| | 2.5mm | 6 V DC | 1 Form A | 48 A (AC, DC) | Flux-resistant | Single side stable | PC board terminal (blade) | 48 A | 25 | Max. 70% V of rated coil voltage (Initial) | 100 | Min. 10% V of rated coil voltage (Initial) | 320 mA | 18.8 Ω | 1,920 mW | 110% V of rated coil voltage | Single | Max. 100 mΩ (by voltage drop 6 V DC 1 A) | AgNi type | 48 A 490 V AC, 48 A 48 V DC | 23,520 VA (AC), 2,304 W (DC) | 490 V AC, 48 V DC | 100 mA 5 V DC | Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) | 5,000 Vrms for 1 min (detection current: 10 mA) | 2,000 Vrms for 1 min (detection current: 10 mA) | 10,000 V | 40 to 100% V (at -50~55°C) 50 to 60% V (at 55~85°C) | Max. 30 ms at rated coil voltage (without bounce) | 98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) | Max. 10 ms at rated coil voltage (without bounce, without diode) | 980 m/s2 (half-sine shock pulse: 6 ms) | 10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 1.5 mm) | Min. 10x106 ope. (switching frequency: at 180 times/min) | Ambient temperature: -50 to +85°C (When using at 55°C or higher, the coil holding voltage should be 50% V to 60% V) Humidity: 5 to 85% RH (Avoid icing and condensation) | Approx. 80 g | [at 85°C, switching frequency ON : OFF = 1 s : 9 s] Min. 30x103 ope. 48 A 277 V AC Min. 30x103 ope. 48 A 30 V DC
[room temperature, switching frequency ON : OFF = 1 s : 9 s] Min. 10x103 ope. 48 A 490 V AC Min. 10x103 ope. 48 A 48 V DC | Carton | [at 85°C, switching frequency ON : OFF = 0.1 s : 10 s] Min. 30x103 ope. 48 A 250 V AC (cosΦ = 0.8) Min. 50 ope. 72 A 250 V AC (cosΦ = 0.8) |
| | 3.0mm | 24 V DC | 1 Form A | 60 A (AC), 90 A (DC) | Flux-resistant | Single side stable | PC board terminal (wide blade) | 90 A | 25 | Max. 70% V of rated coil voltage (Initial) | 100 | Min. 10% V of rated coil voltage (Initial) | 80 mA | 300 Ω | 1,920 mW | 110% V of rated coil voltage | Single | Max. 10 mΩ (by voltage drop 5 V DC 20 A) | AgNi type | 60 A 490 V AC, 90 A 60 V DC | 29,400 VA (AC), 5,400 W (DC) | 490 V AC, 60 V DC | 100 mA 5 V DC | Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) | 5,000 Vrms for 1 min (detection current: 10 mA) | 2,000 Vrms for 1 min (detection current: 10 mA) | 10,000 V | 40 to 100% V (at -50~55°C) 50 to 60% V (at 55~85°C) | Max. 30 ms at rated coil voltage (without bounce) | 98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) | Max. 10 ms at rated coil voltage (without bounce, without diode) | 980 m/s2 (half-sine shock pulse: 6 ms) | 10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 1.5 mm) | Min. 106 ope. (switching frequency: at 180 times/min) | Ambient temperature: -50 to +85°C (When using at 55°C or higher, the coil holding voltage should be 50% V to 60% V) Humidity: 5 to 85% RH (Avoid icing and condensation) | Approx. 85 g | [at 85°C, switching frequency ON : OFF = 1 s : 9 s] Min. 10x103 ope. 60 A 277 V AC Min. 103 ope. 90 A 277 V AC Min. 103 ope. 90 A 60 V DC
[room temperature, switching frequency ON : OFF = 1 s : 9 s] Min. 10x103 ope. 60 A 490 V AC Min. 10x103 ope. 80 A 277 V AC Min. 10x103 ope. 80 A 48 V DC | Carton | |
| | 2.5mm | 9 V DC | 1 Form A | 35 A (AC, DC) | Flux-resistant | Single side stable | PC board terminal | 35 A | 25 | Max. 70% V of rated coil voltage (Initial) | 100 | Min. 10% V of rated coil voltage (Initial) | 213 mA | 42.2 Ω | 1,920 mW | 110% V of rated coil voltage | Single | Max. 100 mΩ (by voltage drop 6 V DC 1 A) | AgSnO2 type | 35 A 490 V AC, 35 A 48 V DC | 17,150 VA (AC), 1,680 W (DC) | 490 V AC, 48 V DC | 100 mA 5 V DC | Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) | 5,000 Vrms for 1 min (detection current: 10 mA) | 2,000 Vrms for 1 min (detection current: 10 mA) | 10,000 V | 40 to 100% V (at -50~55°C) 50 to 60% V (at 55~85°C) | Max. 30 ms at rated coil voltage (without bounce) | 98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) | Max. 10 ms at rated coil voltage (without bounce, without diode) | 980 m/s2 (half-sine shock pulse: 6 ms) | 10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 1.5 mm) | Min. 10x106 ope. (switching frequency: at 180 times/min) | Ambient temperature: -50 to +85°C (When using at 55°C or higher, the coil holding voltage should be 50% V to 60% V) Humidity: 5 to 85% RH (Avoid icing and condensation) | Approx. 80 g | [room temperature, switching frequency: 20 times/min] Min. 200x103 ope. 30 A 250 V AC
