Contact-Type Digital Displacement Sensor HG-S

HG-S Series Contact-Type Digital Displacement Sensor

Introducing the New Contact-Type Digital Displacement Sensor featuring the optical absolute method in the slim and strong unit body.  Developed to meet the needs of the production floor, this high-precision, slim Sensor unit features a robust sensor head, while the controller offers a diversity of functions.

Features:

  • Slim body measuring 0.433 x 0.709 x 3.327 inches for easy installation even in a side-by-side arrangement
  • Class-top robustness in the industry
  • High accuracy in Class
  • Resolution of 0.1 μm 0.004 mil and indication accuracy of 1 μm 0.039 mil or less
  • Absolute value scale reading for elimination of “value skipping” and “unset zero point”

 

Part Number List

Results 15
Models table for series Contact-Type Digital Displacement Sensor HG-S
Part No.DatasheetCE Marking Directive ComplianceApplicable ControllerPosition Detection Method Measuring RangeTravel (mm)Measuring Force: Downward MountMeasuring Force: Upward MountMeasuring Force: Side Mount ResolutionSampling RateIndication Accuracy (P-P)Tip Deviation AmountHot Swap FunctionOperation Indicator Environmental Resistance: ProtectionEnvironmental Resistance: Ambient TemperatureEnvironmental Resistance: Ambient HumidityInsulation ResistanceEnvironmental Resistance: Vibration ResistanceEnvironmental Resistance: Shock ResistanceMounting Nut Tightening StrengthProbe Tightening Torque Grounding MethodMaterialWeight (Typ.)AccessoryRemark.Compatible Sensor HeadSupply Voltage Number of Connectable UnitsCurrent ConsumptionAnalog Current OutputControl Outputs (Output 1, Output 2, Output 3)Control Outputs (Output 1, Output 2, Output 3): Short-Circuit ProtectionControl Outputs (Output 1, Output 2, Output 3): Judgment OutputControl Outputs (Output 1, Output 2, Output 3): Alarm Output External Inputs (Input 1, Input 2, Input 3)External Inputs (Input 1, Input 2, Input 3): Trigger InputExternal Inputs (Input 1, Input 2, Input 3): Preset InputExternal Inputs (Input 1, Input 2, Input 3): Reset InputExternal Inputs (Input 1, Input 2, Input 3) Bank Input A/BResponse TimeDigital DisplayDisplay ResolutionDisplay RangeContamination LevelElevationEnvironmental Resistance: Voltage WithstandabilityCableNotesMeasuring forceWorking pressure rangeCapacity to resist pressureUsable fluidApplicable tubePollution Degree Operating Altitude
CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations)
IP40 (IEC)
-10 to +50 ℃ +14 to +122 ℉ (No condensation or icing), Storage: -20 to +60 ℃ -4 to +140 ℉
35 to 85 % RH, Storage: 35 to 85 % RH
20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude (10 to 58Hz), maximum acceleration 49 m/s2 (58 to 150 Hz) in X, Y and Z directions for two hours each
98 m/s2 acceleration (10 G approx.) in X, Y and Z directions five times each
Case: Polycarbonate, Cover: Polycarbonate, Switches: Polyacetal
Net weight:
60 g approx.
Where measurement conditions have not been specified precisely, the conditions used were as follows: supply voltage 24 V DC, ambient temperature +20 ℃ +68 ℉.
HG-S1010-AC,HG-S1110-AC,HG-S1010(R),HG-S1110(R),HG-S1032,HG-S1050
24 V DC ±10 %, including ripple 0.5 V (P-P)
Up to 15 slave units can be connected per master unit. (Note):When connected to a communication unit for digital displacement sensor, up to 14 slave units can be connected per master unit.
70 mA or less (when sensor head is connected)(Note):Current consumption does not include analog current output.
-
-
-
-
-
-
-
-
-
-
3 ms, 5 ms, 10 ms, 100 ms, 500 ms, 1,000 ms switching type
204-segment LCD
0.1μm 0.004 mil
-199.9999 to 199.9999mm -7.874 to 7.874 in
2
2,000 m 6561.68 ft or less (Note):Do not use or store in an environment that has been pressurized to an air pressure higher than the atmospheric pressure at 0 m.
1,000 V AC for one min. between all supply terminals connected together and enclosure
-
Where measurement conditions have not been specified precisely, the conditions used were as follows: supply voltage 24 V DC, ambient temperature +20℃ +68℉.
2
2000 m 6561.68 ft or less
CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations)
IP40 (IEC)
-10 to +50 ℃ +14 to +122 ℉ (No condensation or icing), Storage: -20 to +60 ℃ -4 to +140 ℉
35 to 85 % RH, Storage: 35 to 85 % RH
20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude (10 to 58Hz), maximum acceleration 49 m/s2 (58 to 150 Hz) in X, Y and Z directions for two hours each
98 m/s2 acceleration (10 G approx.) in X, Y and Z directions five times each
Case: Polycarbonate, Cover: Polycarbonate, Switches: Polyacetal
Net weight:
130 g approx.
Where measurement conditions have not been specified precisely, the conditions used were as follows: supply voltage 24 V DC, ambient temperature +20 ℃ +68 ℉.
HG-S1010-AC,HG-S1110-AC,HG-S1010(R),HG-S1110(R),HG-S1032,HG-S1050
24 V DC ±10 %, including ripple 0.5 V (P-P)
Up to 15 slave units can be connected per master unit. (Note):When connected to a communication unit for digital displacement sensor, up to 14 slave units can be connected per master unit.
70 mA or less (when sensor head is connected)(Note):Current consumption does not include analog current output.
-

