Panasonic EV Series DC Contactors are essentially Relays that combine compact design with cutoff at high DC voltages - something that Panasonic has achieved through contact technology with sealed capsules containing hydrogen gas. They are an eco-friendly design in choice for mobility applications. EV Series DC Contactors are available in 10A to 300A Types. Custom Type DC Contactors are also available from Panasonic.
EV Series Relays (DC Contactors)
Part number list
Results 15
Models table for series EV Series Relays (DC Contactors)
Part No.
Datasheet
Terminal Type
Coil Terminal Structure
Installation Type
Rated Coil Voltage
Contact Capacity
Protective Construction
Operating Function
Operate (Set) Voltage (at20°C) (Initial)
Release (Reset) voltage (at20℃) (Initial)
Rated Operating Current [±10%] (at 20°C)
Coil Resistance (At 20oC)
Rated Operating Power (at 20°C)
Max. applied voltage
Contact Arrangement
Contact Material
Nominal Switching Capacity (Resistive Load)
Max. Carring Current
Min. Switching Load (Resistive)
Contact Voltage Drop (Initial)
Insulation Resistance (Min. MΩ)(Initial)
Dielectric Strength (Between Open Contacts) (Initial)
Dielectric Strength (Between Contacts and Coil) (Initial)
Operate (Set) Time (At Rated Coil Voltage) (At 20oC) (Initial)
Release (Reset) Time (at Rated Coil Voltage) (at 20°C) (Initial)
60A Continuity 100A 10 min. 180A 1 min. (15mm2 wire)
1A 12V DC (at 20°C)
Max. 0.067 V (by voltage drop 6 V DC 20 A)
Min. 100 MΩ (At 500 V DC, Measured portion is the same as the case of dielectric strength.)
2,500 Vrms for 1min. (detection current: 10mA.)
2,500 Vrms for 1min. (detection current: 10mA.)
Max. 50 ms (without bounce)
Max. 50 ms (with no coil protective elements)
For ON: Min. 196 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) For OFF: Min. 98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs)
Min. 490 m/s2 (half-sine shock pulse: 6 ms)
10 to 100 Hz, 43 m/s2 100 to 200 Hz, 19.6 m/s2(detection time: 10 µs)
10 to 100 Hz, 43 m/s2 100 to 200 Hz, 19.6 m/s2 (Time of vibration for each direction; X, Y, Z direction: 4 hours)
Min. 2 x 105
60A 450V DC, Min. 800 operations
[Forward direction]: 600 A 300 V DC, Min. 5 operations 120 A 450 V DC, Min. 50 operations [Reverse direction]: -120 A 200 V DC, Min. 50 operations
60 A 20 V DC, Min. 70,000 operations
[For usage] Ambient temperature: –40 to +80°C (When continuous steady current at 14 V DC:–40 to +65°C Humidity: 5 to 85% R.H. (Avoid icing when using at temperatures lower than 0°C.) [For trasnport and storage] Ambient temperature: –40 to +80°C Humidity: 5 to 85% R.H. (Avoid icing when using at temperatures lower than 0°C.)
60A Continuity 100A 10 min. 180A 1 min. (15mm2 wire)
1A 12V DC (at 20°C)
Max. 0.067 V (by voltage drop 6 V DC 20 A)
Min. 100 MΩ (At 500 V DC, Measured portion is the same as the case of dielectric strength.)
2,000 Vrms for 1min. (detection current: 10mA.)
2,000 Vrms for 1min. (detection current: 10mA.)