[at 85°C, switching frequency ON : OFF = 1 s : 9 s] Min. 30x103 ope. 35 A 277 V AC
[room temperature, switching frequency ON : OFF = 1 s : 9 s] Min. 10x103 ope. 35 A 490 V AC Min. 10x103 ope. 35 A 48 V DC | Carton | |
| | 3.6mm | 24 V DC | 1 Form A | 55 A (AC), 90 A (DC) | Flux-resistant | Single side stable | PC board terminal (wide blade) | 90 A Wide gap | 25 | Max. 75% V of rated coil voltage (Initial) | 100 | Min. 10% V of rated coil voltage (Initial) | 80 mA | 300 Ω | 1,920 mW | 110% V of rated coil voltage | Single | Max. 10 mΩ (by voltage drop 5 V DC 20 A) | AgNi type | 55 A 800 V AC, 90 A 60 V DC | 44,000 VA (AC), 5,400 W (DC) | 800 V AC, 60 V DC | 100 mA 5 V DC | Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) | 5,000 Vrms for 1 min (detection current: 10 mA) | 2,000 Vrms for 1 min (detection current: 10 mA) | 10,000 V | 40 to 100% V (at -50~55°C) 50 to 60% V (at 55~85°C) | Max. 30 ms at rated coil voltage (without bounce) | 98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) | Max. 10 ms at rated coil voltage (without bounce, without diode) | 980 m/s2 (half-sine shock pulse: 6 ms) | 10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 1.5 mm) | Min. 106 ope. (switching frequency: at 180 times/min) | Ambient temperature: -50 to +85°C (When using at 55°C or higher, the coil holding voltage should be 50% V to 60% V) Humidity: 5 to 85% RH (Avoid icing and condensation) | Approx. 85 g | [at 85°C, switching frequency ON : OFF = 1 s : 9 s] Min. 10x103 ope. 60 A 277 V AC Min. 103 ope. 90 A 277 V AC Min. 103 ope. 90 A 60 V DC
[room temperature, switching frequency ON : OFF = 1 s : 9 s] Min. 103 ope. 55 A 800 V AC Min. 10x103 ope. 60 A 490 V AC Min. 10x103 ope. 80 A 277 V AC Min. 10x103 ope. 80 A 48 V DC | Carton | |
| | 2.5mm | 24 V DC | 1 Form A | 48 A (AC, DC) | Flux-resistant | Single side stable | PC board terminal (blade) | 48 A | 25 | Max. 70% V of rated coil voltage (Initial) | 100 | Min. 10% V of rated coil voltage (Initial) | 80 mA | 300 Ω | 1,920 mW | 110% V of rated coil voltage | Single | Max. 100 mΩ (by voltage drop 6 V DC 1 A) | AgNi type | 48 A 490 V AC, 48 A 48 V DC | 23,520 VA (AC), 2,304 W (DC) | 490 V AC, 48 V DC | 100 mA 5 V DC | Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) | 5,000 Vrms for 1 min (detection current: 10 mA) | 2,000 Vrms for 1 min (detection current: 10 mA) | 10,000 V | 40 to 100% V (at -50~55°C) 50 to 60% V (at 55~85°C) | Max. 30 ms at rated coil voltage (without bounce) | 98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) | Max. 10 ms at rated coil voltage (without bounce, without diode) | 980 m/s2 (half-sine shock pulse: 6 ms) | 10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 1.5 mm) | Min. 10x106 ope. (switching frequency: at 180 times/min) | Ambient temperature: -50 to +85°C (When using at 55°C or higher, the coil holding voltage should be 50% V to 60% V) Humidity: 5 to 85% RH (Avoid icing and condensation) | Approx. 80 g | [at 85°C, switching frequency ON : OFF = 1 s : 9 s] Min. 30x103 ope. 48 A 277 V AC Min. 30x103 ope. 48 A 30 V DC
[room temperature, switching frequency ON : OFF = 1 s : 9 s] Min. 10x103 ope. 48 A 490 V AC Min. 10x103 ope. 48 A 48 V DC | Carton | [at 85°C, switching frequency ON : OFF = 0.1 s : 10 s] Min. 30x103 ope. 48 A 250 V AC (cosΦ = 0.8) Min. 50 ope. 72 A 250 V AC (cosΦ = 0.8) |
