Single side stable
5 V DC
1 Form A
Sockets are available.
Sealed
PC board terminal
200 mW
70%V or less of rated coil voltage (Initial)
10%V or more of rated coil voltage (Initial)
250 V AC, 125 V DC (0.2 A)
10 A (AC, DC)
10 mA 5 V DC
Au-flashed AgSnO2 type
Min. 50x106 ope. (switching frequency: at 300 times/min)
Min. 1x105
1,000 Vrms for 1 min (detection current: 10 mA)
4,000 Vrms for 1 min (detection current: 10 mA)
Ambient temperature: –40 to +70°C Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
[Between input and output] 6 mm
Carton
50
500
Max. 70% V of rated coil voltage (Initial)
Min. 10% V of rated coil voltage (Initial)
40 mA
125 Ω
130% V of rated coil voltage
Max. 30 mΩ (by voltage drop 6 V DC 1 A)
10 A 250 V AC, 10 A 30 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
10,000 V
Max. 10 ms at rated coil voltage (without bounce)
Max. 8 ms at rated coil voltage (without bounce, without diode)
98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs)
980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 1.5 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 3 mm)
Approx. 6 g
Ambient temperature: -40 to +70℃ Humidity: 5 to 85% RH (Avoid icing and condensation)
[switching frequency: 20 times/min] Min. 100x103 ope. 10 A 250 V AC Min. 100x103 ope. 10 A 30 V DC
2,500 VA, 300 W
Single side stable
12 V DC
1 Form A
Sockets are available.
Sealed
PC board terminal
200 mW
70%V or less of rated coil voltage (Initial)
10%V or more of rated coil voltage (Initial)
250 V AC, 125 V DC (0.2 A)
10 A (AC, DC)
10 mA 5 V DC
Au-flashed AgSnO2 type
Min. 50x106 ope. (switching frequency: at 300 times/min)
Min. 1x105
1,000 Vrms for 1 min (detection current: 10 mA)
4,000 Vrms for 1 min (detection current: 10 mA)
Ambient temperature: –40 to +70°C Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
[Between input and output] 6 mm
Carton
50
500
Max. 70% V of rated coil voltage (Initial)
Min. 10% V of rated coil voltage (Initial)
16.6 mA
720 Ω
130% V of rated coil voltage
Max. 30 mΩ (by voltage drop 6 V DC 1 A)
10 A 250 V AC, 10 A 30 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
10,000 V
Max. 10 ms at rated coil voltage (without bounce)
Max. 8 ms at rated coil voltage (without bounce, without diode)
98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs)
980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 1.5 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 3 mm)
Approx. 6 g
Ambient temperature: -40 to +70℃ Humidity: 5 to 85% RH (Avoid icing and condensation)
[switching frequency: 20 times/min] Min. 100x103 ope. 10 A 250 V AC Min. 100x103 ope. 10 A 30 V DC
2,500 VA, 300 W
Single side stable
6 V DC
1 Form A
Sockets are available.
Sealed
PC board terminal
200 mW
70%V or less of rated coil voltage (Initial)
10%V or more of rated coil voltage (Initial)
250 V AC, 125 V DC (0.2 A)
10 A (AC, DC)
10 mA 5 V DC
Au-flashed AgSnO2 type
Min. 50x106 ope. (switching frequency: at 300 times/min)
Min. 1x105
1,000 Vrms for 1 min (detection current: 10 mA)
4,000 Vrms for 1 min (detection current: 10 mA)
Ambient temperature: –40 to +70°C Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
[Between input and output] 6 mm
Carton
50
500
Max. 70% V of rated coil voltage (Initial)
Min. 10% V of rated coil voltage (Initial)
33.3 mA
180 Ω
130% V of rated coil voltage
Max. 30 mΩ (by voltage drop 6 V DC 1 A)
10 A 250 V AC, 10 A 30 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
10,000 V
Max. 10 ms at rated coil voltage (without bounce)
Max. 8 ms at rated coil voltage (without bounce, without diode)
98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs)
980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 1.5 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 3 mm)
Approx. 6 g
Ambient temperature: -40 to +70℃ Humidity: 5 to 85% RH (Avoid icing and condensation)
[switching frequency: 20 times/min] Min. 100x103 ope. 10 A 250 V AC Min. 100x103 ope. 10 A 30 V DC
2,500 VA, 300 W
2 coil latching
12 V DC
1 Form A
Sockets are available.
