Maximize Switch Capacity. Minimize Power Consumption.
Panasonic's HE Relays PV Type are available in multiple different contact ratings: 35A, 48A, 90A, and New 90A Wide Gap!
These Relays have a 1 Form A (SPST-NO) contact arrangement in a PC Board mountable small case size. HE Relays PV Type features the minimum contact gap and 2.5kW surge breakdown required by photovoltaic standard requirements. These Relays contribute to overall energy savings with low coil holding voltage that can be reduced down to just 40% of the nominal coil voltage. These Relays provide the necessary high switching capacity and low power consumption required by energy management applications.
Features of the HE Relay PV Type
High Capacity Contact Rating: 35A, 48A, or 90A types
Compact Case Size: 35A/48A - 33 x 38 x 36.3H mm, 90A - 33 x 38 x 38.8H mm
PCB Mounted
Low Coil Holding Power
Large Contact Gap: 35A/48A - 2.5 mm, 90A - 3.0 mm
High Surge Breakdown Voltage: 2.5kW
RoHS/REACH Compliant
Benefits of the HE Relay PV Type
High-Capacity Control
Takes Up Less Board Space
Easier Assembly For High-Volume Projects
Low Power Operation
Meets VDE0126 and EN61810-1
Environmentally Friendly
HE Series Relays PV Type
Part number list
Results 16
Models table for series HE Series Relays PV Type
Part No.
Datasheet
Contact Gap
Rated Coil Voltage
Contact Arrangement
Max. Switching Current
Protective Construction
Operating Function
Terminal Type
Contact Type
Packing Quantity; Inner Carton (Pcs.)
Packing Quantity; Outer Carton (Pcs.)
Operate Voltage (@20oC)
Release Voltage (at20°C)
Rated Operating Current [±10%] (at 20°C)
Resistance [±10%] (at 20°C)
Rated Operating Power
Max. Allowable Voltage (at 20°C 68°F)
Contact Shape
Contact Resistance (Initial)
Contact Material
Contact Rating (Resistive Load)
Max. Switching Power (Resistive Load)
Max. Switching Voltage
Min. Switching Load (Reference Value)
Insulation Resistance (Initial)
Dielectric Strength (Initial): Between Contact and Coil
Dielectric Strength (Initial): Between Open Contacts
Surge Withstand Voltage (Initial): Between Contact and Coil
10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 1.5 mm)
Min. 10x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -50 to +85℃ (When using at 55℃ or higher, the coil holding voltage should be 50% V to 60% V) Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 80 g
[at 85℃, switching frequency ON : OFF = 1 s : 9 s] Min. 30x103 ope. 48 A 277 V AC Min. 30x103 ope. 48 A 30 V DC
[room temperature, switching frequency ON : OFF = 1 s : 9 s] Min. 10x103 ope. 48 A 490 V AC Min. 10x103 ope. 48 A 48 V DC
Carton
[at 85℃, switching frequency ON : OFF = 0.1 s : 10 s] Min. 30x103 ope. 48 A 250 V AC (cosΦ = 0.8) Min. 50 ope. 72 A 250 V AC (cosΦ = 0.8)
10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 1.5 mm)
Min. 10x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -50 to +85℃ (When using at 55℃ or higher, the coil holding voltage should be 50% V to 60% V) Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 80 g
[at 85℃, switching frequency ON : OFF = 1 s : 9 s] Min. 30x103 ope. 48 A 277 V AC Min. 30x103 ope. 48 A 30 V DC
[room temperature, switching frequency ON : OFF = 1 s : 9 s] Min. 10x103 ope. 48 A 490 V AC Min. 10x103 ope. 48 A 48 V DC
Carton
[at 85℃, switching frequency ON : OFF = 0.1 s : 10 s] Min. 30x103 ope. 48 A 250 V AC (cosΦ = 0.8) Min. 50 ope. 72 A 250 V AC (cosΦ = 0.8)
10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 1.5 mm)
Min. 106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -50 to +85℃ (When using at 55℃ or higher, the coil holding voltage should be 50% V to 60% V) Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 85 g
[at 85℃, switching frequency ON : OFF = 1 s : 9 s] Min. 10x103 ope. 60 A 277 V AC Min. 103 ope. 90 A 277 V AC Min. 103 ope. 90 A 60 V DC
[room temperature, switching frequency ON : OFF = 1 s : 9 s] Min. 10x103 ope. 60 A 490 V AC Min. 10x103 ope. 80 A 277 V AC Min. 10x103 ope. 80 A 48 V DC
10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 1.5 mm)
