Specifications

Specifications table for model AEV17012
ItemPerformance characteristics
Terminal TypeScrew terminal
Coil Terminal StructureLead wire
Rated Coil Voltage12V DC
Contact Capacity200 A
Protective ConstructionCapsule contact
Operating Function Single side stable
Operate (Set) Voltage (at20°C) (Initial) Max. 9 V DC
Release (Reset) voltage (at20℃) (Initial)Min. 1 V DC
Rated Operating Current [±10%] (at 20°C)0.5 A
Coil Resistance (At 20oC)24Ω
Rated Operating Power (at 20°C) 6 W
Max. applied voltage16V DC
Contact Arrangement1 Form A
Contact MaterialCopper alloy
Nominal Switching Capacity (Resistive Load) 200A 450V DC (Carry, 60mm2 wire)
Max. Carring Current 200A Continuity
300A 15 min. (60mm2 wire)
Min. Switching Load (Resistive) 1A 12V DC (at 20°C)
Contact Voltage Drop (Initial)Max. 0.1 V (200 A carry current)
Insulation Resistance (Min. MΩ)(Initial)Min. 100 MΩ (At 500 V DC, Measured portion is the same as the case of dielectric strength.)
Dielectric Strength (Between Open Contacts) (Initial)2,500 Vrms for 1min. (detection current: 10mA.)
Dielectric Strength (Between Contacts and Coil) (Initial)2,500 Vrms for 1min. (detection current: 10mA.)
Operate (Set) Time<br>(At Rated Coil Voltage) (At 20oC) (Initial)Max. 50 ms (without bounce)
Release (Reset) Time<br>(at Rated Coil Voltage) (at 20&deg;C) (Initial)Max. 30 ms (with no coil protective elements)
Shock Resistance: Functional For ON: Min. 196 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs)
For OFF: Min. 98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs)
Shock Resistance: DestructiveMin. 490 m/s2 (half-sine shock pulse: 6 ms)
Vibration Resistance: Functional10 to 200 Hz, 43 m/s2 (detection time: 10 µs)
Vibration Resistance: Destructive10 to 200 Hz, 43 m/s2 (Time of vibration for each direction; X, Y, Z direction: 4 hours)
Expected Life: Mechanical LifeMin. 2 x 105
Expected Life: Electrical Life (Resistive)200A 450V DC, Min. 3,000 operations
Expected Life: Switch-Off Life[Forward direction]:
2,000 A 350 V DC, Min. 1 operation
400 A 450 V DC, Min. 50 operations
[Reverse direction]: -200 A 200 V DC, Min. 1,000 operations
Expected Life: Inrush Current (Capacitor)140 A 20 V DC, Min. 70,000 operations
ConditionsAmbient temperature: –40 to +85°C
Humidity: 5 to 85% R.H. (Avoid icing when using at temperatures lower than 0°C.)
Weight (Typ.)Approx. 600 g
Inner Carton (Pieces)1
Outer Carton (Pieces) 10
Usable Voltage Range10 V DC to 16 V DC

Stock check

Model image for AEV17012

AEV17012

Latest Videos

Playlist

Thumbnail for New Product Brief: EV-A Series Automotive Relay

New Product Brief: EV-A Series Automotive Relay

Thumbnail for New Product Brief: TB Series Automotive Relays

New Product Brief: TB Series Automotive Relays

Thumbnail for Panasonic Automotive Solutions for Electrified Drivetrain

Panasonic Automotive Solutions for Electrified Drivetrain