Sealed
PC board terminal
200 mW
250 V AC, 125 V DC (0.2 A)
10 A (AC, DC)
10 mA 5 V DC
Au-flashed AgSnO2 type
Min. 50x106 ope. (switching frequency: at 300 times/min)
Min. 1x105
1,000 Vrms for 1 min (detection current: 10 mA)
4,000 Vrms for 1 min (detection current: 10 mA)
Ambient temperature: –40 to +70°C Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Max. 70% V of rated coil voltage (Initial)
Max. 70% V of rated coil voltage (Initial)
[Between input and output] 6 mm
Carton
50
500
Set coil: 16.6 mA Reset coil: 16.6 mA
Set coil: 720 Ω Reset coil: 720 Ω
130% V of rated coil voltage
Max. 30 mΩ (by voltage drop 6 V DC 1 A)
10 A 250 V AC, 10 A 30 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
10,000 V
98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs)
980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 1.5 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 3 mm)
Approx. 6 g
Ambient temperature: -40 to +70℃ Humidity: 5 to 85% RH (Avoid icing and condensation)
[switching frequency: 20 times/min] Min. 100x103 ope. 10 A 250 V AC Min. 100x103 ope. 10 A 30 V DC
Max. 10 ms at rated coil voltage (without bounce)
Max. 10 ms at rated coil voltage (without bounce, without diode)
2,500 VA, 300 W
2 coil latching
6 V DC
1 Form A
Sockets are available.
Sealed
PC board terminal
200 mW
250 V AC, 125 V DC (0.2 A)
10 A (AC, DC)
10 mA 5 V DC
Au-flashed AgSnO2 type
Min. 50x106 ope. (switching frequency: at 300 times/min)
Min. 1x105
1,000 Vrms for 1 min (detection current: 10 mA)
4,000 Vrms for 1 min (detection current: 10 mA)
Ambient temperature: –40 to +70°C Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Max. 70% V of rated coil voltage (Initial)
Max. 70% V of rated coil voltage (Initial)
[Between input and output] 6 mm
Carton
50
500
Set coil: 33.3 mA Reset coil: 33.3 mA
Set coil: 180 Ω Reset coil: 180 Ω
130% V of rated coil voltage
Max. 30 mΩ (by voltage drop 6 V DC 1 A)
10 A 250 V AC, 10 A 30 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
10,000 V
98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs)
980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 1.5 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 3 mm)
Approx. 6 g
Ambient temperature: -40 to +70℃ Humidity: 5 to 85% RH (Avoid icing and condensation)
[switching frequency: 20 times/min] Min. 100x103 ope. 10 A 250 V AC Min. 100x103 ope. 10 A 30 V DC
Max. 10 ms at rated coil voltage (without bounce)
Max. 10 ms at rated coil voltage (without bounce, without diode)
2,500 VA, 300 W
2 coil latching
24 V DC
1 Form A
Sockets are available.
Sealed
PC board terminal
200 mW
250 V AC, 125 V DC (0.2 A)
10 A (AC, DC)
10 mA 5 V DC
Au-flashed AgSnO2 type
Min. 50x106 ope. (switching frequency: at 300 times/min)
Min. 1x105
1,000 Vrms for 1 min (detection current: 10 mA)
4,000 Vrms for 1 min (detection current: 10 mA)
Ambient temperature: –40 to +70°C Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Max. 70% V of rated coil voltage (Initial)
Max. 70% V of rated coil voltage (Initial)
[Between input and output] 6 mm
Carton
50
500
Set coil: 8.3 mA Reset coil: 8.3 mA
Set coil: 2,880 Ω Reset coil: 2,880 Ω
130% V of rated coil voltage
Max. 30 mΩ (by voltage drop 6 V DC 1 A)
10 A 250 V AC, 10 A 30 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
10,000 V
98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs)
980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 1.5 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 3 mm)
Approx. 6 g
Ambient temperature: -40 to +70℃ Humidity: 5 to 85% RH (Avoid icing and condensation)
[switching frequency: 20 times/min] Min. 100x103 ope. 10 A 250 V AC Min. 100x103 ope. 10 A 30 V DC
Max. 10 ms at rated coil voltage (without bounce)
Max. 10 ms at rated coil voltage (without bounce, without diode)
2,500 VA, 300 W
Single side stable
12 V DC
1 Form A 1 Form B
Sockets are available.
Sealed
PC board terminal
200 mW
70%V or less of rated coil voltage (Initial)
10%V or more of rated coil voltage (Initial)
250 V AC, 125 V DC (0.2 A)
8 A (AC, DC)
10 mA 5 V DC
Au-flashed AgSnO2 type
Min. 50x106 ope. (switching frequency: at 300 times/min)
Min. 1x105
1,000 Vrms for 1 min (detection current: 10 mA)
4,000 Vrms for 1 min (detection current: 10 mA)
Ambient temperature: –40 to +70°C Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
[Between input and output] 6 mm
Carton
50
500
Max. 70% V of rated coil voltage (Initial)
Min. 10% V of rated coil voltage (Initial)
16.6 mA
720 Ω
130% V of rated coil voltage
Max. 30 mΩ (by voltage drop 6 V DC 1 A)
8 A 250 V AC, 8 A 30 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
10,000 V
Max. 10 ms at rated coil voltage (without bounce)
Max. 8 ms at rated coil voltage (without bounce, without diode)
98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs)
980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 1.5 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 3 mm)
Approx. 6 g
Ambient temperature: -40 to +70℃ Humidity: 5 to 85% RH (Avoid icing and condensation)
[switching frequency: 20 times/min] Min. 100x103 ope. 8 A 250 V AC Min. 100x103 ope. 8 A 30 V DC
4,000 Vrms for 1 min
2,000 VA, 240 W
Single side stable
5 V DC
1 Form A 1 Form B
Sockets are available.
