Part Number List

Results 16
Models table for series TH Series Relays
Part No.DatasheetProtective ConstructionTerminal TypeCoil Resistance (at 20oC)Contact ArrangementContact TypeOperating Function Rated Coil VoltageOperate (Set) Voltage (at20&deg;C) (Initial) Release (Reset) voltage (at20&deg;C) (Initial)Rated Operating Current [&plusmn;10%] (at 20&deg;C)Coil Resistance (At 20oC)Rated Operating Power Usable Voltage RangeHeat Resistance of TypesContact Resistance (Initial)Contact MaterialNominal Switching Capacity (Resistive Load) Contact Data: Max. Carrying CurrentMin. Switching Load (Resistive) Insulation Resistance (Min. M&Omega;)(Initial)Dielectric Strength (Between Open Contacts) (Initial)Dielectric Strength (Between Contacts and Coil) (Initial)Operate (Set) Time<br>(At Rated Coil Voltage) (At 20oC) (Initial)Release (Reset) Time<br>(at Rated Coil Voltage) (at 20&deg;C) (Initial)Shock Resistance: DestructiveShock Resistance: Functional Vibration Resistance: FunctionalVibration Resistance: DestructiveExpected Life: Mechanical LifeExpected Life: ElectricalConditionsWeight (Typ.)Packing QuantityInner Carton (Pieces)Outer Carton (Pieces)
Flux tight
Surface-mount type
220Ω
1 Form C
Standard type (Ag alloy / Cu clad)
Single side stable
12V DC
Max. 7.7V DC
Min. 0.6V DC
54.5 mA
220Ω
655 mW
10 to 16V DC
Reflow type
Max. 50mΩ (N.O. side: typ. 4.5mΩ, N.C. side: typ. 5.5mΩ) (By voltage drop 1A 6V DC)
Ag alloy
N.O. side: 20A 14V DC, N.C. side: 10A 14V DC
25A/ 10 min (Coil applied voltage 12V DC, at 20°C)
1A 14V DC (at 20°C)
Min. 100 MΩ (at 500V DC, Measurement at same location as [Dielectric strength] section.)
500 Vrms for 1 min (Detection current: 10mA)
500 Vrms for 1 min (Detection current: 10mA)
Max. 10ms (without contact bounce time)
Max. 10ms (without contact bounce time) (without protective element)
Min. 1,000 m/s2
(Half-wave pulse of sine wave: 6ms, number of shocks for each direction: X, Y and Z direction: 3 times)
Min. 100 m/s2 (Half-wave pulse of sine wave: 11ms; detection time: 10µs)
10 to 100 Hz, Min. 44.1 m/s2 (Detection time: 10µs)
10 to 500 Hz, Min. 44.1 m/s2
Time of vibration for each direction; X, Y direction: 2 hours, Z direction: 4 hours
Min. 107 (at 120 times/min)
[Resistive load]
Min. 105 at rated switching capacity,
Operating frequency: 1s ON, 9s OFF
[Motor load]
Min. 105 25 A 14V DC at motor lock condition,
Operating frequency: 0.5s ON, 9.5s OFF
Ambient temperature: –40 to +110°C, Humidity: 2 to 85% RH
(Avoid icing and condensation)
Approx. 3 g
Tape and reel
500
2,000
Sealed
Surface-mount type
220Ω
1 Form C
Standard type (Ag alloy / Cu clad)
Single side stable
12V DC
Max. 7.7V DC
Min. 0.6V DC
54.5 mA
220Ω
655 mW
10 to 16V DC
Reflow type
Max. 50mΩ (N.O. side: typ. 4.5mΩ, N.C. side: typ. 5.5mΩ) (By voltage drop 1A 6V DC)
Ag alloy
N.O. side: 20A 14V DC, N.C. side: 10A 14V DC
25A/ 10 min (Coil applied voltage 12V DC, at 20°C)
1A 14V DC (at 20°C)
Min. 100 MΩ (at 500V DC, Measurement at same location as [Dielectric strength] section.)