NPN open-collector transistor
• Maximum sink current: 50 mA(Note 5))
• Applied voltage: 30 V DC or less(between output and 0 V)
• Residual voltage: 1.5 V or less(at 50 mA sink current)
• Leakage current: 0.1 mA or less

>
PNP open-collector transistor
• Maximum source current: 50 mA(Note 5)
• Applied voltage: 30 V DC or less(between output and +V)
• Residual voltage: 1.5 V or less(at 50 mA source current)
• Leakage current: 0.1 mA or less
Incorporated (automatic reset type)
NO / NC switching method
Open when alarm occurs

Non-contact input or NPN open-collector transistor
• Input condition:
Invalid (+8 V to +V DC or open)
Valid (0 to +1.2 V DC)
•Input impedance: 10 kΩ approx.


Non-contact input or PNP open-collector transistor
• Input condition:
Invalid (0 to +0.6 V DC or open)
Valid (+4 V to +V DC)
• Input impedance: 10 kΩ approx.
Input time 2 ms or more (ON)
Input time 20 ms or more (ON)
Input time 20 ms or more (ON)
Input time 20 ms or more (ON)(Note):Banks 1 to 3 can be selected by switching bank input A / B.
3 ms, 5 ms, 10 ms, 100 ms, 500 ms, 1,000 ms switching type
204-segment LCD
0.1μm 0.004 mil
-199.9999 to 199.9999mm -7.874 to 7.874 in
2
2,000 m 6561.68 ft or less (Note):Do not use or store in an environment that has been pressurized to an air pressure higher than the atmospheric pressure at 0 m.
1,000 V AC for one min. between all supply terminals connected together and enclosure
0.15 mm2, 6‑core composite cable, 2 m 6.562 ft long
Where measurement conditions have not been specified precisely, the conditions used were as follows: supply voltage 24 V DC, ambient temperature +20℃ +68℉.
2
2000 m 6561.68 ft or less
CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations)
IP40 (IEC)
-10 to +50 ℃ +14 to +122 ℉ (No condensation or icing), Storage: -20 to +60 ℃ -4 to +140 ℉
35 to 85 % RH, Storage: 35 to 85 % RH
20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude (10 to 58Hz), maximum acceleration 49 m/s2 (58 to 150 Hz) in X, Y and Z directions for two hours each
98 m/s2 acceleration (10 G approx.) in X, Y and Z directions five times each
Case: Polycarbonate, Cover: Polycarbonate, Switches: Polyacetal
Net weight:
140 g approx.
Where measurement conditions have not been specified precisely, the conditions used were as follows: supply voltage 24 V DC, ambient temperature +20 ℃ +68 ℉.
HG-S1010-AC,HG-S1110-AC,HG-S1010(R),HG-S1110(R),HG-S1032,HG-S1050
24 V DC ±10 %, including ripple 0.5 V (P-P)
Up to 15 slave units can be connected per master unit. (Note):When connected to a communication unit for digital displacement sensor, up to 14 slave units can be connected per master unit.
70 mA or less (when sensor head is connected)(Note):Current consumption does not include analog current output.
• Current output range:4 to 20 mA/F.S.(default value)
• Error output:0 mA
• Linearity:±0.25% F.S.
• Load impedance:250Ω max.

NPN open-collector transistor
• Maximum sink current: 50 mA(Note 5))
• Applied voltage: 30 V DC or less(between output and 0 V)
• Residual voltage: 1.5 V or less(at 50 mA sink current)
• Leakage current: 0.1 mA or less

>
PNP open-collector transistor
• Maximum source current: 50 mA(Note 5)
• Applied voltage: 30 V DC or less(between output and +V)
• Residual voltage: 1.5 V or less(at 50 mA source current)
• Leakage current: 0.1 mA or less
Incorporated (automatic reset type)
NO / NC switching method
Open when alarm occurs

Non-contact input or NPN open-collector transistor
• Input condition:
Invalid (+8 V to +V DC or open)
Valid (0 to +1.2 V DC)
•Input impedance: 10 kΩ approx.


Non-contact input or PNP open-collector transistor
• Input condition:
Invalid (0 to +0.6 V DC or open)
Valid (+4 V to +V DC)
• Input impedance: 10 kΩ approx.
Input time 2 ms or more (ON)
Input time 20 ms or more (ON)
Input time 20 ms or more (ON)
Input time 20 ms or more (ON)(Note):Banks 1 to 3 can be selected by switching bank input A / B.
3 ms, 5 ms, 10 ms, 100 ms, 500 ms, 1,000 ms switching type
204-segment LCD
0.1μm 0.004 mil
-199.9999 to 199.9999mm -7.874 to 7.874 in
2
2,000 m 6561.68 ft or less (Note):Do not use or store in an environment that has been pressurized to an air pressure higher than the atmospheric pressure at 0 m.
1,000 V AC for one min. between all supply terminals connected together and enclosure
0.2 mm2 2-core cable (brown and blue lead wires) / 0.15 mm2 7‑core composite cable, 2 m 6.562 ft long
Where measurement conditions have not been specified precisely, the conditions used were as follows: supply voltage 24 V DC, ambient temperature +20℃ +68℉.
2
2000 m 6561.68 ft or less
CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations)
IP40 (IEC)
-10 to +50 ℃ +14 to +122 ℉ (No condensation or icing), Storage: -20 to +60 ℃ -4 to +140 ℉
35 to 85 % RH, Storage: 35 to 85 % RH
20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude (10 to 58Hz), maximum acceleration 49 m/s2 (58 to 150 Hz) in X, Y and Z directions for two hours each
98 m/s2 acceleration (10 G approx.) in X, Y and Z directions five times each
Case: Polycarbonate, Cover: Polycarbonate, Switches: Polyacetal
Net weight:
130 g approx.
Where measurement conditions have not been specified precisely, the conditions used were as follows: supply voltage 24 V DC, ambient temperature +20 ℃ +68 ℉.
HG-S1010-AC,HG-S1110-AC,HG-S1010(R),HG-S1110(R),HG-S1032,HG-S1050
24 V DC ±10 %, including ripple 0.5 V (P-P)
Up to 15 slave units can be connected per master unit. (Note):When connected to a communication unit for digital displacement sensor, up to 14 slave units can be connected per master unit.
70 mA or less (when sensor head is connected)(Note):Current consumption does not include analog current output.
-

NPN open-collector transistor
• Maximum sink current: 50 mA(Note 5))
• Applied voltage: 30 V DC or less(between output and 0 V)
• Residual voltage: 1.5 V or less(at 50 mA sink current)
• Leakage current: 0.1 mA or less

>
PNP open-collector transistor
• Maximum source current: 50 mA(Note 5)
• Applied voltage: 30 V DC or less(between output and +V)
• Residual voltage: 1.5 V or less(at 50 mA source current)
• Leakage current: 0.1 mA or less
Incorporated (automatic reset type)
NO / NC switching method
Open when alarm occurs

Non-contact input or NPN open-collector transistor
• Input condition:
Invalid (+8 V to +V DC or open)
Valid (0 to +1.2 V DC)
•Input impedance: 10 kΩ approx.