| | 3.0mm | 6 V DC | 1 Form A | 60 A (AC), 90 A (DC) | Flux-resistant | Single side stable | PC board terminal (wide blade) | 90 A | 25 | Max. 70% V of rated coil voltage (Initial) | 100 | Min. 10% V of rated coil voltage (Initial) | 320 mA | 18.8 Ω | 1,920 mW | 110% V of rated coil voltage | Single | Max. 10 mΩ (by voltage drop 5 V DC 20 A) | AgNi type | 60 A 490 V AC, 90 A 60 V DC | 29,400 VA (AC), 5,400 W (DC) | 490 V AC, 60 V DC | 100 mA 5 V DC | Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) | 5,000 Vrms for 1 min (detection current: 10 mA) | 2,000 Vrms for 1 min (detection current: 10 mA) | 10,000 V | 40 to 100% V (at -50~55°C) 50 to 60% V (at 55~85°C) | Max. 30 ms at rated coil voltage (without bounce) | 98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) | Max. 10 ms at rated coil voltage (without bounce, without diode) | 980 m/s2 (half-sine shock pulse: 6 ms) | 10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 1.5 mm) | Min. 106 ope. (switching frequency: at 180 times/min) | Ambient temperature: -50 to +85°C (When using at 55°C or higher, the coil holding voltage should be 50% V to 60% V) Humidity: 5 to 85% RH (Avoid icing and condensation) | Approx. 85 g | [at 85°C, switching frequency ON : OFF = 1 s : 9 s] Min. 10x103 ope. 60 A 277 V AC Min. 103 ope. 90 A 277 V AC Min. 103 ope. 90 A 60 V DC
[room temperature, switching frequency ON : OFF = 1 s : 9 s] Min. 10x103 ope. 60 A 490 V AC Min. 10x103 ope. 80 A 277 V AC Min. 10x103 ope. 80 A 48 V DC | Carton | |
| | 2.5mm | 9 V DC | 1 Form A | 48 A (AC, DC) | Flux-resistant | Single side stable | PC board terminal (blade) | 48 A | 25 | Max. 70% V of rated coil voltage (Initial) | 100 | Min. 10% V of rated coil voltage (Initial) | 213 mA | 42.2 Ω | 1,920 mW | 110% V of rated coil voltage | Single | Max. 100 mΩ (by voltage drop 6 V DC 1 A) | AgNi type | 48 A 490 V AC, 48 A 48 V DC | 23,520 VA (AC), 2,304 W (DC) | 490 V AC, 48 V DC | 100 mA 5 V DC | Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) | 5,000 Vrms for 1 min (detection current: 10 mA) | 2,000 Vrms for 1 min (detection current: 10 mA) | 10,000 V | 40 to 100% V (at -50~55°C) 50 to 60% V (at 55~85°C) | Max. 30 ms at rated coil voltage (without bounce) | 98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) | Max. 10 ms at rated coil voltage (without bounce, without diode) | 980 m/s2 (half-sine shock pulse: 6 ms) | 10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 1.5 mm) | Min. 10x106 ope. (switching frequency: at 180 times/min) | Ambient temperature: -50 to +85°C (When using at 55°C or higher, the coil holding voltage should be 50% V to 60% V) Humidity: 5 to 85% RH (Avoid icing and condensation) | Approx. 80 g | [at 85°C, switching frequency ON : OFF = 1 s : 9 s] Min. 30x103 ope. 48 A 277 V AC Min. 30x103 ope. 48 A 30 V DC
[room temperature, switching frequency ON : OFF = 1 s : 9 s] Min. 10x103 ope. 48 A 490 V AC Min. 10x103 ope. 48 A 48 V DC | Carton | [at 85°C, switching frequency ON : OFF = 0.1 s : 10 s] Min. 30x103 ope. 48 A 250 V AC (cosΦ = 0.8) Min. 50 ope. 72 A 250 V AC (cosΦ = 0.8) |
| | 2.5mm | 12 V DC | 1 Form A | 35 A (AC, DC) | Flux-resistant | Single side stable | PC board terminal | 35 A | 25 | Max. 70% V of rated coil voltage (Initial) | 100 | Min. 10% V of rated coil voltage (Initial) | 160 mA | 75 Ω | 1,920 mW | 110% V of rated coil voltage | Single | Max. 100 mΩ (by voltage drop 6 V DC 1 A) | AgSnO2 type | 35 A 490 V AC, 35 A 48 V DC | 17,150 VA (AC), 1,680 W (DC) | 490 V AC, 48 V DC | 100 mA 5 V DC | Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) | 5,000 Vrms for 1 min (detection current: 10 mA) | 2,000 Vrms for 1 min (detection current: 10 mA) | 10,000 V | 40 to 100% V (at -50~55°C) 50 to 60% V (at 55~85°C) | Max. 30 ms at rated coil voltage (without bounce) | 98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) | Max. 10 ms at rated coil voltage (without bounce, without diode) | 980 m/s2 (half-sine shock pulse: 6 ms) | 10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 1.5 mm) | Min. 10x106 ope. (switching frequency: at 180 times/min) | Ambient temperature: -50 to +85°C (When using at 55°C or higher, the coil holding voltage should be 50% V to 60% V) Humidity: 5 to 85% RH (Avoid icing and condensation) | Approx. 80 g | [room temperature, switching frequency: 20 times/min] Min. 200x103 ope. 30 A 250 V AC