500 Vrms for 1 min (Detection current: 10mA)
500 Vrms for 1 min (Detection current: 10mA)
Max. 10ms (without contact bounce time)
Max. 10ms (without contact bounce time) (without protective element)
Min. 1,000 m/s2
(Half-wave pulse of sine wave: 6ms, number of shocks for each direction: X, Y and Z direction: 3 times)
Min. 100 m/s2 (Half-wave pulse of sine wave: 11ms; detection time: 10µs)
10 to 100 Hz, Min. 44.1 m/s2 (Detection time: 10µs)
10 to 500 Hz, Min. 44.1 m/s2
Time of vibration for each direction; X, Y direction: 2 hours, Z direction: 4 hours
Min. 107 (at 120 times/min)
[Resistive load]
Min. 105 at rated switching capacity,
Operating frequency: 1s ON, 9s OFF
[Motor load]
Min. 105 25 A 14V DC at motor lock condition,
Operating frequency: 0.5s ON, 9.5s OFF
Ambient temperature: –40 to +110°C, Humidity: 2 to 85% RH
(Avoid icing and condensation)
Approx. 3 g
Tape and reel
500
2,000
Flux tight
Surface-mount type
160Ω
1 Form C
Standard type (Ag alloy / Cu clad)
Single side stable
12V DC
Max. 6.5V DC
Min. 0.6V DC
75 mA
160Ω
900 mW
10 to 16V DC
Reflow type
Max. 50mΩ (N.O. side: typ. 4.5mΩ, N.C. side: typ. 5.5mΩ) (By voltage drop 1A 6V DC)
Ag alloy
N.O. side: 20A 14V DC, N.C. side: 10A 14V DC
25A/ 10 min (Coil applied voltage 12V DC, at 20°C)
1A 14V DC (at 20°C)
Min. 100 MΩ (at 500V DC, Measurement at same location as [Dielectric strength] section.)
500 Vrms for 1 min (Detection current: 10mA)
500 Vrms for 1 min (Detection current: 10mA)
Max. 10ms (without contact bounce time)
Max. 10ms (without contact bounce time) (without protective element)
Min. 1,000 m/s2
(Half-wave pulse of sine wave: 6ms, number of shocks for each direction: X, Y and Z direction: 3 times)
Min. 100 m/s2 (Half-wave pulse of sine wave: 11ms; detection time: 10µs)
10 to 100 Hz, Min. 44.1 m/s2 (Detection time: 10µs)
10 to 500 Hz, Min. 44.1 m/s2
Time of vibration for each direction; X, Y direction: 2 hours, Z direction: 4 hours
Min. 107 (at 120 times/min)
[Resistive load]
Min. 105 at rated switching capacity,
Operating frequency: 1s ON, 9s OFF
[Motor load]
Min. 105 25 A 14V DC at motor lock condition,
Operating frequency: 0.5s ON, 9.5s OFF
Ambient temperature: –40 to +110°C, Humidity: 2 to 85% RH
(Avoid icing and condensation)
Approx. 3 g
Tape and reel
500
2,000
Flux tight
Surface-mount type
220Ω
1 Form C x 2 (10 pins)
Standard type
Single side stable
12V DC
Max. 7.7V DC
Min. 0.6V DC
54.5 mA
220Ω
655 mW
10 to 16V DC
Reflow type
Max. 50mΩ (N.O. side: typ. 4.5mΩ, N.C. side: typ. 5.5mΩ) (By voltage drop 1A 6V DC)
Ag alloy
N.O. side: 20A 14V DC, N.C. side: 10A 14V DC
25A/ 10 min (Coil applied voltage 12V DC, at 20°C)
1A 14V DC (at 20°C)
Min. 100 MΩ (at 500V DC, Measurement at same location as [Dielectric strength] section.)