Non-contact input or PNP open-collector transistor
• Input condition:
Invalid (0 to +0.6 V DC or open)
Valid (+4 V to +V DC)
• Input impedance: 10 kΩ approx.
Input time 2 ms or more (ON)
Input time 20 ms or more (ON)
Input time 20 ms or more (ON)
Input time 20 ms or more (ON)(Note):Banks 1 to 3 can be selected by switching bank input A / B.
3 ms, 5 ms, 10 ms, 100 ms, 500 ms, 1,000 ms switching type
204-segment LCD
0.1μm 0.004 mil
-199.9999 to 199.9999mm -7.874 to 7.874 in
2
2,000 m 6561.68 ft or less (Note):Do not use or store in an environment that has been pressurized to an air pressure higher than the atmospheric pressure at 0 m.
1,000 V AC for one min. between all supply terminals connected together and enclosure
0.15 mm2, 6‑core composite cable, 2 m 6.562 ft long
Where measurement conditions have not been specified precisely, the conditions used were as follows: supply voltage 24 V DC, ambient temperature +20℃ +68℉.
2
2000 m 6561.68 ft or less
CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations)
HG-SC101(-P), HG-SC111(-P), HG-SC112(-P), HG-SC113
Optical absolute linear encoder method
10 mm 0.394 in
10.5 mm 0.413 in or more
1.65 N or less
1.10 N
(Note): Typical value near center of measurement.
1.35 N or less
0.85 N
(Note): Typical value near center of measurement.
1.50 N or less
0.95 N
(Note): Typical value near center of measurement.
0.5 μm 0.020 mil
1ms
Full range: 2.0 μm 0.079 mil or less
Narrow range: 1.0 μm 0.039 mil or less
(any 60 μm 2.362 mil)
35 μm 1.378 mil (typical)(Note):Linearity F.S. = 16 mA, and is linearity with respect to digitally measured values.
Incorporated
2-color LED (Orange / Green)
IP67 (IEC)
(Note): Excludes damage and deterioration to rubber bellows due to external causes.
-10 to +55 ℃ +14 to +131 ℉
(No condensation or icing),
Storage: -20 to +60 ℃ -4 to +140 ℉
35 to 85 % RH, Storage: 35 to 85 % RH
100 MΩ or more at 250 V DC
10 to 500 Hz frequency, 3 mm 0.118 in double amplitude (maximum acceleration 196 m/s2) in X, Y and Z directions for two hours each
1,960 m/s2acceleration in X, Y and Z directions three times each
12.5N・m
0.1 to 0.4 N・m (no force applied to main unit)
Capacitor grounding
Body: Zinc, Holder: Stainless steel, Spindle: Tool steel, Probe: Brass (body) / Ceramic (ball), Rubber bellows: NBR (black)
※The probes (optional) are also available.
Net weight: 80 g approx.
Standard type (HG-S1010 / HG-S1110): Sensor head fastening wrench 1 pc., Mounting nut 1 pc.
Where measurement conditions have not been specified precisely, the conditions used were as follows: standard type measurement probe (HG-SS10C), ambient temperature +20 ℃ +68 ℉, and a clean atmosphere where dust and liquids such as water and oil do not come in contact with the equipment.
2
2,000 m 6561.68 ft or less
(Note) : Do not use or store in an environment that has been pressurized to an air pressure higher than the atmospheric pressure at 0 m.
CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations)
HG-SC101(-P), HG-SC111(-P), HG-SC112(-P), HG-SC113
Optical absolute linear encoder method
10 mm 0.394 in
10.5 mm 0.413 in or more
0.35 N or less
0.30 N
(Note 1): In the case of low measurement force type (HG-S1010R / HG-S1110R), measurements were obtained with products in standard configuration without rubber bellows.
(Note 2): Typical value near center of measurement.
-
0.25 N or less
0.20 N
(Note 1): In the case of low measurement force type (HG-S1010R / HG-S1110R), measurements were obtained with products in standard configuration without rubber bellows.
(Note 2): Typical value near center of measurement.
0.1 μm 0.004 mil
1ms
Full range: 1.0 μm 0.039 mil or less
Narrow range: 0.5 μm 0.020 mil or less
(any 60 μm 2.362 mil)
35 μm 1.378 mil (typical)(Note):Linearity F.S. = 16 mA, and is linearity with respect to digitally measured values.
Incorporated
2-color LED (Orange / Green)
-
-10 to +55 ℃ +14 to +131 ℉
(No condensation or icing),
Storage: -20 to +60 ℃ -4 to +140 ℉
35 to 85 % RH, Storage: 35 to 85 % RH
100 MΩ or more at 250 V DC
