Panasonic’s DY Series Polarized Power Relays are characterized by a high capacity of 1 Form A (10A 250V AC), 1 Form A 1 Form B (8A 250V AC), and long insulation distance generated by reinforced insulation with 6 mm distance between input and output. The DY Series Relays are ideal for various applications, including control for industrial machines, output relays for temperature, measuring and security equipment.

Features:

  • High Capacity
  • Long Insulation Distance
  • Variety of Contact Arrangements: Wide Lineup of 1 Form A, 1 Form A 1 Form B
  • Sockets and Latching Types Available

Part Number List

Results 24
Models table for series DY Series Relays
Part No.DatasheetOperating Function Rated Coil VoltageContact ArrangementAccessoriesProtective ConstructionTerminal TypeRated Operating Power Pick-Up VoltageDrop-Out VoltageMax. Switching VoltageMax. Switching CurrentMin. Switching Load (Reference Value) Contact MaterialMechanical LifeElectrical LifeDielectric Strength (Initial): Between Open ContactsDielectric Strength (Initial): Between Contact and CoilAmbient TemperatureSet Voltage Reset VoltageInsulation DistancePacking QuantityPacking Quantity; Inner Carton (Pcs.) Packing Quantity; Outer Carton (Pcs.)Operate Voltage (@20oC)Release Voltage (at20°C) Rated Operating Current [±10%] (at 20°C)Resistance [±10%] (at 20°C) Max. Allowable Voltage (at 20°C 68°F)Contact Resistance (Initial)Contact Rating (Resistive Load)Insulation Resistance (Initial)Surge Withstand Voltage (Initial): Between Contact and CoilOperate Time (Initial) (At 20oC)Hock Resistance (Functional)Release Time (Initial) (at 20°C) Hock Resistance (Destructive)Vibration Resistance (Functional) Vibration Resistance (Destructive)Weight (Typ.)ConditionsResistive LoadTime (Initial) (at 20°C 68°F) (Initial) Reset Time (Initial) (at20°C 68°F) Dielectric Strength (Initial): Between Contact SetsMax. Switching Power (Resistive Load)
2 coil latching
12 V DC
1 Form A
Sockets are available.
Sealed
PC board terminal
200 mW
250 V AC, 125 V DC (0.2 A)
10 A (AC, DC)
10 mA 5 V DC
Au-flashed AgSnO2 type
Min. 50x106 ope. (switching frequency: at 300 times/min)
Min. 1x105
1,000 Vrms for 1 min (detection current: 10 mA)
4,000 Vrms for 1 min (detection current: 10 mA)
Ambient temperature: –40 to +70°C
Humidity: 5 to 85% R.H.
(Not freezing and condensing at low temperature)
Max. 70% V of rated coil voltage (Initial)
Max. 70% V of rated coil voltage (Initial)
[Between input and output]
6 mm
Carton
50
500
Set coil: 16.6 mA
Reset coil: 16.6 mA
Set coil: 720 Ω
Reset coil: 720 Ω
130% V of rated coil voltage
Max. 30 mΩ (by voltage drop 6 V DC 1 A)
10 A 250 V AC, 10 A 30 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
10,000 V
98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs)
980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 1.5 mm, detection time: 10 µs)
10 to 55 Hz (at double amplitude of 3 mm)
Approx. 6 g
Ambient temperature: -40 to +70°C
Humidity: 5 to 85% RH (Avoid icing and condensation)
[switching frequency: 20 times/min]
Min. 100x103 ope. 10 A 250 V AC
Min. 100x103 ope. 10 A 30 V DC
Max. 10 ms at rated coil voltage (without bounce)
Max. 10 ms at rated coil voltage (without bounce, without diode)
2,500 VA, 300 W
2 coil latching
24 V DC
1 Form A
Sockets are available.
Sealed
PC board terminal
200 mW
250 V AC, 125 V DC (0.2 A)
10 A (AC, DC)
10 mA 5 V DC
Au-flashed AgSnO2 type
Min. 50x106 ope. (switching frequency: at 300 times/min)
Min. 1x105
1,000 Vrms for 1 min (detection current: 10 mA)
4,000 Vrms for 1 min (detection current: 10 mA)
Ambient temperature: –40 to +70°C
Humidity: 5 to 85% R.H.