[at 85°C, switching frequency ON : OFF = 1 s : 9 s] Min. 30x103 ope. 35 A 277 V AC
[room temperature, switching frequency ON : OFF = 1 s : 9 s] Min. 10x103 ope. 35 A 490 V AC Min. 10x103 ope. 35 A 48 V DC | Carton | |
| | 3.0mm | 9 V DC | 1 Form A | 60 A (AC), 90 A (DC) | Flux-resistant | Single side stable | PC board terminal (wide blade) | 90 A | 25 | Max. 70% V of rated coil voltage (Initial) | 100 | Min. 10% V of rated coil voltage (Initial) | 213 mA | 42.2 Ω | 1,920 mW | 110% V of rated coil voltage | Single | Max. 10 mΩ (by voltage drop 5 V DC 20 A) | AgNi type | 60 A 490 V AC, 90 A 60 V DC | 29,400 VA (AC), 5,400 W (DC) | 490 V AC, 60 V DC | 100 mA 5 V DC | Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) | 5,000 Vrms for 1 min (detection current: 10 mA) | 2,000 Vrms for 1 min (detection current: 10 mA) | 10,000 V | 40 to 100% V (at -50~55°C) 50 to 60% V (at 55~85°C) | Max. 30 ms at rated coil voltage (without bounce) | 98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) | Max. 10 ms at rated coil voltage (without bounce, without diode) | 980 m/s2 (half-sine shock pulse: 6 ms) | 10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 1.5 mm) | Min. 106 ope. (switching frequency: at 180 times/min) | Ambient temperature: -50 to +85°C (When using at 55°C or higher, the coil holding voltage should be 50% V to 60% V) Humidity: 5 to 85% RH (Avoid icing and condensation) | Approx. 85 g | [at 85°C, switching frequency ON : OFF = 1 s : 9 s] Min. 10x103 ope. 60 A 277 V AC Min. 103 ope. 90 A 277 V AC Min. 103 ope. 90 A 60 V DC
[room temperature, switching frequency ON : OFF = 1 s : 9 s] Min. 10x103 ope. 60 A 490 V AC Min. 10x103 ope. 80 A 277 V AC Min. 10x103 ope. 80 A 48 V DC | Carton | |
| | 2.5mm | 24 V DC | 1 Form A | 35 A (AC, DC) | Flux-resistant | Single side stable | PC board terminal | 35 A | 25 | Max. 70% V of rated coil voltage (Initial) | 100 | Min. 10% V of rated coil voltage (Initial) | 80 mA | 300 Ω | 1,920 mW | 110% V of rated coil voltage | Single | Max. 100 mΩ (by voltage drop 6 V DC 1 A) | AgSnO2 type | 35 A 490 V AC, 35 A 48 V DC | 17,150 VA (AC), 1,680 W (DC) | 490 V AC, 48 V DC | 100 mA 5 V DC | Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) | 5,000 Vrms for 1 min (detection current: 10 mA) | 2,000 Vrms for 1 min (detection current: 10 mA) | 10,000 V | 40 to 100% V (at -50~55°C) 50 to 60% V (at 55~85°C) | Max. 30 ms at rated coil voltage (without bounce) | 98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) | Max. 10 ms at rated coil voltage (without bounce, without diode) | 980 m/s2 (half-sine shock pulse: 6 ms) | 10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 µs) | 10 to 55 Hz (at double amplitude of 1.5 mm) | Min. 10x106 ope. (switching frequency: at 180 times/min) | Ambient temperature: -50 to +85°C (When using at 55°C or higher, the coil holding voltage should be 50% V to 60% V) Humidity: 5 to 85% RH (Avoid icing and condensation) | Approx. 80 g | [room temperature, switching frequency: 20 times/min] Min. 200x103 ope. 30 A 250 V AC
[at 85°C, switching frequency ON : OFF = 1 s : 9 s] Min. 30x103 ope. 35 A 277 V AC
[room temperature, switching frequency ON : OFF = 1 s : 9 s] Min. 10x103 ope. 35 A 490 V AC Min. 10x103 ope. 35 A 48 V DC | Carton | |