Item | Performance characteristics |
---|---|
Applicable Sensor Heads | HL-D301B, HL-D301C |
Connectable sensor heads | Number of connectable units: Max. 2 units |
Supply Voltage | 24 V DC ±10 % including ripple 0.5 V (P-P) |
Current Consumption | 1 A or less (when 2 sensor heads are connected) |
Sampling Rate | Depends on the sensing mode and settings Multi-zone beam control mode : Standard 12.2 ms (Note 1) Whole synchronized measurement mode : Max. 2.5 ms (Note 2) Multi-select displacement sensing mode : Max. 80 μs (Note 3) (Note 1):Value for using two judgment outputs with 1 sensor head in MZBC mode, with each measuring range set to Max. and light intensity not adjusted (continuous sensing). (Note 2):Value for obtaining displacement shape waveform data using buffering and 2 sensor heads in whole synchronized measurement mode, with each measuring range set to Min. (no OUT calculation). (Note 3):Value for using 2 judgment outputs with 1 sensor head in MSDS mode, with the unit light receiving time set to 40 μs, light intensity not adjusted (continuous), and 2 points selected (without wide cell function). |
Judgement Output | N-channel FET, open drain • Maximum sink current: 100 mA • Applied voltage: 30 V DC or less (between output terminal and 0 V) • ON-resistance: 5 Ω or less |
Judgment Output: Output Operation | Open during output operation (switchable) |
Judgment Output: Short-Circuit Protection | Incorporated |
Alarm Output | N-channel FET, open drain • Maximum sink current: 100 mA • Applied voltage: 30 V DC or less (between output terminal and 0 V) • ON-resistance: 5 Ω or less |
Alarm Output : Output Operation | Open when alarm is triggered (switchable) |
Alarm Output : Short-Circuit Protection | Incorporated |
External Trigger Input | Photocoupler insulation input |
External Trigger Input: Input Operation | ON: short-circuiting to external insulation COM (-) , OFF: when open |
External Trigger Input: Applied Voltage | 30 V DC or less (leakage current: 0.1 mA or less) |
Laser Control Input | Photocoupler insulation input |
Laser Control Input: Input Operation | Laser emission: short-circuiting to external insulation COM (-) , Laser emission OFF: when open |
Laser Control Input: Applied Voltage | 30 V DC or less (leakage current: 0.1 mA or less) |
Zero Set Input | Photocoupler insulation input |
Zero Set Input: Input Operation | ON: short-circuiting to external insulation COM (-) , OFF: when open |
Zero Set Input: Applied Voltage | 30 V DC or less (leakage current: 0.1 mA or less) |
Timing Input | Photocoupler insulation input |
Timing Input: Input Operation | ON: short-circuiting to external insulation COM (-) , OFF: when open |
Timing Input: Applied Voltage | 30 V DC or less (leakage current: 0.1 mA or less) |
Reset Input | Photocoupler insulation input |
Reset Input: Input Operation | ON: short-circuiting to external insulation COM (-) , OFF: when open |
Reset Input: Applied Voltage | 30 V DC or less (leakage current: 0.1 mA or less) |
RS-232C Interface | Baud rate: 9,600, 19,200, 38,400, 57,600, 115,200 bit/s(Note):Products produced from September 2013 (Ver. 2) are also compatible with 9,600, 19,200 and 38,400 bit/s. |
Settings/Data Display | HL-D3SMI (accessory) or dedicated API |
USB Interface | USB 2.0 full-speed (USB 1.1 compatible) |
Indicator: Power | Green LED (lights up at power on) |
Indicator: Sensor Head A Laser Radiation | Green LED [During continuous sensing: lights up during laser emission, blinks twice when turning off During sensing stop process: alternately lights up during laser emission (ON: 1 sec / OFF: 1 sec), blinks once when turning off] |
Indicator: Sensor Head B Laser Radiation | Green LED [During continuous sensing: lights up during laser emission, blinks twice when turning off During sensing stop process: alternately lights up during laser emission (ON: 1 sec / OFF: 1 sec), blinks once when turning off] |
Indicator: Alarm | Red LED (lights up when there is a sensing alarm or sensor head wire breakage) |
Environmental Resistance: Ambient Temperature | 0 to +50 ℃ +32 to +122 ℉ (No dew condensation or icing allowed), Storage: -20 to +70 ℃ -4 to +158 ℉ |
Environmental Resistance: Ambient Humidity | 35 to 85 % RH , Storage: 35 to 85 % RH |
Environmental Resistance: Vibration Resistance | 10 to 55 Hz frequency (period: 1 min) , 0.75 mm 0.030 in double amplitude in X, Y, and Z directions for 30 min. each |
Environmental Resistance: Shock Resistance | 196 m/s2 acceleration (20G approx.) in X, Y, and Z directions three times each |
Material | Enclosure: Aluminum |
Weight (Typ.) | 300 g approx. |
Accessory | HL-D3 set-up CD-ROM, (including HL-D3SMI and User's Manual), Instruction manual, USB cable (2 m 6.562 ft) |