Item | Performance characteristics |
---|---|
Rated Pressure Range | DPH-L113V : -0.1 to +1 MPa DPH-L113 : 0 to +1 MPa DPH-L133 : 0 to +3.5 MPa DPH-L114 : 0 to +10 MPa DPH-L154 : 0 to +50 MPa (Note) : Values differ depending on a connected sensor head. |
Set Pressure Range | [DPH-L113V] -1.177 to +1.177 MPa -12.00 to +12.00 kgf/cm2 -11.77 to +11.77 bar -170.6 to +170.6 psi [DPH-L113] -1.070 to +1.070 MPa -10.91 to +10.91 kgf/cm2 -10.70 to +10.70 bar -155.2 to +155.2 psi [DPH-L133] -3.74 to +3.74 MPa -38.1 to +38.1 kgf/cm2 -37.4 to +37.4 bar -542 to +542 psi [DPH-L114] -10.70 to +10.70 MPa -109.1 to +109.1 kgf/cm2 -107.0 to +107.0 bar -1552 to +1552 psi [DPH-L154] -53.5 to +53.5 MPa -545 to +545 kgf/cm2 -535 to +535 bar -1980 to +7760 psi (Note) : Values differ depending on a connected sensor head. |
Set Pressure Resolution | DPH-L113V : 0.001 MPa DPH-L113 : 0.001 MPa DPH-L133 : 0.01 MPa DPH-L114 : 0.01 MPa DPH-L154 : 0.1 MPa (Note): Values differ depending on a connected sensor head. |
Display | 4 digits +4 digits 3-color LCD display (Display refresh rate : 250 ms, 500 ms, 1,000 ms, selectable by key operation) |
Display: Displayable Pressure Range | [DPH-L113V] -0.155 to +1.022 MPa -1.58 to +10.42 kgf/cm2 -1.55 to +10.22 bar -22.4 to +148.2 psi [DPH-L113] -0.050 to +1.020 MPa -0.51 to +10.40 kgf/cm2 -0.50 to +10.20 bar -7.2 to +148.0 psi [DPH-L133] -0.17 to +3.57 MPa -1.7 to +36.4 kgf/cm2 -1.7 to +35.7 bar -24 to +518 psi [DPH-L114] -0.50 to +10.20 MPa -5.1 to +104.0 kgf/cm2 -5.0 to +102.0 bar -72 to +1480 psi [DPH-L154] -2.5 to +51.0 MPa -25 to +520 kgf/cm2 -25 to +510 bar -360 to +7400 psi (Note): Values differ depending on a connected sensor head. |
Supply Voltage | 12 to 24 V DC ±10 % Ripple P-P 10 % or less |
Power Consumption | Normal operation : 960 mW or less (Current consumption 40 mA or less at 24 V supply voltage) ECO mode (STD) : 720 mW or less (Current consumption 30 mA or less at 24 V supply voltage) ECO mode (FULL) : 600 mW or less (Current consumption 25 mA or less at 24 V supply voltage) Excluding the current consumption of sensor head and analog output current |
Comparative Output | PNP open-collector transistor (2 outputs) ・ Maximum source current : 50 mA ・ Applied voltage : 30 V DC or less (between comparative output and +V) ・ Residual voltage : 1 V or less (at 50 mA source current) |
Comparative Output: Output Operation | NO / NC, selectable by key operation |
Comparative Output: Output Modes | EASY mode / Hysteresis mode / Window comparator mode |
Comparative Output: Hysteresis | Minimum 1 digit (variable)(however, 2 digits when using psi unit) |
Comparative Output: Repeatability | Within ±0.2 % F.S. |
Comparative Output: Response Time | 5 ms, 10 ms, 25 ms, 50 ms, 100 ms, 250 ms, 500 ms, 1,000 ms, 5,000 ms, selectable by key operation |
Comparative Output: Short-Circuit Protection | Incorporated |
Analog Output | ・ Output current : 1 to 5 V DC ・ Zero point : within 1 V ±0.5 % F.S. (excluding DPH-L113V) within 1.364 V ±0.5 % F.S. (DPH-L113V) ・ Span : within 4 V ±0.5 % F.S. ・ Linearity : within ±0.1 % F.S. ・ Output impedance : 1 kΩ approx. ・ Output current : 4 to 20 mA ・ Zero point : within 4 mA ±1.0 % F.S. (excluding DPH-L113V) within 5.455 mA ±1.0 % F.S. (DPH-L113V) ・ Span : within 16 mA ±1.5 % F.S. ・ Linearity : within ±0.1 % F.S. ・ Load resistance : 250 Ω (max.) |
Inputs: Sensor Head Input | Input voltage range : 1 to 5 V DC (over rated pressure range) |
Inputs: External Input | ON voltage : 5 V to +V DC OFF voltage : 0.6 V DC or less, or open Input impedance : 10 kΩ approx. Input time : 1 ms or more |
Operation Indicator | Orange LED (Comparative output 1 operation indicator, comparative output 2 operation indicator : Lights up when each comparative output is ON ) |
Protection | IP40 (IEC) |
Ambient Temperature | -10 to +50 ℃ +14 to +122 ℉ (No dew condensation or icing allowed), Storage : -10 to +60 ℃ +14 to +140 ℉ |
Ambient Humidity | 35 to 85 % RH, Storage : 35 to 85 % RH |
Voltage Withstandability | 500 V AC for one min. between all supply terminals connected together and enclosure |
Insulation Resistance | 50 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure |
Vibration Resistance | 10 to 500 Hz frequency, amplitude 3 mm 0.118 in or maximum acceleration 196 m/s2, in X, Y and Z directions for two hours each (when panel mounting bracket is mounted : 10 to 150 Hz frequency, amplitude 0.75 mm 0.030 in or maximum acceleration 49 m/s2, in X, Y and Z directions for two hours each) |
Shock Resistance | 100 m/s2 acceleration in X, Y and Z directions for three times each |
Temperature Characteristics | Within ±0.5 % F.S. (ambient temperature range based on +20 ℃ +68 ℉) |
Material | Enclosure : PBT (glass fiber reinforced), LCD display : Acrylic, Mounting threaded part : Brass (nickel plated), Switch part : Silicone rubber |
Connecting Method | Connector |
Cable Length | Total length up to 100 m 328.1 ft (less than 30 m 98.4 ft when conforming to CE marking) is possible with 0.3 mm2, or more, cable. |
Weight (Typ.) | Net weight : 25 g approx. (excluding connector attached cable), Gross weight : 140 g approx. |
Accessories | Pressure unit label: 1 set |
Remark | Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 ℉. The values specified above are applied only to the controller. |
PIR Motion Sensors (PAPIRS)