| | EMC Directive, RoHS Directive | Maximum of 16 units per SC-GU3-01 unit (Max. 12 units when FX-500 / LS-500 series are connected)
(Max. 12 units when FX-500 / LS-500 series are connected) | 24V DC +10/-15% Ripple P-P 10 % or less | 120 mA or less (without connected sensor amplifiers) | Wire-saving connector 2 A (Note 1), supply connector 6 A (Note 2) (Note 1) Be sure to check that total current consumption of sensor amplifiers connected in cascade does not exceed allowable passing current. (Note 2) In case of supplying power to other devices, be sure to set the current less than allowable passing current. | CC-Link Ver.1.10 | Switchable 1 or 4 station | 10Mbps / 100m 328.084 ft 5Mbps / 150m 492.126 ft 2.5Mbps / 200m 656.168 ft 625kbps / 600m 1968.504 ft 156kbps / 1,200m 3937.008 ft | | | Specified cable (twist pair cable with shield) (Note) Use only a special-use communication cable that is approved by the CC-Link Partner Association. | 1 to 64 (0 and 65 or more: Error) | Remote device station | | | | | | | –10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed),
(If 4 to 7 units are connected in cascade: –10 to +50 ℃ +14 to +122 ℉,
if 8 to 16 units are connected in cascade: –10 to +45 ℃ +14 to +113 ℉)
Storage: –20 to +70 ℃ –4 to +158 ℉ | 35 to 85 % RH, Storage: 35 to 85 % RH | Enclosure: Polycarbonate | Net weight: 80 g approx. Gross weight: 120 g approx. | | | | | | | | | |
| | EMC Directive, RoHS Directive | Maximum of 16 units per SC-GU3-01 unit (Max. 12 units when FX-500 / LS-500 series are connected) | 24 V DC plus or minus 10 % Ripple P-P 10 % or less | 80 mA or less (at 24 V) (without connected sensor amplifiers) | Wire-saving connector 2 A (Note) Be sure to check that total current consumption of sensor amplifiers connected in cascade does not exceed allowable passing current. | | | | IEEE802.3u | 100 Mbps | Category 5e | | | | | 100 m 328.1ft | RJ45 × 2 | Process data communication, Mailbox communication | | –10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed),
(If 4 to 7 units are connected in cascade: –10 to +50 ℃ +14 to +122 ℉,
if 8 to 16 units are connected in cascade: –10 to +45 ℃ +14 to +113 ℉)
Storage: –20 to +70 ℃ –4 to +158 ℉ | 35 to 85 % RH, Storage: 35 to 85 % RH | Enclosure: Polycarbonate | Net weight: 75 g approx. Gross weight: 120 g approx. | | | | | | | | | |
| | | 1 unit for 1 communication unit | 11 to 25 V DC Ripple P-P 10 % or less | 25 mA or less | | | | | | | | | | | | | | | Green LED (lights up when the power is ON) | –10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), (If 4 to 7 units are connected in cascade: –10 to +50 ℃ +14 to +122 ℉, if 8 to 16 units are connected in cascade: –10 to +45 ℃ +14 to +113 ℉) Storage: –20 to +70 ℃ –4 to +158 ℉ | 35 to 85 % RH, Storage: 35 to 85 % RH | Enclosure: Polycarbonate | Net weight: 20 g approx. Gross weight: 20 g approx. | | | | | | | | | |
| | EMC Directive, RoHS Directive | Maximum of 16 units per SC-GU3-02 unit (Max. 12 units when FX-500 / LS-500 series are connected)
(Max. 12 units when FX-500 / LS-500 series are connected) | 11 to 25 V DC Ripple P-P 10 % or less | 100 mA or less (without connected sensor amplifiers) | Wire-saving connector 2A (Note) Be sure to check that total current consumption of sensor amplifiers connected in cascade does not exceed allowable passing current. | DeviceNet compliant | | 500kbps / 100m 328.084 ft (thick cable) 100m 328.084 ft (thin cable) 250kbps / 250m 820.21 ft (thick cable) 100m 328.084 ft (thin cable) 125kbps / 500m 1640.42 ft (thick cable) 100m 328.084 ft (thin cable) | | | Complies with DeviceNet standards (Note) Use a special cable for DeviceNet that complies with the DeviceNet standards. | | | 0 to 63 (64 or more: Error) | I/O communication (Poll), Explicit message communication | | | | | –10 to +55 ℃ +14 to +131 ℉ (No dew ondensation or icing allowed),
(If 4 to 7 units are connected in cascade: –10 to +50 ℃ +14 to +122 ℉,
if 8 to 16 units are connected in cascade: –10 to +45 ℃ +14 to +113 ℉)
Storage: –20 to +70 ℃ –4 to +158 ℉ | 35 to 85 % RH, Storage: 35 to 85 % RH | Enclosure: Polycarbonate | Net weight: 75 g approx. Gross weight: 120 g approx. | | | | | | | | | |
| | | | 24 V DC +10-15 % Ripple P-P 10 % or less | 200 mA or less (without connected sensor amplifiers) | | CC-Link IE Field | | | | | | 1 to 120 (decimal) (0 and 121 or higher result in an error) | Remote device station | | | | | | | –10 to +50 ℃ +14 to +122 ℉ (8 to 16 units connected: –10 to +45 ℃ +14 to +113 ℉) (No dew condensation or icing allowed)Storage: –20 to +70 ℃ –4 to +158 ℉ | 35 to 85 % RH, Storage: 35 to 85 % RH | Enclosure: Polycarbonate | | EMC Directive(Note), RoHS Directive(Note:Ground the shield wire of the Ethernet cable at a higher-level device in order to comply with the EMC Directive. This product is not provided with a grounding terminal.) | Sensor amplifiers (NPN output type) that can connect to the SC‑71 cascading connector unit (optional) | Maximum of 16 units per SC-GU3-04 unit(Max. 12 units when FX-500 / LS-500 series are connected) | 1 to 239 (decimal) [1 to EF (hex)] (0 and 240 or higher result in an error) (Note:For the Network No. setting of this product, set a value converted to hexadecimal.) | 1 Gbps | 100 m 328.084 ft | 2A or less (Note:Be sure to check that total current consumption of sensor amplifiers connected in cascade does not exceed allowable passing current.) | Line, star (mixing of line and star types is possible), ring | 100 g approx. |
| | | Max. 16 units per 1 communication unit | | | | | | | | | | | | | | | | | | -10 to +55degrees +14 to +131degrees Fahrenheit (If 4 to 7 units are connected in cascade: -10 to +50degrees +14 to +122degrees Fahrenheit , if 8 to 16 units are connected in cascade: -10 to +45degrees +14 to +113degrees Fahrenheit ) (No dew condensation or icing allowed), Storage: -20 to +70degrees - 4 to +158degrees Fahrenheit | 35 to 85 % RH, Storage: 35 to 85 % RH | Enclosure: Polycarbonate Metal plate: Aluminum | Net weight: 10 g approx. Gross weight: 25 g approx. | | | | | | | | | |