Specifications

Specifications table for model S2EB-L2-5V
ItemPerformance characteristics
Operating Function 2 coil latching
Rated Coil Voltage5 V DC
Rated Operating Power 192 mW
Contact Arrangement2 Form A 2 Form B
Protective ConstructionSealed
Terminal TypePC board terminal
AccessoriesSockets are available.
Packing Quantity; Inner Carton (Pcs.) 50
Packing Quantity; Outer Carton (Pcs.)500
Rated Operating Current [±10%] (at 20°C)Set coil: 38.5 mA
Reset coil: 38.5 mA
Resistance [±10%] (at 20°C) Set coil: 130 Ω
Reset coil: 130 Ω
Max. Allowable Voltage 180% V of rated coil voltage (at 40℃)
Contact ShapeTwin
Contact Resistance (Initial)Max. 50 mΩ (by voltage drop 6 V DC 1 A)
Contact MaterialDouble layer contact of AgNi-AgSnO2 type + Au clad
Contact Rating (Resistive Load)4 A 250 V AC, 3 A 30 V DC
Max. Switching Power (Resistive Load) 1,000 VA, 90 W
Max. Switching Voltage250 V AC, 48 V DC
Max. Switching Current4 A (AC), 3 A (DC) (30 to 48 V DC at less than 0.5 A)
Min. Switching Load (Reference Value) 100 μA 100 mV DC
Insulation Resistance (Initial)Min. 10,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
Dielectric Strength (Initial): Between Open Contacts750 Vrms for 1 min (detection current: 10 mA)
Dielectric Strength (Initial): Between Contact Sets1,000 Vrms for 1 min (detection current: 10 mA)
Dielectric Strength (Initial): Between Contact and Coil1,500 Vrms for 1 min (detection current: 10 mA)
Hock Resistance (Functional)490 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs)
Hock Resistance (Destructive)980 m/s2 (half-sine shock pulse: 6 ms)
Vibration Resistance (Functional)10 to 55 Hz (at double amplitude of 3 mm, detection time: 10 μs)
Vibration Resistance (Destructive)10 to 55 Hz (at double amplitude of 4 mm)
Mechanical LifeMin. 100x106 ope. (switching frequency: at 50 cps)
ConditionsAmbient temperature: -55 to +65℃
Humidity: 5 to 85% RH (Avoid icing and condensation)
Weight (Typ.)Approx. 8 g
Resistive Load[switching frequency: 20 times/min]
Min. 200x103 ope. 3 A 30 V DC
Min. 100x103 ope. 4 A 250 V AC
Set Voltage Max. 70% V of rated coil voltage (Initial)
Reset VoltageMax. 70% V of rated coil voltage (Initial)
Time (Initial) (at 20°C 68°F) (Initial) Max. 15 ms at rated coil voltage (without bounce)
Reset Time (Initial) (at20°C 68°F) Max. 15 ms at rated coil voltage (without bounce, without diode)

Stock check

S2EB-L2-5V

Latest Videos

Playlist

Thumbnail for Why Should A Relay Meet The New NEMA 410 Standard? (S1 E1)

Why Should A Relay Meet The New NEMA 410 Standard? (S1 E1)

Thumbnail for Smart Grid Products: LF-G Series Power Relays

Smart Grid Products: LF-G Series Power Relays

Thumbnail for Smart Grid Products: HE-V Series Power Relays

Smart Grid Products: HE-V Series Power Relays

Thumbnail for Features and Benefits of PhotoMOS®

Features and Benefits of PhotoMOS®

Thumbnail for Introduction to PhotoMOS®

Introduction to PhotoMOS®

Thumbnail for Where Technology Meets Humanity

Where Technology Meets Humanity

Thumbnail for Panasonic Industrial Solutions for 5G Networking Applications

Panasonic Industrial Solutions for 5G Networking Applications

Thumbnail for New Product Spotlight: DW Series Relays

New Product Spotlight: DW Series Relays

Thumbnail for New Product Spotlight: PhotoMOS® HE 1 Form A and HE SOP 1 Form A Series Relays

New Product Spotlight: PhotoMOS® HE 1 Form A and HE SOP 1 Form A Series Relays

Thumbnail for New Product Spotlight: PA-N Series General Power Relays

New Product Spotlight: PA-N Series General Power Relays