500 Vrms for 1 min (Detection current: 10mA)
500 Vrms for 1 min (Detection current: 10mA)
Max. 10ms (without contact bounce time)
Max. 10ms (without contact bounce time) (without protective element)
Min. 1,000 m/s2
(Half-wave pulse of sine wave: 6ms, number of shocks for each direction: X, Y and Z direction: 3 times)
Min. 100 m/s2 (Half-wave pulse of sine wave: 11ms; detection time: 10µs)
10 to 100 Hz, Min. 44.1 m/s2 (Detection time: 10µs)
10 to 500 Hz, Min. 44.1 m/s2
Time of vibration for each direction; X, Y direction: 2 hours, Z direction: 4 hours
Min. 107 (at 120 times/min)
[Resistive load]
Min. 105 at rated switching capacity,
Operating frequency: 1s ON, 9s OFF
[Motor load]
Min. 105 25 A 14V DC at motor lock condition,
Operating frequency: 0.5s ON, 9.5s OFF
Ambient temperature: –40 to +110°C, Humidity: 2 to 85% RH
(Avoid icing and condensation)
Approx. 6 g
Tape and reel
400
2,000
Sealed
Surface-mount type
160Ω
1 Form C
Standard type (Ag alloy / Cu clad)
Single side stable
12V DC
Max. 6.5V DC
Min. 0.6V DC
75 mA
160Ω
900 mW
10 to 16V DC
Reflow type
Max. 50mΩ (N.O. side: typ. 4.5mΩ, N.C. side: typ. 5.5mΩ) (By voltage drop 1A 6V DC)
Ag alloy
N.O. side: 20A 14V DC, N.C. side: 10A 14V DC
25A/ 10 min (Coil applied voltage 12V DC, at 20°C)
1A 14V DC (at 20°C)
Min. 100 MΩ (at 500V DC, Measurement at same location as [Dielectric strength] section.)
500 Vrms for 1 min (Detection current: 10mA)
500 Vrms for 1 min (Detection current: 10mA)
Max. 10ms (without contact bounce time)
Max. 10ms (without contact bounce time) (without protective element)
Min. 1,000 m/s2
(Half-wave pulse of sine wave: 6ms, number of shocks for each direction: X, Y and Z direction: 3 times)
Min. 100 m/s2 (Half-wave pulse of sine wave: 11ms; detection time: 10µs)
10 to 100 Hz, Min. 44.1 m/s2 (Detection time: 10µs)
10 to 500 Hz, Min. 44.1 m/s2
Time of vibration for each direction; X, Y direction: 2 hours, Z direction: 4 hours
Min. 107 (at 120 times/min)
[Resistive load]
Min. 105 at rated switching capacity,
Operating frequency: 1s ON, 9s OFF
[Motor load]
Min. 105 25 A 14V DC at motor lock condition,
Operating frequency: 0.5s ON, 9.5s OFF
Ambient temperature: –40 to +110°C, Humidity: 2 to 85% RH
(Avoid icing and condensation)
Approx. 3 g
Tape and reel
500
2,000
Sealed
Surface-mount type
220Ω
1 Form C
Standard type
Single side stable
12V DC
Max. 7.7V DC
Min. 0.6V DC
54.5 mA
220Ω
655 mW
10 to 16V DC
Reflow type
Max. 50mΩ (N.O. side: typ. 4.5mΩ, N.C. side: typ. 5.5mΩ) (By voltage drop 1A 6V DC)
Ag alloy
N.O. side: 20A 14V DC, N.C. side: 10A 14V DC
25A/ 10 min (Coil applied voltage 12V DC, at 20°C)
1A 14V DC (at 20°C)
Min. 100 MΩ (at 500V DC, Measurement at same location as [Dielectric strength] section.)