(Not freezing and condensing at low temperature)
Max. 70% V of rated coil voltage (Initial)
Max. 70% V of rated coil voltage (Initial)
[Between input and output]
6 mm
Carton
50
500
Set coil: 8.3 mA
Reset coil: 8.3 mA
Set coil: 2,880 Ω
Reset coil: 2,880 Ω
130% V of rated coil voltage
Max. 30 mΩ (by voltage drop 6 V DC 1 A)
10 A 250 V AC, 10 A 30 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
10,000 V
98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs)
980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 1.5 mm, detection time: 10 µs)
10 to 55 Hz (at double amplitude of 3 mm)
Approx. 6 g
Ambient temperature: -40 to +70°C
Humidity: 5 to 85% RH (Avoid icing and condensation)
[switching frequency: 20 times/min]
Min. 100x103 ope. 10 A 250 V AC
Min. 100x103 ope. 10 A 30 V DC
Max. 10 ms at rated coil voltage (without bounce)
Max. 10 ms at rated coil voltage (without bounce, without diode)
2,500 VA, 300 W
Single side stable
5 V DC
1 Form A 1 Form B
Sockets are available.
Sealed
PC board terminal
200 mW
70%V or less of rated coil voltage (Initial)
10%V or more of rated coil voltage (Initial)
250 V AC, 125 V DC (0.2 A)
8 A (AC, DC)
10 mA 5 V DC
Au-flashed AgSnO2 type
Min. 50x106 ope. (switching frequency: at 300 times/min)
Min. 1x105
1,000 Vrms for 1 min (detection current: 10 mA)
4,000 Vrms for 1 min (detection current: 10 mA)
Ambient temperature: –40 to +70°C
Humidity: 5 to 85% R.H.
(Not freezing and condensing at low temperature)
[Between input and output]
6 mm
Carton
50
500
Max. 70% V of rated coil voltage (Initial)
Min. 10% V of rated coil voltage (Initial)
40 mA
125 Ω
130% V of rated coil voltage
Max. 30 mΩ (by voltage drop 6 V DC 1 A)
8 A 250 V AC, 8 A 30 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
10,000 V
Max. 10 ms at rated coil voltage (without bounce)
98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs)
Max. 8 ms at rated coil voltage (without bounce, without diode)
980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 1.5 mm, detection time: 10 µs)
10 to 55 Hz (at double amplitude of 3 mm)
Approx. 6 g
Ambient temperature: -40 to +70°C
Humidity: 5 to 85% RH (Avoid icing and condensation)
[switching frequency: 20 times/min]
Min. 100x103 ope. 8 A 250 V AC
Min. 100x103 ope. 8 A 30 V DC
4,000 Vrms for 1 min
2,000 VA, 240 W
Single side stable
5 V DC
1 Form A
Sockets are available.
Sealed
PC board terminal
200 mW
70%V or less of rated coil voltage (Initial)
10%V or more of rated coil voltage (Initial)
250 V AC, 125 V DC (0.2 A)
10 A (AC, DC)
10 mA 5 V DC
Au-flashed AgSnO2 type
Min. 50x106 ope. (switching frequency: at 300 times/min)
Min. 1x105
1,000 Vrms for 1 min (detection current: 10 mA)
4,000 Vrms for 1 min (detection current: 10 mA)
Ambient temperature: –40 to +70°C
Humidity: 5 to 85% R.H.
(Not freezing and condensing at low temperature)
[Between input and output]
6 mm
Carton
50
500
Max. 70% V of rated coil voltage (Initial)
Min. 10% V of rated coil voltage (Initial)
40 mA
125 Ω
130% V of rated coil voltage
Max. 30 mΩ (by voltage drop 6 V DC 1 A)
10 A 250 V AC, 10 A 30 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
10,000 V
Max. 10 ms at rated coil voltage (without bounce)
98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs)
Max. 8 ms at rated coil voltage (without bounce, without diode)
980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 1.5 mm, detection time: 10 µs)
10 to 55 Hz (at double amplitude of 3 mm)
Approx. 6 g
Ambient temperature: -40 to +70°C
Humidity: 5 to 85% RH (Avoid icing and condensation)
[switching frequency: 20 times/min]
Min. 100x103 ope. 10 A 250 V AC
Min. 100x103 ope. 10 A 30 V DC
2,500 VA, 300 W
Single side stable
12 V DC
1 Form A
Sockets are available.
Sealed
PC board terminal
200 mW
70%V or less of rated coil voltage (Initial)
10%V or more of rated coil voltage (Initial)
250 V AC, 125 V DC (0.2 A)
10 A (AC, DC)
10 mA 5 V DC
Au-flashed AgSnO2 type
Min. 50x106 ope. (switching frequency: at 300 times/min)
Min. 1x105
1,000 Vrms for 1 min (detection current: 10 mA)
4,000 Vrms for 1 min (detection current: 10 mA)
Ambient temperature: –40 to +70°C
Humidity: 5 to 85% R.H.