Min. 10x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -50 to +85℃ (When using at 55℃ or higher, the coil holding voltage should be 50% V to 60% V) Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 80 g
[room temperature, switching frequency: 20 times/min] Min. 200x103 ope. 30 A 250 V AC
[at 85℃, switching frequency ON : OFF = 1 s : 9 s] Min. 30x103 ope. 35 A 277 V AC
[room temperature, switching frequency ON : OFF = 1 s : 9 s] Min. 10x103 ope. 35 A 490 V AC Min. 10x103 ope. 35 A 48 V DC
10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 1.5 mm)
Min. 106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -50 to +85℃ (When using at 55℃ or higher, the coil holding voltage should be 50% V to 60% V) Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 85 g
[at 85℃, switching frequency ON : OFF = 1 s : 9 s] Min. 10x103 ope. 60 A 277 V AC Min. 103 ope. 90 A 277 V AC Min. 103 ope. 90 A 60 V DC
[room temperature, switching frequency ON : OFF = 1 s : 9 s] Min. 103 ope. 55 A 800 V AC Min. 10x103 ope. 60 A 490 V AC Min. 10x103 ope. 80 A 277 V AC Min. 10x103 ope. 80 A 48 V DC
10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 1.5 mm)
Min. 106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -50 to +85℃ (When using at 55℃ or higher, the coil holding voltage should be 50% V to 60% V) Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 85 g
[at 85℃, switching frequency ON : OFF = 1 s : 9 s] Min. 10x103 ope. 60 A 277 V AC Min. 103 ope. 90 A 277 V AC Min. 103 ope. 90 A 60 V DC
[room temperature, switching frequency ON : OFF = 1 s : 9 s] Min. 10x103 ope. 60 A 490 V AC Min. 10x103 ope. 80 A 277 V AC Min. 10x103 ope. 80 A 48 V DC
10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 1.5 mm)
Min. 106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -50 to +85℃ (When using at 55℃ or higher, the coil holding voltage should be 50% V to 60% V) Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 85 g
[at 85℃, switching frequency ON : OFF = 1 s : 9 s] Min. 10x103 ope. 60 A 277 V AC Min. 103 ope. 90 A 277 V AC Min. 103 ope. 90 A 60 V DC
[room temperature, switching frequency ON : OFF = 1 s : 9 s] Min. 10x103 ope. 60 A 490 V AC Min. 10x103 ope. 80 A 277 V AC Min. 10x103 ope. 80 A 48 V DC
10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 1.5 mm)
Min. 10x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -50 to +85℃ (When using at 55℃ or higher, the coil holding voltage should be 50% V to 60% V) Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 80 g
[room temperature, switching frequency: 20 times/min] Min. 200x103 ope. 30 A 250 V AC
[at 85℃, switching frequency ON : OFF = 1 s : 9 s] Min. 30x103 ope. 35 A 277 V AC
[room temperature, switching frequency ON : OFF = 1 s : 9 s] Min. 10x103 ope. 35 A 490 V AC Min. 10x103 ope. 35 A 48 V DC
10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 1.5 mm)
Min. 10x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -50 to +85℃ (When using at 55℃ or higher, the coil holding voltage should be 50% V to 60% V) Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 80 g
[room temperature, switching frequency: 20 times/min] Min. 200x103 ope. 30 A 250 V AC
[at 85℃, switching frequency ON : OFF = 1 s : 9 s] Min. 30x103 ope. 35 A 277 V AC
[room temperature, switching frequency ON : OFF = 1 s : 9 s] Min. 10x103 ope. 35 A 490 V AC Min. 10x103 ope. 35 A 48 V DC
10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 1.5 mm)
Min. 10x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -50 to +85℃ (When using at 55℃ or higher, the coil holding voltage should be 50% V to 60% V) Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 80 g
[at 85℃, switching frequency ON : OFF = 1 s : 9 s] Min. 30x103 ope. 48 A 277 V AC Min. 30x103 ope. 48 A 30 V DC
[room temperature, switching frequency ON : OFF = 1 s : 9 s] Min. 10x103 ope. 48 A 490 V AC Min. 10x103 ope. 48 A 48 V DC
Carton
[at 85℃, switching frequency ON : OFF = 0.1 s : 10 s] Min. 30x103 ope. 48 A 250 V AC (cosΦ = 0.8) Min. 50 ope. 72 A 250 V AC (cosΦ = 0.8)
Models table for series HE Series Relays PV Type
Part No.
