ItemPerformance characteristics
Terminal TypeScrew terminal
Coil Terminal StructureFaston terminal
Installation TypeHorizontal type
Rated Coil Voltage12V DC
Contact Capacity60 A
Protective ConstructionCapsule contact
Operating Function Single side stable
Operate (Set) Voltage (at20°C) (Initial) Max. 9 V DC
Release (Reset) voltage (at20°C) (Initial)Min. 1 V DC
Rated Operating Current [±10%] (at 20°C)0.375 A
Coil Resistance (At 20oC)32Ω
Rated Operating Power (at 20°C) 4.5 W
Max. applied voltage16V DC
Contact Arrangement1 Form A
Contact MaterialTungsten and copper alloys
Nominal Switching Capacity (Resistive Load) 60A 450V DC (Carry, 15mm2 wire)
Max. Carring Current 60A Continuity
100A 10 min.
180A 1 min. (15mm2 wire)
Min. Switching Load (Resistive) 1A 12V DC (at 20°C)
Contact Voltage Drop (Initial)Max. 0.067 V (by voltage drop 6 V DC 20 A)
Insulation Resistance (Min. MΩ)(Initial)Min. 100 MΩ (At 500 V DC, Measured portion is the same as the case of dielectric strength.)
Dielectric Strength (Between Open Contacts) (Initial)2,000 Vrms for 1min. (detection current: 10mA.)
Dielectric Strength (Between Contacts and Coil) (Initial)2,000 Vrms for 1min. (detection current: 10mA.)
Operate (Set) Time<br>(At Rated Coil Voltage) (At 20oC) (Initial)Max. 50 ms (without bounce)
Release (Reset) Time<br>(at Rated Coil Voltage) (at 20&deg;C) (Initial)Max. 50 ms (with no coil protective elements)
Shock Resistance: Functional For ON: Min. 196 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs)
For OFF: Min. 98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs)
Shock Resistance: DestructiveMin. 490 m/s2 (half-sine shock pulse: 6 ms)
Vibration Resistance: Functional10 to 100 Hz, 43 m/s2
100 to 200 Hz, 19.6 m/s2(detection time: 10 µs)
Vibration Resistance: Destructive10 to 100 Hz, 43 m/s2
100 to 200 Hz, 19.6 m/s2 (Time of vibration for each direction; X, Y, Z direction: 4 hours)
Expected Life: Mechanical LifeMin. 2 x 105
Expected Life: Electrical Life (Resistive)60A 450V DC, Min. 800 operations
Expected Life: Switch-Off Life[Forward direction]:
600 A 300 V DC, Min. 5 operations
120 A 450 V DC, Min. 50 operations
[Reverse direction]: -120 A 200 V DC, Min. 50 operations
Expected Life: Inrush Current (Capacitor)60 A 20 V DC, Min. 70,000 operations
Conditions[For usage] Ambient temperature: –40 to +80°C (When continuous steady current at 14 V DC:–40 to +65°C
Humidity: 5 to 85% R.H. (Avoid icing when using at temperatures lower than 0°C.)
[For trasnport and storage] Ambient temperature: –40 to +80°C
Humidity: 5 to 85% R.H. (Avoid icing when using at temperatures lower than 0°C.)
Weight (Typ.)Approx. 240 g
Inner Carton (Pieces)1
Outer Carton (Pieces) 20
Usable Voltage Range10 V DC to 16 V DC

Stock check

AEVS960122

Latest Videos

Playlist

Thumbnail for Why Should A Relay Meet The New NEMA 410 Standard? (S1 E1)

Why Should A Relay Meet The New NEMA 410 Standard? (S1 E1)

Thumbnail for Smart Grid Products: LF-G Series Power Relays

Smart Grid Products: LF-G Series Power Relays

Thumbnail for Smart Grid Products: HE-V Series Power Relays

Smart Grid Products: HE-V Series Power Relays

Thumbnail for Features and Benefits of PhotoMOS®

Features and Benefits of PhotoMOS®

Thumbnail for Introduction to PhotoMOS®

Introduction to PhotoMOS®

Thumbnail for Where Technology Meets Humanity

Where Technology Meets Humanity

Thumbnail for Panasonic Industrial Solutions for 5G Networking Applications

Panasonic Industrial Solutions for 5G Networking Applications

Thumbnail for New Product Spotlight: DW Series Relays

New Product Spotlight: DW Series Relays

Thumbnail for New Product Spotlight: PhotoMOS® HE 1 Form A and HE SOP 1 Form A Series Relays

New Product Spotlight: PhotoMOS® HE 1 Form A and HE SOP 1 Form A Series Relays

Thumbnail for New Product Spotlight: PA-N Series General Power Relays

New Product Spotlight: PA-N Series General Power Relays