Item | Performance characteristics |
---|---|
CE Marking Directive Compliance | Machinery Directive, EMC Directive, RoHS Directive |
Applicable Standards: International Standard | ISO 13849-1 (Category 4, PLe), IEC 60947-5-2, IEC 61508-1 to 7 (SIL3), IEC 62061 (SIL3) |
Applicable Standards: Japan | JIS B 9705-1 (Category 4), JIS C 0508-1 to 7 (SIL3) |
Applicable Standards: Europe (EU) | EN 60947-5-2, EN 55011 Class A, EN 61000-6-2, EN 50178, EN ISO 13849-1 (Category 4, PLe), EN 61508-1 to 7 (SIL3) (Note) Regarding EU Machinery Directive, a Notified Body, TUV SUD, has certified with the type examination certificate. |
Applicable Standards: South Korea | S1-G-1-2009, S2-W-5-2009 |
Applicable Standards: SEMI | Conforming to SEMI-S2-0310a |
Power Voltage | 24 V DC+10-15 % Ripple P-P 10 % or less |
Current Consumption | 200 mA or less |
Control Outputs (OSSD 1, OSSD 2) | PNP open-collector transistor / NPN open-collector transistor (switch method) [Selecting PNP output] - Maximum source current: 200 mA - Applied voltage: Same as power voltage (between control output to +V) - Residual voltage: 2.5 V or less (at 200 mA source current) [Selecting NPN output] - Maximum sink current: 200 mA - Applied voltage: Same as power voltage (between control output to 0 V) - Residual voltage: 2.0 V or less (at 200 mA sink current) |
Control Outputs (OSSD 1, OSSD 2): Operation Mode | ON when normal condition or initial detection, OFF when detection leakage or wrong installation |
Control Output (OSSD 1, OSSD 2): Response Time | 20 ms or less (excluding the response time of the sensor) |
Sensor Monitor Output (AUX 1, 2, 3, 4, Non-Safety Output) | PNP open-collector transistor / NPN open-collector transistor (switch method) [Selecting PNP output] - Maximum source current: 60 mA - Applied voltage: Same as power voltage(between sensor monitor output to +V) - Residual voltage: 2.5 V or less (at 60 mA source current) [Selecting NPN output] - Maximum sink current: 60 m A - Applied voltage: Same as power voltage(between sensor monitor output to 0 V) - Residual voltage: 2.0 V or less (at 60 mA sink current) |
Sensor Monitor Output (AUX 1, 2, 3, 4, Non-Safety Output): Operation Mode (Output Operation) | ON when normal condition, OFF when initial detection or accidental leakage |
Sensor Monitor Output (AUX 1, 2, 3, 4, Non-Safety Output): Response Time | 100 ms or less (excluding the response time of the sensor) |
Lockout Output | OFF for lockout (Rating: Same as sensor monitor output) |
Protection | IP20 (IEC) (However, it should be in IP54 protection structure of control panel) |
Function | Interlock / lockout cancel / Test input / External device monitor / Safety input / Control output polarity selection / Non-safety output polarity selection / Sensor connection number setting |
Auxiliary Output | Negative logic output of control output 1 / 2 (OSSD 1 / 2) (Rating: Same as sensor monitor output) [Auxiliary output ON when control output 1 / 2 (OSSD 1/2) is OFF] |
Ambient Temperature | -10 to +55 ℃ +14 to +131℉ (No dew condensation or icing allowed), Storage: -20 to +70 ℃ -4 to +158 ℉ |
Ambient Humidity | 35 to 85 % RH, Storage: 35 to 85 % RH |
PFH<sub>D</sub> | 2.55 x 10-9 (when connecting 4 safety liquid connecting sensors) |
MTTF<sub>D</sub> | 100 years or more |
Material | Main unit case: PC + ABS (alloy) |
Weight (Typ.) | Net weight: 170 g approx Gross weight: 440 g approx |