Datasheet
Contact Gap
Rated Coil Voltage
Contact Arrangement
Max. Switching Current
Protective Construction
Operating Function
Terminal Type
Contact Type
Packing Quantity; Inner Carton (Pcs.)
Packing Quantity; Outer Carton (Pcs.)
Operate Voltage (@20oC)
Release Voltage (at20°C)
Rated Operating Current [±10%] (at 20°C)
Resistance [±10%] (at 20°C)
Rated Operating Power
Max. Allowable Voltage (at 20°C 68°F)
Contact Shape
Contact Resistance (Initial)
Contact Material
Contact Rating (Resistive Load)
Max. Switching Power (Resistive Load)
Max. Switching Voltage
Min. Switching Load (Reference Value)
Insulation Resistance (Initial)
Dielectric Strength (Initial): Between Contact and Coil
Dielectric Strength (Initial): Between Open Contacts
Surge Withstand Voltage (Initial): Between Contact and Coil
10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 1.5 mm)
Min. 10x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -50 to +85℃ (When using at 55℃ or higher, the coil holding voltage should be 50% V to 60% V) Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 80 g
[at 85℃, switching frequency ON : OFF = 1 s : 9 s] Min. 30x103 ope. 48 A 277 V AC Min. 30x103 ope. 48 A 30 V DC
[room temperature, switching frequency ON : OFF = 1 s : 9 s] Min. 10x103 ope. 48 A 490 V AC Min. 10x103 ope. 48 A 48 V DC
Carton
[at 85℃, switching frequency ON : OFF = 0.1 s : 10 s] Min. 30x103 ope. 48 A 250 V AC (cosΦ = 0.8) Min. 50 ope. 72 A 250 V AC (cosΦ = 0.8)
10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 1.5 mm)
Min. 10x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -50 to +85℃ (When using at 55℃ or higher, the coil holding voltage should be 50% V to 60% V) Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 80 g
[at 85℃, switching frequency ON : OFF = 1 s : 9 s] Min. 30x103 ope. 48 A 277 V AC Min. 30x103 ope. 48 A 30 V DC
[room temperature, switching frequency ON : OFF = 1 s : 9 s] Min. 10x103 ope. 48 A 490 V AC Min. 10x103 ope. 48 A 48 V DC
Carton
[at 85℃, switching frequency ON : OFF = 0.1 s : 10 s] Min. 30x103 ope. 48 A 250 V AC (cosΦ = 0.8) Min. 50 ope. 72 A 250 V AC (cosΦ = 0.8)
10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 1.5 mm)
Min. 106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -50 to +85℃ (When using at 55℃ or higher, the coil holding voltage should be 50% V to 60% V) Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 85 g
[at 85℃, switching frequency ON : OFF = 1 s : 9 s] Min. 10x103 ope. 60 A 277 V AC Min. 103 ope. 90 A 277 V AC Min. 103 ope. 90 A 60 V DC
[room temperature, switching frequency ON : OFF = 1 s : 9 s] Min. 10x103 ope. 60 A 490 V AC Min. 10x103 ope. 80 A 277 V AC Min. 10x103 ope. 80 A 48 V DC
10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 1.5 mm)
Min. 10x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -50 to +85℃ (When using at 55℃ or higher, the coil holding voltage should be 50% V to 60% V) Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 80 g
[room temperature, switching frequency: 20 times/min] Min. 200x103 ope. 30 A 250 V AC
[at 85℃, switching frequency ON : OFF = 1 s : 9 s] Min. 30x103 ope. 35 A 277 V AC
[room temperature, switching frequency ON : OFF = 1 s : 9 s] Min. 10x103 ope. 35 A 490 V AC Min. 10x103 ope. 35 A 48 V DC
10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 1.5 mm)
Min. 106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -50 to +85℃ (When using at 55℃ or higher, the coil holding voltage should be 50% V to 60% V) Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 85 g
[at 85℃, switching frequency ON : OFF = 1 s : 9 s] Min. 10x103 ope. 60 A 277 V AC Min. 103 ope. 90 A 277 V AC Min. 103 ope. 90 A 60 V DC
[room temperature, switching frequency ON : OFF = 1 s : 9 s] Min. 103 ope. 55 A 800 V AC Min. 10x103 ope. 60 A 490 V AC Min. 10x103 ope. 80 A 277 V AC Min. 10x103 ope. 80 A 48 V DC
