Item | Performance characteristics |
---|---|
CE Marking Compliant Directives | EMC Directive, RoHS Directive |
Effective Charge Removal Width | 480 mm 18.898 in approx. |
Charge Removal Time | 1 sec. or less (Note: Typical value in condition of discharge distance 100 mm 3.937 in, center of the product, discharge frequency 30 Hz and no air supply.) |
Ion Balance | ±30 V or less (Note 1:Typical value in condition of discharge distance 100 mm 3.937 in, center of the product, discharge frequency 30 Hz and no air supply.) (Note 2: Ion balance refers to the average value of plus and minus. The specification value is the typical one in condition used when ambient temperature change is less than ±10 ℃, ion balance is set after 30 minutes from the discharge start, the ion balance control function is set ON.) |
Discharge Method | Pulse AC method |
Discharge Frequency | 30 Hz (Note: Set the discharge frequency to 30 Hz. Do not use any other frequency.) |
Discharge Output Voltage | ±7,000 V approx. |
Ozone Generation | 0.01 ppm or less (Note:Typical value in condition of discharge distance 100 mm 3.937 in, center of the product, discharge frequency 30 Hz and no air supply.) |
Maximum Air Pressure | 0.1 MPa |
Applicable Fluid | Air (dried clean air) (Note:The dried clean air is the air dried (dew point : equivalent of -20 ℃ -4 ℉) and filtered (mesh-size : equivalent of 0.01 μm).) |
Operating Altitude | 2,000 m 6561.68 ft or less (Note:Do not use or store in an environment that has been pressurized to an air pressure higher than the atmospheric pressure at 0 m.) |
Ambient Temperature | Head : -60 to +200 ℃ -76 to +392 ℉ (No dew condensation or icing)(Note), Storage : -10 to +65 ℃ +14 to +149 ℉ High voltage unit : 0 to +50 ℃ +32 to +122 ℉ (No dew condensation), Storage : -10 to +65 ℃ +14 to +149 ℉ (Note): Discoloration of the head may occur when used under high temperatures, but it does not affect the charge removal performance. |
Ambient Humidity | 35 to 65 % RH, Storage : 35 to 85 % RH |
Vibration Resistance | 10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each |
Shock Resistance | 100 m/s2 acceleration (10 G approx.), in X, Y and Z directions three times each |
Enclosure Earthing | Floating |
Material | Main unit enclosure : PPS, Stainless steal (SUS), Head mounting bracket : Stainless steal (SUS), Discharge needle : PC, PPS, Tungsten, Main unit enclosure of high-voltage unit : ABS |
Weight (Typ.) | Net weight : 760 g approx. |
Length of High-Voltage Cable | Heat-resistant shielded cable, 1.8 m 5.906 ft |
Accessories | ø6 ø0.236-4 Air tube joint : 1 pc., Seal cap : 1 pc., Head mounting bracket (mounted at the factory) |