Specifications

Specifications table for model ACTL3CR3
ItemPerformance characteristics
Rated Coil Voltage12V DC
Coil Resistance (at 20oC)225 Ω
Heat Resistance of TypesPin in Paste compliant type
Contact ArrangementDouble make contact 2 Form A (1 Form U)
Contact TypeStandard type (Ag alloy / Cu clad)
Protective ConstructionFlux tight
Terminal TypePC board type
Operating Function Single side stable
Operate (Set) Voltage (at20°C) (Initial) Max. 6.5 V DC
Release (Reset) voltage (at20°C) (Initial)Min. 0.5 V DC
Rated Operating Current [±10%] (at 20°C)53.3 mA
Coil Resistance (At 20oC)225 Ω
Rated Operating Power (at 20°C) 640 mW
Usable Voltage Range10 to 16V DC
Contact Resistance (Initial)Max. 50mΩ (typ. 2mΩ) (By voltage drop 1A 6V DC)
Contact MaterialAg alloy
Nominal Switching Capacity (Resistive Load) 40A 14V DC
Contact Data: Max. Carrying Current40A/1 hour (Coil applied voltage 12V DC at 20°C 68°F) (Initial)
Min. Switching Load (Resistive) 1A 14V DC (at 20°C 68°F)
Insulation Resistance (Min. MΩ)(Initial)Min. 100 MΩ (at 500V DC, Measurement at same location as [Dielectric strength] section.)
Dielectric Strength (Between Open Contacts) (Initial)500 Vrms for 1min. (Detection current: 10mA.)
Dielectric Strength (Between Contacts and Coil) (Initial)500 Vrms for 1min. (Detection current: 10mA.)
Operate (Set) Time<br>(At Rated Coil Voltage) (At 20oC) (Initial)Max. 10ms (without contact bounce time)
Release (Reset) Time<br>(at Rated Coil Voltage) (at 20&deg;C) (Initial)Max. 10ms (without contact bounce time) (Without diode)
Shock Resistance: Functional Min. 100 m/s2 (Half-wave pulse of sine wave: 11 ms; detection time: 10µs)
Shock Resistance: DestructiveMin. 1,000 m/s2 (Half-wave pulse of sine wave: 6 ms)
Vibration Resistance: Functional10 to 100 Hz, Min. 44.1m/s2 (Detection time: 10µs)
Vibration Resistance: Destructive10 to 500 Hz, Min. 44.1m/s2
Time of vibration for each direction; X, Y direction: 2 hours, Z direction: 4 hours
Expected Life: Mechanical LifeMin. 5 x 106 (at 120 cpm)
Expected Life: Electrical[Resistive load] Min. 105 at rated switching capacity
Operating frequency: 1s ON, 9s OFF

[Resistive and capacitor loads] Min. 105: at 90 A (Inrush), 20 A (Steady), 14 V DC
Operating frequency: 0.15s ON, 4.85s OFF
ConditionsAmbient temperature: –40 to +110°C –40 to +230°F
Humidity: 2 to 85% R.H. (Please avoid icing or condensation)
Weight (Typ.)approx. 6.5g .23 oz
Inner Carton (Pieces)50
Outer Carton (Pieces) 2,000

Stock check

Model image for ACTL3CR3

ACTL3CR3

Latest Videos

Playlist

Thumbnail for New Product Brief: EV-A Series Automotive Relay

New Product Brief: EV-A Series Automotive Relay

Thumbnail for New Product Brief: TB Series Automotive Relays

New Product Brief: TB Series Automotive Relays

Thumbnail for Panasonic Automotive Solutions for Electrified Drivetrain

Panasonic Automotive Solutions for Electrified Drivetrain