Item | Performance characteristics |
---|---|
Regulatory Compliance and Certification | CE Marking (EMC Directive, RoHS Directive), FDA Regulations, UL/c-UL Certification |
Measurement Center Distance | 200 mm 7.874 in |
Measuring Range | ±80 mm 3.150 in |
Repeatability | 200 μm 7.874 mil |
Linearity | ±0.2 % F.S. |
Temperature Characteristics | 0.03%F.S./℃ |
Light Source | Red semiconductor laser Class 2 [IEC / JIS / GB / FDA (Note)] Max. output: 1 mW, emission peak wavelength: 655 nm 0.026 mil (Note:)This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated June 24, 2007, issued by the FDA (Food and Drug Administration). |
Beam Diameter | ø300 μm 11.811 mil approx. |
Supply Voltage | 24 V DC ±10 % Ripple P-P 10 % |
Current Consumption | 40 mA or less (at 24 V DC supply voltage) |
Communication Output (C/Q): IO-Link Communication | IO-Link Specification V1.1 |
Communication Output (C/Q): Baud Rate | COM3 (230.4 kbps) |
Communication Output (C/Q): Process Data | 4 byte |
Communication Output (C/Q) : Minimum Cycle Time | 1.0 ms |
Control Output | PNP open-collector transistor • Maximum source current: 50 mA • Applied voltage: 30 V DC or less (Between control output to +V) • Residual voltage: 1.5 V or less (at 50 mA source current) • Leakage current: 0.1 mA or less |
Control Output: Output Operation | Switchable between either Light-ON or Dark-ON |
Control Output: Short-Circuit Protection | Incorporated (auto reset type) |
Response Time | Switchable between 1.5 ms / 5 ms / 10 ms |
Pollution Degree | 2 |
Operating Altitude | 2,000 m 6561.680 ft or less |
Protection | IP67(IEC) |
Ambient Temperature | -10 to +45℃ -14 to 113℉ (No dew condensation or icing allowed), Storage: -20 to +60℃ -4 to 140℉ |
Ambient Humidity | 35 to 85 % RH, Storage: 35 to 85 % RH |
Ambient Illuminance | Incandescent light: 3,000 ℓx or less at the light-receiving face |
Vibration Resistance | 10 to 55 Hz (period: 1 min.) frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each |
Shock Resistance | 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each |
Cable | Discrete wire type: 0.2 mm2 4-core PVC cable, 2 m 6.562 ft long M12 connector type: 0.2 mm2 4-core PVC cable with connector, 0.3 m 0.984 ft long |
Cable Extension | Extension up to total 20 m 65.617 ft is possible with 0.3 mm2, or more, cable. |
Material | Enclosure: Aluminum die-cast, Front cover: Acrylic |
Weight (Typ.) | 30 g approx. (without cable), 50 g approx. (including cable) |
Remark | (Note):Supply voltage: 24 V DC, ambient temperature: +20℃ +68℉, response time: 10 ms, and analog output value of measurement center distance are used for unspecified measurement conditions. The subject is white ceramics. |
The service is owned, operated, controlled and managed by Panasonic's distributors.
For pricing, delivery and technical questions related to this service, please direct to them.
Panasonic assumes no responsibility for any dealings you may have with distributors.