Specification

Specifications table for model DPC-L101-P
ItemPerformance characteristics
CE Marking Directive ComplianceEMC Directive, RoHS Directive
Rated Pressure Range DPH-L113V : -0.1 to +1 MPa
DPH-L113 : 0 to +1 MPa
DPH-L133 : 0 to +3.5 MPa
DPH-L114 : 0 to +10 MPa
DPH-L154 : 0 to +50 MPa
(Note) : Values differ depending on a connected sensor head.
Set Pressure Range [DPH-L113V]
-1.177 to +1.177 MPa
-12.00 to +12.00 kgf/cm2
-11.77 to +11.77 bar
-170.6 to +170.6 psi
[DPH-L113]
-1.070 to +1.070 MPa
-10.91 to +10.91 kgf/cm2
-10.70 to +10.70 bar
-155.2 to +155.2 psi
[DPH-L133]
-3.74 to +3.74 MPa
-38.1 to +38.1 kgf/cm2
-37.4 to +37.4 bar
-542 to +542 psi
[DPH-L114]
-10.70 to +10.70 MPa
-109.1 to +109.1 kgf/cm2
-107.0 to +107.0 bar
-1552 to +1552 psi
[DPH-L154]
-53.5 to +53.5 MPa
-545 to +545 kgf/cm2
-535 to +535 bar
-1980 to +7760 psi
(Note) : Values differ depending on a connected sensor head.
Set Pressure ResolutionDPH-L113V : 0.001 MPa
DPH-L113 : 0.001 MPa
DPH-L133 : 0.01 MPa
DPH-L114 : 0.01 MPa
DPH-L154 : 0.1 MPa
(Note): Values differ depending on a connected sensor head.
Display4 digits +4 digits 3-color LCD display
(Display refresh rate : 250 ms, 500 ms, 1,000 ms, selectable by key operation)
Display: Displayable Pressure Range[DPH-L113V]
-0.155 to +1.022 MPa
-1.58 to +10.42 kgf/cm2
-1.55 to +10.22 bar
-22.4 to +148.2 psi
[DPH-L113]
-0.050 to +1.020 MPa
-0.51 to +10.40 kgf/cm2
-0.50 to +10.20 bar
-7.2 to +148.0 psi
[DPH-L133]
-0.17 to +3.57 MPa
-1.7 to +36.4 kgf/cm2
-1.7 to +35.7 bar
-24 to +518 psi
[DPH-L114]
-0.50 to +10.20 MPa
-5.1 to +104.0 kgf/cm2
-5.0 to +102.0 bar
-72 to +1480 psi
[DPH-L154]
-2.5 to +51.0 MPa
-25 to +520 kgf/cm2
-25 to +510 bar
-360 to +7400 psi
(Note): Values differ depending on a connected sensor head.
Supply Voltage 12 to 24 V DC ±10 % Ripple P-P 10 % or less
Power ConsumptionNormal operation : 960 mW or less (Current consumption 40 mA or less at 24 V supply voltage)
ECO mode (STD) : 720 mW or less (Current consumption 30 mA or less at 24 V supply voltage)
ECO mode (FULL) : 600 mW or less (Current consumption 25 mA or less at 24 V supply voltage)
Excluding the current consumption of sensor head and analog output current
Comparative Output
PNP open-collector transistor (2 outputs)
・ Maximum source current : 50 mA
・ Applied voltage : 30 V DC or less
(between comparative output and +V)
・ Residual voltage : 1 V or less (at 50 mA source current)
Comparative Output: Output OperationNO / NC, selectable by key operation
Comparative Output: Output ModesEASY mode / Hysteresis mode / Window comparator mode
Comparative Output: HysteresisMinimum 1 digit (variable)(however, 2 digits when using psi unit)
Comparative Output: RepeatabilityWithin ±0.2 % F.S.
Comparative Output: Response Time5 ms, 10 ms, 25 ms, 50 ms, 100 ms, 250 ms, 500 ms, 1,000 ms, 5,000 ms, selectable by key operation
Comparative Output: Short-Circuit ProtectionIncorporated
Analog Output
・ Output current : 1 to 5 V DC
・ Zero point : within 1 V ±0.5 % F.S. (excluding DPH-L113V) within 1.364 V ±0.5 % F.S. (DPH-L113V)
・ Span : within 4 V ±0.5 % F.S.
・ Linearity : within ±0.1 % F.S.
・ Output impedance : 1 kΩ approx.


・ Output current : 4 to 20 mA
・ Zero point : within 4 mA ±1.0 % F.S. (excluding DPH-L113V) within 5.455 mA ±1.0 % F.S. (DPH-L113V)
・ Span : within 16 mA ±1.5 % F.S.
・ Linearity : within ±0.1 % F.S.
・ Load resistance : 250 Ω (max.)
Inputs: Sensor Head Input Input voltage range : 1 to 5 V DC (over rated pressure range)
Inputs: External Input
ON voltage : 5 V to +V DC
OFF voltage : 0.6 V DC or less, or open
Input impedance : 10 kΩ approx.
Input time : 1 ms or more
Operation Indicator Orange LED
(Comparative output 1 operation indicator, comparative output 2 operation indicator : Lights up when each comparative output is ON )
ProtectionIP40 (IEC)
Ambient Temperature-10 to +50 ℃ +14 to +122 ℉ (No dew condensation or icing allowed), Storage : -10 to +60 ℃ +14 to +140 ℉
Ambient Humidity35 to 85 % RH, Storage : 35 to 85 % RH
Voltage Withstandability500 V AC for one min. between all supply terminals connected together and enclosure
Insulation Resistance50 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure
Vibration Resistance10 to 500 Hz frequency, double amplitude 3 mm 0.118 in or maximum acceleration 196 m/s2, in X, Y and Z directions for two hours each (when panel mounting bracket is mounted: 10 to 150 Hz frequency, double amplitude 0.75 mm 0.030 in or maximum acceleration 49 m/s2, in X, Y and Z directions for two hours each)
Shock Resistance100 m/s2 acceleration in X, Y and Z directions three times each
Temperature Characteristics Within ±0.5 % F.S. (ambient temperature range based on +20 ℃ +68 ℉)
MaterialEnclosure : PBT (glass fiber reinforced),
LCD display : Acrylic,
Mounting threaded part : Brass (nickel plated),
Switch part : Silicone rubber
Connecting MethodConnector
Cable LengthTotal length up to 100 m 328.084 ft (less than 30 m 98.425 ft when conforming to CE marking) is possible with 0.3 mm2, or more, cable.
Weight (Typ.)Net weight : 25 g approx. (excluding connector attached cable),
Gross weight : 140 g approx.
AccessoriesCN-66A-C2 (Connector attached cable 2 m 6.562 ft), Pressure unit label: 1 set
RemarkWhere measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 ℉.
The values specified above are applied only to the controller.
DummyCE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations)