| | Specular reflective | 10 mm 0.394 in | plus or minus 1 mm plus or minus 0.039 in (Note) Measuring range at sampling periods of 20 micro s and 10 micro s is as follows. 20 micro s: +0.1 to +1.0 mm +0.004 to +0.039 in 10 micro s: +0.8 to +1.0 mm +0.032 to +0.039 in | 0.04 micro m 0.0016 mil [256] 0.01 micro m 0.0004 mil [4,096] (Note) The P-P value for the deviation in the digital measurement values at the measurement center range has been converted for the measurement center distance. | plus or minus 0.02 % F.S. (Note) Indicates error with respect to the ideal linear values for digital displacement output when standard objects were measured by our company. It may vary depending on the types of objects being measured. | 0.01 % F.S./degrees | Red semiconductor laser (Peak emission wavelength: 658 nm 0.026 mil) Class 1 (IEC / JIS / FDA, Laser Notice No.50), Max. output: 0.1 mW | 20 x 700 micro m 0.787 x 27.559 mil approx. (Note) This beam diameter is the size at the measurement center distance. These values were defined by using 1/e2 (13.5 %) of the center light intensity. If there is a slight leakage of light outside the normal spot diameter and if the periphery surrounding the sensing point has a higher reflectivity than the sensing point itself, then the results may be affected. | Linear image sensor | Green LED (lights up during laser emission) | Yellow LED (lights up when near the measurement center distance, blinks when within the measuring range, and lights out when outside of the measuring range.) | IP67 (IEC) (excluding the connector) | 0 to +45 degrees +32 to +113 degrees Fahrenheit (No dew condensation), Storage: -20 to +70 degrees -4 to +158 degrees Fahrenheit | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 3,000 liter x at the light-receiving face | 10 to 55 Hz (period: 1 min.) frequency, 1.5 mm 0.059 in amplitude in X,Y and Z directions for two hours each | 196 m/s2 acceleration (20 G approx.) in X,Y and Z directions for three times each | Cabtyre cable, 0.5 m 1.640 ft long with connector | Extension up to total 30 m 98.425 ft is possible, with optional cable. | Enclosure: Die-cast aluminum Case cover: Die-cast aluminum Front cover: Glass | 250 g approx. (including cable) | English warning label: 1 set [The FDA regulations conforming type includes a set of both the IEC label (written in English) and JIS label (written in Japanese)]. |
| | Specular reflective | 10 mm 0.394 in | plus or minus 1 mm plus or minus 0.039 in (Note) Measuring range at sampling periods of 20 micro s and 10 micro s is as follows. 20 micro s: +0.1 to +1.0 mm +0.004 to +0.039 in 10 micro s: +0.8 to +1.0 mm +0.032 to +0.039 in | 0.25 micro m 0.010 mil [256] (Note) The P-P value for the deviation in the digital measurement values at the measurement center range has been converted for the measurement center distance. | plus or minus 0.02 % F.S. (Note) Indicates error with respect to the ideal linear values for digital displacement output when standard objects were measured by our company. It may vary depending on the types of objects being measured. | 0.01 % F.S./degrees | Red semiconductor laser (Peak emission wavelength: 658 nm 0.026 mil) Class 1 (IEC / JIS / FDA, Laser Notice No.50), Max. output: 0.1 mW | 20 x 700 micro m 0.787 x 27.559 mil approx. (Note) This beam diameter is the size at the measurement center distance. These values were defined by using 1/e2 (13.5 %) of the center light intensity. If there is a slight leakage of light outside the normal spot diameter and if the periphery surrounding the sensing point has a higher reflectivity than the sensing point itself, then the results may be affected. | Linear image sensor | Green LED (lights up during laser emission) | Yellow LED (lights up when near the measurement center distance, blinks when within the measuring range, and lights out when outside of the measuring range.) | IP67 (IEC) (excluding the connector) | 0 to +45 degrees +32 to +113 degrees Fahrenheit (No dew condensation), Storage: -20 to +70 degrees -4 to +158 degrees Fahrenheit | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 3,000 liter x at the light-receiving face | 10 to 55 Hz (period: 1 min.) frequency, 1.5 mm 0.059 in amplitude in X,Y and Z directions for two hours each | 196 m/s2 acceleration (20 G approx.) in X,Y and Z directions for three times each | Cabtyre cable, 0.5 m 1.640 ft long with connector | Extension up to total 30 m 98.425 ft is possible, with optional cable. | Enclosure: Die-cast aluminum Case cover: Die-cast aluminum Front cover: Glass | 250 g approx. (including cable) | English warning label: 1 set [The FDA regulations conforming type includes a set of both the IEC label (written in English) and JIS label (written in Japanese)]. |
| | Diffuse reflective Specular reflective | Diffuse reflective: 30 mm 1.181 in Specular reflective: 26.4 mm 1.039 in | Diffuse reflective: plus or minus 5 mm plus or minus 0.197 in Specular reflective: plus or minus 4.6 mm plus or minus 0.181 in (Note) Measuring range at sampling periods of 20 micro s and 10 micro s is as follows. [Diffuse reflective] 20 micro s: 0 to +5.0 mm 0 to +0.197 in 10 micro s: +3.8 to +5.0 mm +0.150 to +0.197 in [Specular reflective] 20 micro s: 0 to +4.6 mm 0 to +0.181 in 10 micro s: +3.6 to +4.6 mm +0.142 to +0.181 in | 0.1 micro m 0.004 mil [256] 0.025 micro m 0.001 mil [4,096] (Note) The P-P value for the deviation in the digital measurement values at the measurement center range has been converted for the measurement center distance. | plus or minus 0.03 % F.S. (Note) Indicates error with respect to the ideal linear values for digital displacement output when standard objects were measured by our company. It may vary depending on the types of objects being measured. | 0.01 % F.S./degrees | Red semiconductor laser (Peak emission wavelength: 658 nm 0.026 mil) Class 2 (IEC / JIS), Class II (FDA) Max. output: 1 mW | 30 x 1,200 micro m 1.181 x 47.244 mil approx. (Note) This beam diameter is the size at the measurement center distance. These values were defined by using 1/e2 (13.5 %) of the center light intensity. If there is a slight leakage of light outside the normal spot diameter and if the periphery surrounding the sensing point has a higher reflectivity than the sensing point itself, then the results may be affected. | Linear image sensor | Green LED (lights up during laser emission) | Yellow LED (lights up when near the measurement center distance, blinks when within the measuring range, and lights out when outside of the measuring range.) | IP67 (IEC) (excluding the connector) | 0 to +45 degrees +32 to +113 degrees Fahrenheit (No dew condensation), Storage: -20 to +70 degrees -4 to +158 degrees Fahrenheit | 35 to 85 % RH, Storage: 35 to 85 % RH | Incandescent light: 3,000 liter x at the light-receiving face | 10 to 55 Hz (period: 1 min.) frequency, 1.5 mm 0.059 in amplitude in X,Y and Z directions for two hours each | 196 m/s2 acceleration (20 G approx.) in X,Y and Z directions for three times each | Cabtyre cable, 0.5 m 1.640 ft long with connector | Extension up to total 30 m 98.425 ft is possible, with optional cable. | Enclosure: Die-cast aluminum Case cover: Die-cast aluminum Front cover: Glass | 250 g approx. (including cable) | English warning label: 1 set [The FDA regulations conforming type includes a set of both the IEC label (written in English) and JIS label (written in Japanese)]. |