Item | Performance characteristics |
---|---|
CE Marking Directive Compliance | EMC Directive, RoHS Directive |
Sensing Range | 200 mm 7.874 in (Note) The sensing range and the hysteresis of the diffuse reflective type sensor are specified for white non-glossy paper (200 x 200 mm 7.874 x 7.874 in) as the object. |
Sensing Object | Opaque, translucent or transparent object (Note) Make sure to confirm detection with an actual sensor before use. |
Hysteresis | 15 % or less of operation distance (Note) The sensing range and the hysteresis of the diffuse reflective type sensor are specified for white non-glossy paper (200 x 200 mm 7.874 x 7.874 in) as the object. |
Repeatability (Perpendicular to Sensing Axis) | 0.5 mm 0.020 in or less |
Supply Voltage | 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less |
Current Consumption | 40 mA or less |
Sensing Output | NPN open-collector transistor - Maximum sink current: 100 mA - Applied voltage: 30 V DC or less (between sensing output and 0 V) - Residual voltage: 2 V or less (at 100 mA sink current), 1 V or less (at 16 mA sink current) |
Sensing Output: Utilization Category | DC-12 or DC-13 |
Sensing Output: Output Operation | Switchable either Light-ON or Dark-ON |
Sensing Output: Short-Circuit Protection | Incorporated |
Self-Diagnosis Output | NPN open-collector transistor - Maximum sink current: 50 mA - Applied voltage: 30 V DC or less (between self-diagnosis output and 0 V) - Residual voltage: 1.5 V or less (at 50 mA sink current), 1 V or less (at 16 mA sink current) |
Self-Diagnosis Output: Output Operation | ON under unstable sensing condition |
Self-Diagnosis Output: Short-Circuit Protection | - |
Response Time | 1 ms or less |
Test Input (Emission Halt) Function | Incorporated |
Stability Indicator | Green LED (lights up under stable light received condition or stable dark condition) |
Operation Indicator | Red LED (lights up when the sensing output is ON) |
Emitting Indicator | - |
Automatic Interference Prevention Function | Incorporated (Two units of sensors can be mounted close together.) |
Sensitivity Adjuster | Continuously variable adjuster |
Protection | IP67 (IEC) |
Ambient Temperature | -25 to +60 degrees -13 to +140 degrees Fahrenheit (No dew condensation or icing allowed), Storage: -30 to +70 degrees -22 to +158 degrees Fahrenheit |
Ambient Humidity | 35 to 85 % RH, Storage: 35 to 85 % RH |
Ambient Illuminance | Incandescent light: 3,500 Lx or less at the light-receiving face |
Voltage Withstandability | 1,000 V AC for one min. between all supply terminals connected together and enclosure |
Insulation Resistance | 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure |
Vibration Resistance | 10 to 500 Hz frequency, 1.5 mm 0.059 in double amplitude (10 G max.) in X, Y and Z directions for two hours each |
Shock Resistance | 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each |
Emitting Element (Modulated) | Red LED |
Emitting Element (Modulated): Peak Emission Wavelength | 680 nm 0.027 mil |
Material | Enclosure: Die-cast zinc alloy Indicator cover: Polyethersulphone Lens: Polycarbonate |
Cable | 0.15 mm2 5-core oil, heat and cold resistant cabtyre cable, 2 m 6.562 ft long |
Cable Extension | Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable |
Weight (Typ.) | 75 g approx. |
Accessory | MS-RX-1 (Sensor mounting bracket): 1 set Adjusting screwdriver: 1 pc |