Item | Performance characteristics |
---|---|
Applicable Standards: International Standard | ISO 13849-1 (Category 4, PLe), IEC 61508-1 to 7 (SIL3), IEC 62061 (SIL3), IEC 60947-5-3, ISO 14119 |
Applicable Standards: Japan | JIS B 9705-1, JIS C 0508 1 to 7, JIS B 9961, JIS C 8201-5-2, JIS B 9710 |
Applicable Standards: Europe (EU) | EN ISO 13849-1 (Category 4, PLe), EN ISO 14119, EN 60947-5-3, EN 300 330, EN IEC 63000, EN 301 489-1 |
Directive Compliance | CE Marking (Machinery Directive, RE Directive, RoHS Directive), TÜV SÜD certification, TÜV SÜD NRTL certification (U.S.A., Canada), the U.S.'s radio regulations (FCC), Canada's radio regulations (ICES-003, RSS-310), Singapore's radio regulations (IMDA) |
Operating distance : Front / Side | Sao (OFF→ON): 5 mm 0.197 in, Sar (ON → OFF): 15 mm 0.591 in |
Power Voltage | 24V DC+10-20% Ripple P-P 10 % or less |
Current Consumption | 30 mA or less |
Control Outputs (OSSD 1, OSSD 2) | NPN open-collector transistor 2 outputs • Maximum sink current: 100 mA • Applied voltage: Same as the power supply voltage (NPN output: between control output and +V) • Residual voltage: 2 V or less (source current and sink current: 100 mA) (excluding voltage drop due to cable) • Leakage current: 0.2 mA or less (including power OFF state) • Maximum load capacity: 0.47 μF • Load wiring resistance: 3 Ω or less |
Control Outputs (OSSD 1, OSSD 2): Operation Mode | • When the actuator is detected (safe state): ON • When the actuator is not detected (unsafe state or lockout state): OFF • When the switch body (sub) does not detect actuator (series connection): OFF |
Control Output (OSSD): Protection Circuit | Incorporated |
Response Time | • For single unit: ON→OFF 100 ms or less, OFF→ON 100 ms or less • For multiple units: Time for single unit + 5 ms x (number of connected units - 1) |
Check input and output | Dedicated communication line between the switch body (standard) and the switch body (sub) (Note) * It is not for external input and output. (voltage range 0 V to 5 V DC) (Note) : When using the device as a single unit, connect the check input with the check output. |
Number of units connected in series | 30 units or less (standard 1 unit, sub 29 units) |
Pollution Degree | 3 |
Environmental Resistance: Degree of Protection | IP65(IEC) |
Ambient Temperature | -10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: -25 to +65 ℃ -13 to +149 ℉ |
Ambient Humidity | 30 to 85 % RH, storage: 30 to 95 % RH |
Environmental Resistance: Dielectric Strength Voltage | 1,000 V AC for one minute between all supply terminals connected together and enclosure |
Insulation Resistance | 20 MΩ or more, with 500 V DC megger between all supply terminals connected together and enclosure |
Vibration Resistance | 10 to 55Hz, 1 mm double amplitude, 2 hours each in X, Y, and Z directions |
Shock Resistance | 300 m/s2 (approx. 30 G), 3 times each in X, Y, and Z direction |
Material | Switch body: PBT, PC, SUS (stainless steel), EPDM Actuator: PBT, PC |
Cable | 6–core cabtyre cable, 5 m 16.404 ft long |
Connected cable length | • When using only one unit: Maximum cable length of 20 m 65.617 ft between switch body and power supply unit • When connecting multiple units in series: Maximum total cable length of 100 m 328.084 ft, maximum cable length of 20 m 65.617 ft between two adjacent units |
Weight (Typ.) | Switch body (standard): 180 g approx., Actuator : 20 g approx. |
Gross weight | 270 g approx. |
Remark | Where measurement conditions have not been specified precisely, the conditions used were ambient temperature +23 ℃ +73 ℉. ■Transponder specifications Operating frequency: 125 kHz Max. transmitter output: 3.33 μW |
Applicable Standards: North America | CAN/CSA C22.2 No.14, UL508 |