid is detected, or the sensor is mounted improperly) | Green LED (lights up when the sensor is mounted properly) | IP67 (IEC) | -10 to +60 ℃ +14 to +140 ℉ (No dew condensation or icing allowed), Storage: -20 to +70 ℃ - 4 to +158 ℉ Note : Liquid being detected should also be kept within the rated ambient temperature range. | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 1,000 ℓx or less at the light-receiving face | Infrared LED (non-modulated) | Enclosure: Polypropylene | | Extension up to total 50 m 164.042 ft is possible with 0.3 mm2, or more, cable. | | MS-EX-F7-1(SUS mounting bracket): 1 pc. Note : The mounting bracket for EX-F71(-PN) is not interchangeable with that of EX-F72(-PN) due to the different sensitivity settings of each sensor. |
| | Water, Fluorinert™ Note:Highly viscous liquid may not be detected stably. Note:Fluorinert is the world wide trademark of 3M. | | 12 to 24 V DC ± 10 % Ripple P-P 10 % or less | 10 mA or less(PNP output type: 15 mA or less) | PNP open-collector transistor - Maximum source current: 50 mA - Applied voltage: 30 V DC or less (between output and +V) - Residual voltage: 1.0 V or less (at 50 mA source current), 0.4 V or less (at 16 mA source current) | In normal state: ON, When leak detected or the sensor is mounted improperly: OFF | Incorporated | 50 ms or less | | | | | Red LED (lights up when the leak liquid is detected, or the sensor is mounted improperly) | Green LED (lights up when the sensor is mounted properly) | IP67 (IEC) | -10 to +60 ℃ +14 to +140 ℉ (No dew condensation or icing allowed), Storage: -20 to +70 ℃ - 4 to +158 ℉ Note : Liquid being detected should also be kept within the rated ambient temperature range. | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 1,000 ℓx or less at the light-receiving face | Infrared LED (non-modulated) | Enclosure: Polypropylene | 0.1 mm2 3-core PVC cabtyre cable, 2 m 6.562 ft long | Extension up to total 50 m 164.042 ft is possible with 0.3 mm2, or more, cable. | Net weight: 25 g approx. | MS-EX-F7-1(SUS mounting bracket): 1 pc. Note : The mounting bracket for EX-F71(-PN) is not interchangeable with that of EX-F72(-PN) due to the different sensitivity settings of each sensor. |
| | Agent, such as Sulfuric acid, Hydrochloric acid, Phosphoric acid or Ammonia etc. Note : Highly viscous liquid may not be detected stably. Note : The agents mentioned above are examples. For details, please contact our office. Note : PVC mounting bracket may not be used depending on type or viscosity etc. of the agent. For details, please contact our office. | | 12 to 24 V DC ± 10 % Ripple P-P 10 % or less | 15 mA or less | PNP open-collector transistor - Maximum source current: 50 mA - Applied voltage: 30 V DC or less (between output and +V) - Residual voltage: 1.0 V or less (at 50 mA source current), 0.4 V or less (at 16 mA source current) | In normal state: ON, When leak detected or the sensor is mounted improperly: OFF | Incorporated | 50 ms or less | | | | | Red LED (lights up when the leak liquid is detected, or the sensor is mounted improperly) | Green LED (lights up when the sensor is mounted properly) | IP67 (IEC) | -10 to +60 ℃ +14 to +140 ℉ (No dew condensation or icing allowed), Storage: -20 to +70 ℃ - 4 to +158 ℉ Note : Liquid being detected should also be kept within the rated ambient temperature range. | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 1,000 ℓx or less at the light-receiving face | Infrared LED (non-modulated) | Enclosure: PFA | | Extension up to total 50 m 164.042 ft is possible with 0.3 mm2, or more, cable. | | MS-EX-F6-1(PFA mounting bracket): 1 pc. |