500 Vrms for 1 min (Detection current: 10mA)
500 Vrms for 1 min (Detection current: 10mA)
Max. 10ms (without contact bounce time)
Max. 10ms (without contact bounce time) (without protective element)
Min. 1,000 m/s2
(Half-wave pulse of sine wave: 6ms, number of shocks for each direction: X, Y and Z direction: 3 times)
Min. 100 m/s2 (Half-wave pulse of sine wave: 11ms; detection time: 10µs)
10 to 100 Hz, Min. 44.1 m/s2 (Detection time: 10µs)
10 to 500 Hz, Min. 44.1 m/s2
Time of vibration for each direction; X, Y direction: 2 hours, Z direction: 4 hours
Min. 107 (at 120 times/min)
[Resistive load]
Min. 105 at rated switching capacity,
Operating frequency: 1s ON, 9s OFF
[Motor load]
Min. 105 25 A 14V DC at motor lock condition,
Operating frequency: 0.5s ON, 9.5s OFF
Ambient temperature: –40 to +110°C, Humidity: 2 to 85% RH
(Avoid icing and condensation)
Approx. 3 g
Tape and reel
500
2,000
Flux tight
Surface-mount type
160Ω
1 Form C
Standard type
Single side stable
12V DC
Max. 6.5V DC
Min. 0.6V DC
75 mA
160Ω
900 mW
10 to 16V DC
Reflow type
Max. 50mΩ (N.O. side: typ. 4.5mΩ, N.C. side: typ. 5.5mΩ) (By voltage drop 1A 6V DC)
Ag alloy
N.O. side: 20A 14V DC, N.C. side: 10A 14V DC
25A/ 10 min (Coil applied voltage 12V DC, at 20°C)
1A 14V DC (at 20°C)
Min. 100 MΩ (at 500V DC, Measurement at same location as [Dielectric strength] section.)
500 Vrms for 1 min (Detection current: 10mA)
500 Vrms for 1 min (Detection current: 10mA)
Max. 10ms (without contact bounce time)
Max. 10ms (without contact bounce time) (without protective element)
Min. 1,000 m/s2
(Half-wave pulse of sine wave: 6ms, number of shocks for each direction: X, Y and Z direction: 3 times)
Min. 100 m/s2 (Half-wave pulse of sine wave: 11ms; detection time: 10µs)
10 to 100 Hz, Min. 44.1 m/s2 (Detection time: 10µs)
10 to 500 Hz, Min. 44.1 m/s2
Time of vibration for each direction; X, Y direction: 2 hours, Z direction: 4 hours
Min. 107 (at 120 times/min)
[Resistive load]
Min. 105 at rated switching capacity,
Operating frequency: 1s ON, 9s OFF
[Motor load]
Min. 105 25 A 14V DC at motor lock condition,
Operating frequency: 0.5s ON, 9.5s OFF
Ambient temperature: –40 to +110°C, Humidity: 2 to 85% RH
(Avoid icing and condensation)
Approx. 3 g
Tape and reel
500
2,000
Sealed
Surface-mount type
220Ω
1 Form C x 2 (10 pins)
Standard type
Single side stable
12V DC
Max. 7.7V DC
Min. 0.6V DC
54.5 mA
220Ω
655 mW
10 to 16V DC
Reflow type
Max. 50mΩ (N.O. side: typ. 4.5mΩ, N.C. side: typ. 5.5mΩ) (By voltage drop 1A 6V DC)
Ag alloy
N.O. side: 20A 14V DC, N.C. side: 10A 14V DC
25A/ 10 min (Coil applied voltage 12V DC, at 20°C)
1A 14V DC (at 20°C)
Min. 100 MΩ (at 500V DC, Measurement at same location as [Dielectric strength] section.)