Max. 50 ms (without bounce)
Max. 50 ms (with no coil protective elements)
For ON: Min. 196 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) For OFF: Min. 98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs)
Min. 490 m/s2 (half-sine shock pulse: 6 ms)
10 to 100 Hz, 43 m/s2 100 to 200 Hz, 19.6 m/s2(detection time: 10 µs)
10 to 100 Hz, 43 m/s2 100 to 200 Hz, 19.6 m/s2 (Time of vibration for each direction; X, Y, Z direction: 4 hours)
Min. 2 x 105
60A 450V DC, Min. 800 operations
[Forward direction]: 600 A 300 V DC, Min. 5 operations 120 A 450 V DC, Min. 50 operations [Reverse direction]: -120 A 200 V DC, Min. 50 operations
60 A 20 V DC, Min. 70,000 operations
[For usage] Ambient temperature: –40 to +80°C (When continuous steady current at 14 V DC:–40 to +65°C Humidity: 5 to 85% R.H. (Avoid icing when using at temperatures lower than 0°C.) [For trasnport and storage] Ambient temperature: –40 to +80°C Humidity: 5 to 85% R.H. (Avoid icing when using at temperatures lower than 0°C.)
60A Continuity 100A 10 min. 180A 1 min. (15mm2 wire)
1A 12V DC (at 20°C)
Max. 0.067 V (by voltage drop 6 V DC 20 A)
Min. 100 MΩ (At 500 V DC, Measured portion is the same as the case of dielectric strength.)
2,500 Vrms for 1min. (detection current: 10mA.)
2,500 Vrms for 1min. (detection current: 10mA.)
Max. 50 ms (without bounce)
Max. 50 ms (with no coil protective elements)
For ON: Min. 196 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) For OFF: Min. 98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs)
Min. 490 m/s2 (half-sine shock pulse: 6 ms)
10 to 100 Hz, 43 m/s2 100 to 200 Hz, 19.6 m/s2(detection time: 10 µs)
10 to 100 Hz, 43 m/s2 100 to 200 Hz, 19.6 m/s2 (Time of vibration for each direction; X, Y, Z direction: 4 hours)
Min. 2 x 105
60A 450V DC, Min. 800 operations
[Forward direction]: 600 A 300 V DC, Min. 5 operations 120 A 450 V DC, Min. 50 operations [Reverse direction]: -120 A 200 V DC, Min. 50 operations
60 A 20 V DC, Min. 70,000 operations
[For usage] Ambient temperature: –40 to +80°C (When continuous steady current at 14 V DC:–40 to +65°C Humidity: 5 to 85% R.H. (Avoid icing when using at temperatures lower than 0°C.) [For trasnport and storage] Ambient temperature: –40 to +80°C Humidity: 5 to 85% R.H. (Avoid icing when using at temperatures lower than 0°C.)
60A Continuity 100A 10 min. 180A 1 min. (15mm2 wire)
1A 12V DC (at 20°C)
Max. 0.067 V (by voltage drop 6 V DC 20 A)
Min. 100 MΩ (At 500 V DC, Measured portion is the same as the case of dielectric strength.)
2,000 Vrms for 1min. (detection current: 10mA.)
2,000 Vrms for 1min. (detection current: 10mA.)
Max. 50 ms (without bounce)
Max. 50 ms (with no coil protective elements)
For ON: Min. 196 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) For OFF: Min. 98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs)
Min. 490 m/s2 (half-sine shock pulse: 6 ms)
10 to 100 Hz, 43 m/s2 100 to 200 Hz, 19.6 m/s2(detection time: 10 µs)
10 to 100 Hz, 43 m/s2 100 to 200 Hz, 19.6 m/s2 (Time of vibration for each direction; X, Y, Z direction: 4 hours)
Min. 2 x 105
60A 450V DC, Min. 800 operations
[Forward direction]: 600 A 300 V DC, Min. 5 operations 120 A 450 V DC, Min. 50 operations [Reverse direction]: -120 A 200 V DC, Min. 50 operations
60 A 20 V DC, Min. 70,000 operations
[For usage] Ambient temperature: –40 to +80°C (When continuous steady current at 14 V DC:–40 to +65°C Humidity: 5 to 85% R.H. (Avoid icing when using at temperatures lower than 0°C.) [For trasnport and storage] Ambient temperature: –40 to +80°C Humidity: 5 to 85% R.H. (Avoid icing when using at temperatures lower than 0°C.)