Specification

Specifications table for model SH-22
ItemPerformance characteristics
Applicable AmplifiersSU-7 series
Sensing Range 50 mm 1.969 in(Note)
Note 2 : The sensing range and the hysteresis of the diffuse reflective type sensor are specified for white non-glossy paper (50 x 50 mm 1.969 x 1.969 in) as the object.
Sensing Object Min. ø0.3 mm ø0.012 in copper wire (with 3 mm 0.118 in setting distance and at the max sensitivity)
Hysteresis15 % or less of operation distance
Note : The sensing range and the hysteresis of the diffuse reflective type sensor are specified for white non-glossy paper (50 x 50 mm 1.969 x 1.969 in) as the object.
Repeatability (Perpendicular to Sensing Axis) 0.15 mm 0.006 in or less
Operation Indicator -
ProtectionIP62 (IEC)
Ambient Temperature-10 to +60 ℃ +14 to 140 ℉ (No dew condensation or icing allowed)
Storage : -20 to +70 ℃ -4 to +158 ℉
Ambient Humidity35 to 85 % RH, Storage: 35 to 85 % RH
Ambient IlluminanceIncandescent light: 3,500 lx or less at the light-receiving face
Vibration Resistance10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
Shock Resistance500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each
Emitting ElementInfrared LED (modulated)
Emitting Element: Peak Emission Wavelength880 nm 0.035 mil
MaterialEnclosure: Polycarbonate (glass fiber reinforced)
Cable0.057 mm2 two parallel single core wires shielded cable, 3 m 9.843 ft long
Cable ExtensionExtension up to total 5 m 16.404 ft is possible with an equivalent cable.
Weight (Typ.)24 g approx.
AccessorySensor head mounting screw: 1 sets
RemarkWhere measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 ℃ +73.4 ℉.