10 to 500 Hz frequency, 3 mm 0.118 in double amplitude (maximum acceleration 196 m/s2) in X, Y and Z directions for two hours each
1,960 m/s2acceleration in X, Y and Z directions three times each
12.5N・m
0.1 to 0.4 N・m (no force applied to main unit)
Capacitor grounding
Body: Zinc, Holder: Stainless steel, Spindle: Tool steel, Probe: Brass (body) / Ceramic (ball), Rubber bellows: NBR (black)
※The probes (optional) are also available.
Net weight: 80 g approx.
Low measuring force type (HG-S1010R / HG-S1110R): Sensor head fastening wrench 1 pc., Mounting nut 1 pc., Rubber bellows 1 pc.
Where measurement conditions have not been specified precisely, the conditions used were as follows: standard type measurement probe (HG-SS10C), ambient temperature +20 ℃ +68 ℉, and a clean atmosphere where dust and liquids such as water and oil do not come in contact with the equipment.
2
2,000 m 6561.68 ft or less
(Note) : Do not use or store in an environment that has been pressurized to an air pressure higher than the atmospheric pressure at 0 m.
CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations)
HG-SC101(-P), HG-SC111(-P), HG-SC112(-P), HG-SC113
(Note) : Be sure to use the sensor in combination with an HG-SC□ controller manufactured in or after February 2019.
Optical absolute linear encoder method
10 mm 0.394 in
(Note) : The position that represents "0" as an absolute value is a position where the spindle is pushed further down from the bottom dead point by 0.1 mm 0.004 in or more. The term "stroke" indicates the total stroke length from the bottom dead point to the top dead point.
10.5 mm 0.413 in or more
(Note) : The position that represents "0" as an absolute value is a position where the spindle is pushed further down from the bottom dead point by 0.1 mm 0.004 in or more. The term "stroke" indicates the total stroke length from the bottom dead point to the top dead point.
0.5 μm 0.02 mil
1 ms
Full range: 2.0 μm 0.079 mil or less
Limited range: 1.0 μm 0.039 mil or less
(any 60 μm 2.362 mil)
35 μm 1.378 mil (typical value)
Incorporated
Equipped (2-color LED: Orange / Green)
IP67 (IEC)
With no seal cap mounted : -
(Note) : Protective structure is not applicable when the sealing portions have deteriorated or become damaged. The protection level is zero when the seal cap is removed.
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed),
Storage: -20 to +60 ℃ -4 to +140 ℉
35 to 85 % RH, Storage: 35 to 85 % RH
100 MΩ or more at 250 V DC
10 to 500 Hz frequency, 3 mm 0.118 in double amplitude (10 to 58 Hz), maximum acceleration 196 m/s2, (58 to 150 Hz) in X, Y, and Z directions for two hours each
1,960 m/s2 acceleration in X, Y, and Z directions three times each
Capacitor grounding
Body: Zinc, Holder: Stainless steel, Spindle: Tool steel, Probe (Note): Brass (body) / Ceramic (ball),, Air tube clamp: S60CM
(Note) : The probe is also available as an option.
Net weight: 80 g approx.
Sensor head fastening wrench: 1 pc., Mounting nut: 1 pc., Seal cap: 1pc, Air tube clamp: 1 pc.
Where measurement conditions are not specified, the conditions used were as follows: standard type measurement probe (HG-SS10C), ambient temperature of +20 ℃ +68 ℉, and a clean atmosphere where water, oil, other liquids or dust does not come in contact with the equipment.
・Measuring force changes with the air pressure used. Removing the seal cap enables the product to be used as the low measuring force type.
・For the relationship between supplied air pressure and measuring force or between measuring force and pushed spindle position, see the figures below. For upward mount without a seal cap, subtract 0.2 N from the measuring force. For side mount, subtract 0.1 N from the measuring force. The following figures are only typical examples, and these relationships differ depending on the assembly accuracy of the product or the abrasion status of sealing materials.
the relationship between supplied air pressure and measuring force or between measuring force and pushed spindle position
0.14 to 0.16 MPa