(Not freezing and condensing at low temperature)
[Between input and output]
6 mm
Carton
50
500
Max. 70% V of rated coil voltage (Initial)
Min. 10% V of rated coil voltage (Initial)
16.6 mA
720 Ω
130% V of rated coil voltage
Max. 30 mΩ (by voltage drop 6 V DC 1 A)
10 A 250 V AC, 10 A 30 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
10,000 V
Max. 10 ms at rated coil voltage (without bounce)
98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs)
Max. 8 ms at rated coil voltage (without bounce, without diode)
980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 1.5 mm, detection time: 10 µs)
10 to 55 Hz (at double amplitude of 3 mm)
Approx. 6 g
Ambient temperature: -40 to +70°C
Humidity: 5 to 85% RH (Avoid icing and condensation)
[switching frequency: 20 times/min]
Min. 100x103 ope. 10 A 250 V AC
Min. 100x103 ope. 10 A 30 V DC
2,500 VA, 300 W
Single side stable
6 V DC
1 Form A
Sockets are available.
Sealed
PC board terminal
200 mW
70%V or less of rated coil voltage (Initial)
10%V or more of rated coil voltage (Initial)
250 V AC, 125 V DC (0.2 A)
10 A (AC, DC)
10 mA 5 V DC
Au-flashed AgSnO2 type
Min. 50x106 ope. (switching frequency: at 300 times/min)
Min. 1x105
1,000 Vrms for 1 min (detection current: 10 mA)
4,000 Vrms for 1 min (detection current: 10 mA)
Ambient temperature: –40 to +70°C
Humidity: 5 to 85% R.H.
(Not freezing and condensing at low temperature)
[Between input and output]
6 mm
Carton
50
500
Max. 70% V of rated coil voltage (Initial)
Min. 10% V of rated coil voltage (Initial)
33.3 mA
180 Ω
130% V of rated coil voltage
Max. 30 mΩ (by voltage drop 6 V DC 1 A)
10 A 250 V AC, 10 A 30 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
10,000 V
Max. 10 ms at rated coil voltage (without bounce)
98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs)
Max. 8 ms at rated coil voltage (without bounce, without diode)
980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 1.5 mm, detection time: 10 µs)
10 to 55 Hz (at double amplitude of 3 mm)
Approx. 6 g
Ambient temperature: -40 to +70°C
Humidity: 5 to 85% RH (Avoid icing and condensation)
[switching frequency: 20 times/min]
Min. 100x103 ope. 10 A 250 V AC
Min. 100x103 ope. 10 A 30 V DC
2,500 VA, 300 W
2 coil latching
6 V DC
1 Form A
Sockets are available.
Sealed
PC board terminal
200 mW
250 V AC, 125 V DC (0.2 A)
10 A (AC, DC)
10 mA 5 V DC
Au-flashed AgSnO2 type
Min. 50x106 ope. (switching frequency: at 300 times/min)
Min. 1x105
1,000 Vrms for 1 min (detection current: 10 mA)
4,000 Vrms for 1 min (detection current: 10 mA)
Ambient temperature: –40 to +70°C
Humidity: 5 to 85% R.H.
(Not freezing and condensing at low temperature)
Max. 70% V of rated coil voltage (Initial)
Max. 70% V of rated coil voltage (Initial)
[Between input and output]
6 mm
Carton
50
500
Set coil: 33.3 mA
Reset coil: 33.3 mA
Set coil: 180 Ω
Reset coil: 180 Ω
130% V of rated coil voltage
Max. 30 mΩ (by voltage drop 6 V DC 1 A)
10 A 250 V AC, 10 A 30 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
10,000 V
98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs)
980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 1.5 mm, detection time: 10 µs)
10 to 55 Hz (at double amplitude of 3 mm)
Approx. 6 g
Ambient temperature: -40 to +70°C
Humidity: 5 to 85% RH (Avoid icing and condensation)
[switching frequency: 20 times/min]
Min. 100x103 ope. 10 A 250 V AC
Min. 100x103 ope. 10 A 30 V DC
Max. 10 ms at rated coil voltage (without bounce)
Max. 10 ms at rated coil voltage (without bounce, without diode)
2,500 VA, 300 W
Single side stable
12 V DC
1 Form A 1 Form B
Sockets are available.
Sealed
PC board terminal
200 mW
70%V or less of rated coil voltage (Initial)
10%V or more of rated coil voltage (Initial)
250 V AC, 125 V DC (0.2 A)
8 A (AC, DC)
10 mA 5 V DC
Au-flashed AgSnO2 type
Min. 50x106 ope. (switching frequency: at 300 times/min)
Min. 1x105
1,000 Vrms for 1 min (detection current: 10 mA)
4,000 Vrms for 1 min (detection current: 10 mA)
Ambient temperature: –40 to +70°C
Humidity: 5 to 85% R.H.
