Specification

Specifications table for model ADJH21012
ItemPerformance characteristics
Operating Function 1 coil latching
Type ClassificationStandard type (Without manual switch)
Rated Coil Voltage12 V DC
Protective ConstructionFlux-resistant
Terminal TypePC board terminal
Packing Quantity; Inner Carton (Pcs.) 50
Packing Quantity; Outer Carton (Pcs.)200
Set Voltage Max. 75% V of rated coil voltage (Initial)
Reset VoltageMax. 75% V of rated coil voltage (Initial)
Rated Operating Current [±10%] (at 20°C)Set coil: 83.3 mA
Reset coil: 83.3 mA
Resistance [±10%] (at 20°C) Set coil: 144 Ω
Reset coil: 144 Ω
Rated Operating Power 1,000 mW
Max. Allowable Voltage (at 20°C 68°F)130% V of rated coil voltage
Contact Arrangement1 Form A
Contact ShapeSingle
Contact Resistance (Initial)Max. 20 mΩ (by voltage drop 24 V DC 1 A)
Contact MaterialAgSnO2 type
Contact Rating (Resistive Load)50 A 277 V AC
Max. Switching Power (Resistive Load) 13,850 VA (50 A 277 V AC)
Max. Switching Voltage480 V AC
Max. Switching Current50 A (AC)
Min. Switching Load (Reference Value) 100 mA 5 V DC
Insulation Resistance (Initial)Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.)
Dielectric Strength (Initial): Between Open Contacts1,500 Vrms for 1 min (detection current: 10 mA)
Dielectric Strength (Initial): Between Contact and Coil4,000 Vrms for 1 min (detection current: 10 mA)
Surge Withstand Voltage (Initial): Between Contact and Coil12,000 V
Time (Initial) (at 20°C 68°F) (Initial) Max. 20 ms at rated coil voltage (without bounce)
Reset Time (Initial) (at20°C 68°F) Max. 20 ms at rated coil voltage (without bounce)
Hock Resistance (Functional)100 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs)
Hock Resistance (Destructive)1,000 m/s2 (half-sine shock pulse: 6 ms)
Vibration Resistance (Functional)10 to 55 Hz (at double amplitude of 1.5 mm, detection time: 10 µs)
Vibration Resistance (Destructive)10 to 55 Hz (at double amplitude of 2 mm)
Mechanical LifeMin. 106 ope. (switching frequency: at 180 times/min)
ConditionsAmbient temperature: -40 to +85°C (Allowable temperature is from -40 to +70°C at our standard packing condition.)
Humidity: 5 to 85% RH (Avoid icing and condensation)
Weight (Typ.)Approx. 31 g
Resistive Load[switching frequency ON : OFF = 1 s : 9 s]
Min. 100x103 ope. 25 A 277 V AC
Min. 10x103 ope. 50 A 277 V AC
Inrush Load; Tungsten[switching frequency ON : OFF = 1 s : 59 s]
Min. 25x103 ope. 2,400 W 120 V AC
Inrush Load; Electronic Ballast [switching frequency ON : OFF = 1 s : 9 s]
Min. 6x103 ope. 20 A 277 V AC
Inrush Load; Capacitive (IEC 60669-1)[switching frequency ON : OFF = 1 s : 9 s]
Min. 30x103 ope. 20 A 250 V AC 200 µF