500 Vrms for 1 min (Detection current: 10mA)
500 Vrms for 1 min (Detection current: 10mA)
Max. 10ms (without contact bounce time)
Max. 10ms (without contact bounce time) (without protective element)
Min. 1,000 m/s2
(Half-wave pulse of sine wave: 6ms, number of shocks for each direction: X, Y and Z direction: 3 times)
Min. 100 m/s2 (Half-wave pulse of sine wave: 11ms; detection time: 10µs)
10 to 100 Hz, Min. 44.1 m/s2 (Detection time: 10µs)
10 to 500 Hz, Min. 44.1 m/s2
Time of vibration for each direction; X, Y direction: 2 hours, Z direction: 4 hours
Min. 107 (at 120 times/min)
[Resistive load]
Min. 105 at rated switching capacity,
Operating frequency: 1s ON, 9s OFF
[Motor load]
Min. 105 25 A 14V DC at motor lock condition,
Operating frequency: 0.5s ON, 9.5s OFF
Ambient temperature: –40 to +110°C, Humidity: 2 to 85% RH
(Avoid icing and condensation)
Approx. 6 g
Tape and reel
400
2,000
Flux tight
Surface-mount type
220Ω
1 Form C
Standard type
Single side stable
12V DC
Max. 7.7V DC
Min. 0.6V DC
54.5 mA
220Ω
655 mW
10 to 16V DC
Reflow type
Max. 50mΩ (N.O. side: typ. 4.5mΩ, N.C. side: typ. 5.5mΩ) (By voltage drop 1A 6V DC)
Ag alloy
N.O. side: 20A 14V DC, N.C. side: 10A 14V DC
25A/ 10 min (Coil applied voltage 12V DC, at 20°C)
1A 14V DC (at 20°C)
Min. 100 MΩ (at 500V DC, Measurement at same location as [Dielectric strength] section.)
500 Vrms for 1 min (Detection current: 10mA)
500 Vrms for 1 min (Detection current: 10mA)
Max. 10ms (without contact bounce time)
Max. 10ms (without contact bounce time) (without protective element)
Min. 1,000 m/s2
(Half-wave pulse of sine wave: 6ms, number of shocks for each direction: X, Y and Z direction: 3 times)
Min. 100 m/s2 (Half-wave pulse of sine wave: 11ms; detection time: 10µs)
10 to 100 Hz, Min. 44.1 m/s2 (Detection time: 10µs)
10 to 500 Hz, Min. 44.1 m/s2
Time of vibration for each direction; X, Y direction: 2 hours, Z direction: 4 hours
Min. 107 (at 120 times/min)
[Resistive load]
Min. 105 at rated switching capacity,
Operating frequency: 1s ON, 9s OFF
[Motor load]
Min. 105 25 A 14V DC at motor lock condition,
Operating frequency: 0.5s ON, 9.5s OFF
Ambient temperature: –40 to +110°C, Humidity: 2 to 85% RH
(Avoid icing and condensation)
Approx. 3 g
Tape and reel
500
2,000
Sealed
Surface-mount type
160Ω
1 Form C
Standard type
Single side stable
12V DC
Max. 6.5V DC
Min. 0.6V DC
75 mA
160Ω
900 mW
10 to 16V DC
Reflow type
Max. 50mΩ (N.O. side: typ. 4.5mΩ, N.C. side: typ. 5.5mΩ) (By voltage drop 1A 6V DC)
Ag alloy
N.O. side: 20A 14V DC, N.C. side: 10A 14V DC
25A/ 10 min (Coil applied voltage 12V DC, at 20°C)
1A 14V DC (at 20°C)
Min. 100 MΩ (at 500V DC, Measurement at same location as [Dielectric strength] section.)
500 Vrms for 1 min (Detection current: 10mA)
500 Vrms for 1 min (Detection current: 10mA)
Max. 10ms (without contact bounce time)
Max. 10ms (without contact bounce time) (without protective element)
Min. 1,000 m/s2
(Half-wave pulse of sine wave: 6ms, number of shocks for each direction: X, Y and Z direction: 3 times)
Min. 100 m/s2 (Half-wave pulse of sine wave: 11ms; detection time: 10µs)
10 to 100 Hz, Min. 44.1 m/s2 (Detection time: 10µs)
10 to 500 Hz, Min. 44.1 m/s2
Time of vibration for each direction; X, Y direction: 2 hours, Z direction: 4 hours
Min. 107 (at 120 times/min)
[Resistive load]
Min. 105 at rated switching capacity,
Operating frequency: 1s ON, 9s OFF
[Motor load]
Min. 105 25 A 14V DC at motor lock condition,
Operating frequency: 0.5s ON, 9.5s OFF
Ambient temperature: –40 to +110°C, Humidity: 2 to 85% RH
(Avoid icing and condensation)
Approx. 3 g
Tape and reel
500
2,000

What's New

Stay up to date