(Not freezing and condensing at low temperature)
[Between input and output]
6 mm
Carton
50
500
Max. 70% V of rated coil voltage (Initial)
Min. 10% V of rated coil voltage (Initial)
16.6 mA
720 Ω
130% V of rated coil voltage
Max. 30 mΩ (by voltage drop 6 V DC 1 A)
8 A 250 V AC, 8 A 30 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
10,000 V
Max. 10 ms at rated coil voltage (without bounce)
98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs)
Max. 8 ms at rated coil voltage (without bounce, without diode)
980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 1.5 mm, detection time: 10 µs)
10 to 55 Hz (at double amplitude of 3 mm)
Approx. 6 g
Ambient temperature: -40 to +70°C
Humidity: 5 to 85% RH (Avoid icing and condensation)
[switching frequency: 20 times/min]
Min. 100x103 ope. 8 A 250 V AC
Min. 100x103 ope. 8 A 30 V DC
4,000 Vrms for 1 min
2,000 VA, 240 W
Single side stable
24 V DC
1 Form A 1 Form B
Sockets are available.
Sealed
PC board terminal
200 mW
70%V or less of rated coil voltage (Initial)
10%V or more of rated coil voltage (Initial)
250 V AC, 125 V DC (0.2 A)
8 A (AC, DC)
10 mA 5 V DC
Au-flashed AgSnO2 type
Min. 50x106 ope. (switching frequency: at 300 times/min)
Min. 1x105
1,000 Vrms for 1 min (detection current: 10 mA)
4,000 Vrms for 1 min (detection current: 10 mA)
Ambient temperature: –40 to +70°C
Humidity: 5 to 85% R.H.
(Not freezing and condensing at low temperature)
[Between input and output]
6 mm
Carton
50
500
Max. 70% V of rated coil voltage (Initial)
Min. 10% V of rated coil voltage (Initial)
8.3 mA
2,880 Ω
130% V of rated coil voltage
Max. 30 mΩ (by voltage drop 6 V DC 1 A)
8 A 250 V AC, 8 A 30 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
10,000 V
Max. 10 ms at rated coil voltage (without bounce)
98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs)
Max. 8 ms at rated coil voltage (without bounce, without diode)
980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 1.5 mm, detection time: 10 µs)
10 to 55 Hz (at double amplitude of 3 mm)
Approx. 6 g
Ambient temperature: -40 to +70°C
Humidity: 5 to 85% RH (Avoid icing and condensation)
[switching frequency: 20 times/min]
Min. 100x103 ope. 8 A 250 V AC
Min. 100x103 ope. 8 A 30 V DC
4,000 Vrms for 1 min
2,000 VA, 240 W
Single side stable
6 V DC
1 Form A 1 Form B
Sockets are available.
Sealed
PC board terminal
200 mW
70%V or less of rated coil voltage (Initial)
10%V or more of rated coil voltage (Initial)
250 V AC, 125 V DC (0.2 A)
8 A (AC, DC)
10 mA 5 V DC
Au-flashed AgSnO2 type
Min. 50x106 ope. (switching frequency: at 300 times/min)
Min. 1x105
1,000 Vrms for 1 min (detection current: 10 mA)
4,000 Vrms for 1 min (detection current: 10 mA)
Ambient temperature: –40 to +70°C
Humidity: 5 to 85% R.H.
(Not freezing and condensing at low temperature)
[Between input and output]
6 mm
Carton
50
500
Max. 70% V of rated coil voltage (Initial)
Min. 10% V of rated coil voltage (Initial)
33.3 mA
180 Ω
130% V of rated coil voltage
Max. 30 mΩ (by voltage drop 6 V DC 1 A)
8 A 250 V AC, 8 A 30 V DC
Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
10,000 V
Max. 10 ms at rated coil voltage (without bounce)
98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs)
Max. 8 ms at rated coil voltage (without bounce, without diode)
980 m/s2 (half-sine shock pulse: 6 ms)
10 to 55 Hz (at double amplitude of 1.5 mm, detection time: 10 µs)
10 to 55 Hz (at double amplitude of 3 mm)
Approx. 6 g
Ambient temperature: -40 to +70°C
Humidity: 5 to 85% RH (Avoid icing and condensation)
[switching frequency: 20 times/min]
Min. 100x103 ope. 8 A 250 V AC
Min. 100x103 ope. 8 A 30 V DC
4,000 Vrms for 1 min
2,000 VA, 240 W