Specifications

Specifications table for model ADJ25124
ItemPerformance characteristics
Protective ConstructionFlux-resistant
Operating Function Single side stable
Type ClassificationWith a test button
Rated Coil Voltage24 V DC
Rated Operating Power 250 mW
Contact Arrangement1 Form A
Terminal TypePC board terminal
Insulation Distance[Between contact and coil]
Min. 8 mm (Clearance and Creepage)
Packing Quantity; Inner Carton (Pcs.) 100
Packing Quantity; Outer Carton (Pcs.)500
Rated Operating Current [±10%] (at 20°C)10.4 mA
Resistance [±10%] (at 20°C) 2,304 Ω
Max. Allowable Voltage (at 20°C 68°F)130% V of rated coil voltage
Contact ShapeSingle
Contact Resistance (Initial)Max. 100 mΩ (by voltage drop 6 V DC 1 A)
Contact MaterialAgSnO2 type
Contact Rating (Resistive Load)16 A 250 V AC
Max. Switching Power (Resistive Load) 4,000 VA
Max. Switching Voltage250 V AC
Max. Switching Current16 A (AC)
Min. Switching Load (Reference Value) 100 mA 5 V DC
Insulation Resistance (Initial)Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
Dielectric Strength (Initial): Between Open Contacts1,000 Vrms for 1 min (detection current: 10 mA)
Dielectric Strength (Initial): Between Contact and Coil4,000 Vrms for 1 min (detection current: 10 mA)
Surge Withstand Voltage (Initial): Between Contact and Coil10,000 V
Hock Resistance (Functional)200 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs)
Hock Resistance (Destructive)1,000 m/s2 (half-sine shock pulse: 6 ms)
Vibration Resistance (Functional)10 to 55 Hz (at double amplitude of 2 mm, detection time: 10 μs)
Vibration Resistance (Destructive)10 to 55 Hz (at double amplitude of 3 mm)
Mechanical LifeMin. 5x106 ope. (switching frequency: at 180 times/min)
ConditionsAmbient temperature: -40 to +70℃
Humidity: 5 to 85% RH (Avoid icing and condensation)
Weight (Typ.)Approx. 14 g
Resistive Load[switching frequency: 20 times/min]
Min. 100x103 ope. 16 A 250 V AC
Operate Voltage (@20oC)Max. 75% V of rated coil voltage (Initial)
Release Voltage (at20°C) Min. 10% V of rated coil voltage (Initial)
Operate Time (Initial) (At 20oC)Max. 20 ms at rated coil voltage (without bounce)
Release Time (Initial) (at 20°C) Max. 20 ms at rated coil voltage (without bounce, without diode)

Stock check

Model image for ADJ25124

ADJ25124

Latest Videos

Playlist

Thumbnail for Panasonic Industrial Solutions for 5G Networking Applications

Panasonic Industrial Solutions for 5G Networking Applications

Thumbnail for New Product Spotlight: DW Series Relays

New Product Spotlight: DW Series Relays

Thumbnail for New Product Spotlight: PA-N Series General Power Relays

New Product Spotlight: PA-N Series General Power Relays

Thumbnail for New Product Introduction: HE-R Series General Power Relays

New Product Introduction: HE-R Series General Power Relays

Thumbnail for New Product Introduction: HE Series Power Relay PV Type 90A Wide Gap

New Product Introduction: HE Series Power Relay PV Type 90A Wide Gap

Thumbnail for New Product Introduction: DS-P Series

New Product Introduction: DS-P Series

Thumbnail for New Product Information: LQ Series Relays

New Product Information: LQ Series Relays

Thumbnail for New Product Introduction: HE-A Series Relays

New Product Introduction: HE-A Series Relays

Thumbnail for Automotive Solutions and Applications

Automotive Solutions and Applications

Thumbnail for New Product Introduction: DW Series Relays

New Product Introduction: DW Series Relays