Specifications
Item | Performance characteristics |
---|---|
Protective Construction | Sealed |
Terminal Type | Surface-mount type |
Coil Resistance (at 20oC) | 220Ω |
Contact Arrangement | 1 Form C |
Contact Type | Standard type (Ag alloy / Cu clad) |
Operating Function | Single side stable |
Rated Coil Voltage | 12V DC |
Operate (Set) Voltage (at20°C) (Initial) | Max. 7.7V DC |
Release (Reset) voltage (at20°C) (Initial) | Min. 0.6V DC |
Rated Operating Current [±10%] (at 20°C) | 54.5 mA |
Coil Resistance (At 20oC) | 220Ω |
Rated Operating Power | 655 mW |
Usable Voltage Range | 10 to 16V DC |
Heat Resistance of Types | Reflow type |
Contact Resistance (Initial) | Max. 50mΩ (N.O. side: typ. 4.5mΩ, N.C. side: typ. 5.5mΩ) (By voltage drop 1A 6V DC) |
Contact Material | Ag alloy |
Nominal Switching Capacity (Resistive Load) | N.O. side: 20A 14V DC, N.C. side: 10A 14V DC |
Contact Data: Max. Carrying Current | 25A/ 10 min (Coil applied voltage 12V DC, at 20°C) |
Min. Switching Load (Resistive) | 1A 14V DC (at 20°C) |
Insulation Resistance (Min. MΩ)(Initial) | Min. 100 MΩ (at 500V DC, Measurement at same location as [Dielectric strength] section.) |
Dielectric Strength (Between Open Contacts) (Initial) | 500 Vrms for 1 min (Detection current: 10mA) |
Dielectric Strength (Between Contacts and Coil) (Initial) | 500 Vrms for 1 min (Detection current: 10mA) |
Operate (Set) Time<br>(At Rated Coil Voltage) (At 20oC) (Initial) | Max. 10ms (without contact bounce time) |
Release (Reset) Time<br>(at Rated Coil Voltage) (at 20°C) (Initial) | Max. 10ms (without contact bounce time) (without protective element) |
Shock Resistance: Destructive | Min. 1,000 m/s2 (Half-wave pulse of sine wave: 6ms, number of shocks for each direction: X, Y and Z direction: 3 times) |
Shock Resistance: Functional | Min. 100 m/s2 (Half-wave pulse of sine wave: 11ms; detection time: 10µs) |
Vibration Resistance: Functional | 10 to 100 Hz, Min. 44.1 m/s2 (Detection time: 10µs) |
Vibration Resistance: Destructive | 10 to 500 Hz, Min. 44.1 m/s2 Time of vibration for each direction; X, Y direction: 2 hours, Z direction: 4 hours |
Expected Life: Mechanical Life | Min. 107 (at 120 times/min) |
Expected Life: Electrical | [Resistive load] Min. 105 at rated switching capacity, Operating frequency: 1s ON, 9s OFF [Motor load] Min. 105 25 A 14V DC at motor lock condition, Operating frequency: 0.5s ON, 9.5s OFF |
Conditions | Ambient temperature: –40 to +110°C, Humidity: 2 to 85% RH (Avoid icing and condensation) |
Weight (Typ.) | Approx. 3 g |
Packing Quantity | Tape and reel |
Inner Carton (Pieces) | 500 |
Outer Carton (Pieces) | 2,000 |
Stock check
ACTH5CB3