Specifications
Item | Performance characteristics |
---|---|
Terminal Type | Screw terminal |
Coil Terminal Structure | Lead wire |
Installation Type | Vertical type |
Rated Coil Voltage | 12V DC |
Contact Capacity | 60 A |
Protective Construction | Capsule contact |
Operating Function | Single side stable |
Operate (Set) Voltage (at20°C) (Initial) | Max. 9 V DC |
Release (Reset) voltage (at20°C) (Initial) | Min. 1 V DC |
Rated Operating Current [±10%] (at 20°C) | 0.375 A |
Coil Resistance (At 20oC) | 32Ω |
Rated Operating Power (at 20°C) | 4.5 W |
Max. applied voltage | 16V DC |
Contact Arrangement | 1 Form A |
Contact Material | Tungsten and copper alloys |
Nominal Switching Capacity (Resistive Load) | 60A 450V DC (Carry, 15mm2 wire) |
Max. Carring Current | 60A Continuity 100A 10 min. 180A 1 min. (15mm2 wire) |
Min. Switching Load (Resistive) | 1A 12V DC (at 20°C) |
Contact Voltage Drop (Initial) | Max. 0.067 V (by voltage drop 6 V DC 20 A) |
Insulation Resistance (Min. MΩ)(Initial) | Min. 100 MΩ (At 500 V DC, Measured portion is the same as the case of dielectric strength.) |
Dielectric Strength (Between Open Contacts) (Initial) | 2,500 Vrms for 1min. (detection current: 10mA.) |
Dielectric Strength (Between Contacts and Coil) (Initial) | 2,500 Vrms for 1min. (detection current: 10mA.) |
Operate (Set) Time<br>(At Rated Coil Voltage) (At 20oC) (Initial) | Max. 50 ms (without bounce) |
Release (Reset) Time<br>(at Rated Coil Voltage) (at 20°C) (Initial) | Max. 50 ms (with no coil protective elements) |
Shock Resistance: Functional | For ON: Min. 196 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) For OFF: Min. 98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) |
Shock Resistance: Destructive | Min. 490 m/s2 (half-sine shock pulse: 6 ms) |
Vibration Resistance: Functional | 10 to 100 Hz, 43 m/s2 100 to 200 Hz, 19.6 m/s2(detection time: 10 µs) |
Vibration Resistance: Destructive | 10 to 100 Hz, 43 m/s2 100 to 200 Hz, 19.6 m/s2 (Time of vibration for each direction; X, Y, Z direction: 4 hours) |
Expected Life: Mechanical Life | Min. 2 x 105 |
Expected Life: Electrical Life (Resistive) | 60A 450V DC, Min. 800 operations |
Expected Life: Switch-Off Life | [Forward direction]: 600 A 300 V DC, Min. 5 operations 120 A 450 V DC, Min. 50 operations [Reverse direction]: -120 A 200 V DC, Min. 50 operations |
Expected Life: Inrush Current (Capacitor) | 60 A 20 V DC, Min. 70,000 operations |
Conditions | [For usage] Ambient temperature: –40 to +80°C (When continuous steady current at 14 V DC:–40 to +65°C Humidity: 5 to 85% R.H. (Avoid icing when using at temperatures lower than 0°C.) [For trasnport and storage] Ambient temperature: –40 to +80°C Humidity: 5 to 85% R.H. (Avoid icing when using at temperatures lower than 0°C.) |
Weight (Typ.) | Approx. 250 g |
Inner Carton (Pieces) | 1 |
Outer Carton (Pieces) | 20 |
Usable Voltage Range | 10 V DC to 16 V DC |
Stock check
AEVS16012
Latest Videos