Sealed
PC board terminal
200 mW
70%V or less of rated coil voltage (Initial)
10%V or more of rated coil voltage (Initial)
250 V AC, 125 V DC (0.2 A)
8 A (AC, DC)
10 mA 5 V DC
Au-flashed AgSnO2 type
Min. 50x106 ope. (switching frequency: at 300 times/min)
Min. 1x105
1,000 Vrms for 1 min (detection current: 10 mA)
4,000 Vrms for 1 min (detection current: 10 mA)
Ambient temperature: –40 to +70°C Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
[Between input and output] 6 mm
Carton
50
500
Max. 70% V of rated coil voltage (Initial)
Min. 10% V of rated coil voltage (Initial)
40 mA
125 Ω
130% V of rated coil voltage
Max. 30 mΩ (by voltage drop 6 V DC 1 A)
8 A 250 V AC, 8 A 30 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
10,000 V
Max. 10 ms at rated coil voltage (without bounce)
Max. 8 ms at rated coil voltage (without bounce, without diode)
98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs)
980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 1.5 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 3 mm)
Approx. 6 g
Ambient temperature: -40 to +70℃ Humidity: 5 to 85% RH (Avoid icing and condensation)
[switching frequency: 20 times/min] Min. 100x103 ope. 8 A 250 V AC Min. 100x103 ope. 8 A 30 V DC
4,000 Vrms for 1 min
2,000 VA, 240 W
Single side stable
24 V DC
1 Form A 1 Form B
Sockets are available.
Sealed
PC board terminal
200 mW
70%V or less of rated coil voltage (Initial)
10%V or more of rated coil voltage (Initial)
250 V AC, 125 V DC (0.2 A)
8 A (AC, DC)
10 mA 5 V DC
Au-flashed AgSnO2 type
Min. 50x106 ope. (switching frequency: at 300 times/min)
Min. 1x105
1,000 Vrms for 1 min (detection current: 10 mA)
4,000 Vrms for 1 min (detection current: 10 mA)
Ambient temperature: –40 to +70°C Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
[Between input and output] 6 mm
Carton
50
500
Max. 70% V of rated coil voltage (Initial)
Min. 10% V of rated coil voltage (Initial)
8.3 mA
2,880 Ω
130% V of rated coil voltage
Max. 30 mΩ (by voltage drop 6 V DC 1 A)
8 A 250 V AC, 8 A 30 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
10,000 V
Max. 10 ms at rated coil voltage (without bounce)
Max. 8 ms at rated coil voltage (without bounce, without diode)
98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs)
980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 1.5 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 3 mm)
Approx. 6 g
Ambient temperature: -40 to +70℃ Humidity: 5 to 85% RH (Avoid icing and condensation)
[switching frequency: 20 times/min] Min. 100x103 ope. 8 A 250 V AC Min. 100x103 ope. 8 A 30 V DC
4,000 Vrms for 1 min
2,000 VA, 240 W
Single side stable
6 V DC
1 Form A 1 Form B
Sockets are available.
Sealed
PC board terminal
200 mW
70%V or less of rated coil voltage (Initial)
10%V or more of rated coil voltage (Initial)
250 V AC, 125 V DC (0.2 A)
8 A (AC, DC)
10 mA 5 V DC
Au-flashed AgSnO2 type
Min. 50x106 ope. (switching frequency: at 300 times/min)
Min. 1x105
1,000 Vrms for 1 min (detection current: 10 mA)
4,000 Vrms for 1 min (detection current: 10 mA)
Ambient temperature: –40 to +70°C Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
[Between input and output] 6 mm
Carton
50
500
Max. 70% V of rated coil voltage (Initial)
Min. 10% V of rated coil voltage (Initial)
33.3 mA
180 Ω
130% V of rated coil voltage
Max. 30 mΩ (by voltage drop 6 V DC 1 A)
8 A 250 V AC, 8 A 30 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
10,000 V
Max. 10 ms at rated coil voltage (without bounce)
Max. 8 ms at rated coil voltage (without bounce, without diode)
98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs)
980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 1.5 mm, detection time: 10 μs)
10 to 55 Hz (at double amplitude of 3 mm)
Approx. 6 g
Ambient temperature: -40 to +70℃ Humidity: 5 to 85% RH (Avoid icing and condensation)
[switching frequency: 20 times/min] Min. 100x103 ope. 8 A 250 V AC Min. 100x103 ope. 8 A 30 V DC
4,000 Vrms for 1 min
2,000 VA, 240 W