10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 1.5 mm)
Min. 106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -50 to +85℃ (When using at 55℃ or higher, the coil holding voltage should be 50% V to 60% V) Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 85 g
[at 85℃, switching frequency ON : OFF = 1 s : 9 s] Min. 10x103 ope. 60 A 277 V AC Min. 103 ope. 90 A 277 V AC Min. 103 ope. 90 A 60 V DC
[room temperature, switching frequency ON : OFF = 1 s : 9 s] Min. 10x103 ope. 60 A 490 V AC Min. 10x103 ope. 80 A 277 V AC Min. 10x103 ope. 80 A 48 V DC
10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 1.5 mm)
Min. 106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -50 to +85℃ (When using at 55℃ or higher, the coil holding voltage should be 50% V to 60% V) Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 85 g
[at 85℃, switching frequency ON : OFF = 1 s : 9 s] Min. 10x103 ope. 60 A 277 V AC Min. 103 ope. 90 A 277 V AC Min. 103 ope. 90 A 60 V DC
[room temperature, switching frequency ON : OFF = 1 s : 9 s] Min. 10x103 ope. 60 A 490 V AC Min. 10x103 ope. 80 A 277 V AC Min. 10x103 ope. 80 A 48 V DC
10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 1.5 mm)
Min. 10x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -50 to +85℃ (When using at 55℃ or higher, the coil holding voltage should be 50% V to 60% V) Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 80 g
[room temperature, switching frequency: 20 times/min] Min. 200x103 ope. 30 A 250 V AC
[at 85℃, switching frequency ON : OFF = 1 s : 9 s] Min. 30x103 ope. 35 A 277 V AC
[room temperature, switching frequency ON : OFF = 1 s : 9 s] Min. 10x103 ope. 35 A 490 V AC Min. 10x103 ope. 35 A 48 V DC
10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 1.5 mm)
Min. 10x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -50 to +85℃ (When using at 55℃ or higher, the coil holding voltage should be 50% V to 60% V) Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 80 g
[room temperature, switching frequency: 20 times/min] Min. 200x103 ope. 30 A 250 V AC
[at 85℃, switching frequency ON : OFF = 1 s : 9 s] Min. 30x103 ope. 35 A 277 V AC
[room temperature, switching frequency ON : OFF = 1 s : 9 s] Min. 10x103 ope. 35 A 490 V AC Min. 10x103 ope. 35 A 48 V DC
10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 1.5 mm)
Min. 10x106 ope. (switching frequency: at 180 times/min)
Ambient temperature: -50 to +85℃ (When using at 55℃ or higher, the coil holding voltage should be 50% V to 60% V) Humidity: 5 to 85% RH (Avoid icing and condensation)
Approx. 80 g
[at 85℃, switching frequency ON : OFF = 1 s : 9 s] Min. 30x103 ope. 48 A 277 V AC Min. 30x103 ope. 48 A 30 V DC
[room temperature, switching frequency ON : OFF = 1 s : 9 s] Min. 10x103 ope. 48 A 490 V AC Min. 10x103 ope. 48 A 48 V DC
Carton
[at 85℃, switching frequency ON : OFF = 0.1 s : 10 s] Min. 30x103 ope. 48 A 250 V AC (cosΦ = 0.8) Min. 50 ope. 72 A 250 V AC (cosΦ = 0.8)
Solar Storage Solutions
Solutions to Help Reduce Energy Consumption
In today’s environmentally conscious world, Solar Storage is an increasingly popular system that captures energy and stores it to perform operations in the future. These Systems involve converting many forms of energy, such as electrical potential energy or kinetic energy, into more economically storable formats for short-term and long-term use. Panasonic product solutions include Relays, Passive Components, such as Capacitors, Metal Oxide Varistors, and more.
Find the latest new product details here, with a convenient PDF product summary document. Quickly access and download the latest product information for the new HE Series Relays PV Type, including product specifications, features, benefits, industries and applications, software, block diagrams, and technical characteristics.