Specifications
Item | Performance characteristics |
---|---|
Terminal Type | Surface-mount terminal |
Operating Function | Single side stable type |
Rated Operating Power | 140mW |
Coil Voltage | 6V DC |
Surface-Mount Terminal Type | SS type |
Packing Quantity | Tube packing |
Protective Construction | Sealed Type |
Contact Type | Power type |
Contact Arrangement | 2 Form C |
Contact Material | Ag+Au plating |
Pick-Up Voltage | 75%V or less of nominal voltage (Initial) |
Input side: Drop-out Voltage | 10%V or more of nominal voltage (Initial) |
Nominal Switching Capacity (Resistive Load) | 2A 30V DC, 0.5A 125V AC |
Max. Switching Current | 7.5 A (Inrush) |
Min. Switching Capacity | 10µA 10mV DC |
Breakdown Voltage (Initial) : Between Open Contacts | 1,000 Vrms for 1min. (Detection current: 10mA.) |
Breakdown Voltage (Initial) : Between Contact And Coil | 2,000 Vrms for 1min. (Detection current: 10mA.) |
Breakdown Voltage (Contact-Contact) (Initial) | 1,000 Vrms for 1min. (Detection current: 10mA.) |
Surge Breakdown Voltage (Initial): Between Open Contacts | 1,500 V (10 x 160µs) (FCC Part 68) |
Surge Breakdown Voltage (Initial): Between Contacts and Coil | 2,500 V (2 x 10µs) (Telcordia) |
Expected Life: Mechanical | Min. 108 (at 180 cpm) |
Expected Life: Electrical | Min. 105 (2 A 30 V DC resistive), 5×105 (1 A 30 V DC resistive), Min. 105 (0.5 A 125 V AC resistive) (at 20 cpm) Min. 2×105 [7.5 A inrush (250 ms)/1.5 A normal 30 V AC (cosΦ= 0.4)] (ON/OFF = 1s/9s) |
Conditions | Ambient temperature: –40 to +85°C –40 to +185°F Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature) |
Height (mm) | 8.4 |
Weight (Typ.) | Approx. 2 g .071 oz |
Packing Quantity; Inner Carton (Pcs.) | 40 |
Packing Quantity; Outer Carton (Pcs.) | 1000 |
Max.switching current (*) | Inrush: 7.5 A, Steady: 2 A When used at 7.5 A. Regarding connection method, you must follow the precaution, Connection of No (pin #5 and #8) and COM (pin #4 and #9) in the cricuit is required. |
Stock check
TX2SS-6V-TH
What's New