With no seal cap mounted : 0.035 to 0.045 MPa
0.2 MPa
Clean air (Dew point temperature: -10 ℃ +14 ℉ or less)
Outside diameter: ø4 mm ø0.157 in / Inside diameter: ø2.5 mm ø0.098 in
2
2,000 m 6561.68 ft or less
(Note) : Do not use or store in an environment that has been pressurized to an air pressure higher than the atmospheric pressure at 0 m.
CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations)
HG-SC101(-P), HG-SC111(-P), HG-SC112(-P), HG-SC113
(Note) : Be sure to use the sensor in combination with an HG-SC□ controller manufactured in or after February 2019.
Optical absolute linear encoder method
10 mm 0.394 in
(Note) : The position that represents "0" as an absolute value is a position where the spindle is pushed further down from the bottom dead point by 0.1 mm 0.004 in or more. The term "stroke" indicates the total stroke length from the bottom dead point to the top dead point.
10.5 mm 0.413 in or more
(Note) : The position that represents "0" as an absolute value is a position where the spindle is pushed further down from the bottom dead point by 0.1 mm 0.004 in or more. The term "stroke" indicates the total stroke length from the bottom dead point to the top dead point.
0.1 μm 0.004 mil
1 ms
Full range: 1.0 μm 0.039 mil or less
Limited range: 0.5 μm 0.02 mil or less
(any 60 μm 2.362 mil)
35 μm 1.378 mil (typical value)
Incorporated
Equipped (2-color LED: Orange / Green)
IP67 (IEC)
With no seal cap mounted : -
(Note) : Protective structure is not applicable when the sealing portions have deteriorated or become damaged. The protection level is zero when the seal cap is removed.
-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed),
Storage: -20 to +60 ℃ -4 to +140 ℉
35 to 85 % RH, Storage: 35 to 85 % RH
100 MΩ or more at 250 V DC
10 to 500 Hz frequency, 3 mm 0.118 in double amplitude (10 to 58 Hz), maximum acceleration 196 m/s2, (58 to 150 Hz) in X, Y, and Z directions for two hours each
1,960 m/s2 acceleration in X, Y, and Z directions three times each
Capacitor grounding
Body: Zinc, Holder: Stainless steel, Spindle: Tool steel, Probe (Note): Brass (body) / Ceramic (ball),, Air tube clamp: S60CM
(Note) : The probe is also available as an option.
Net weight: 80 g approx.
Sensor head fastening wrench: 1 pc., Mounting nut: 1 pc., Seal cap: 1pc, Air tube clamp: 1 pc.
Where measurement conditions are not specified, the conditions used were as follows: standard type measurement probe (HG-SS10C), ambient temperature of +20 ℃ +68 ℉, and a clean atmosphere where water, oil, other liquids or dust does not come in contact with the equipment.
・Measuring force changes with the air pressure used. Removing the seal cap enables the product to be used as the low measuring force type.
・For the relationship between supplied air pressure and measuring force or between measuring force and pushed spindle position, see the figures below. For upward mount without a seal cap, subtract 0.2 N from the measuring force. For side mount, subtract 0.1 N from the measuring force. The following figures are only typical examples, and these relationships differ depending on the assembly accuracy of the product or the abrasion status of sealing materials.
the relationship between supplied air pressure and measuring force or between measuring force and pushed spindle position
0.14 to 0.16 MPa
With no seal cap mounted : 0.035 to 0.045 MPa
0.2 MPa
Clean air (Dew point temperature: -10 ℃ +14 ℉ or less)
Outside diameter: ø4 mm ø0.157 in / Inside diameter: ø2.5 mm ø0.098 in
2
2,000 m 6561.68 ft or less
(Note) : Do not use or store in an environment that has been pressurized to an air pressure higher than the atmospheric pressure at 0 m.
CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations)
IP40 (IEC)
-10 to +50 ℃ +14 to +122 ℉ (No condensation or icing), Storage: -20 to +60 ℃ -4 to +140 ℉
35 to 85 % RH, Storage: 35 to 85 % RH
20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude (10 to 58Hz), maximum acceleration 49 m/s2 (58 to 150 Hz) in X, Y and Z directions for two hours each
98 m/s2 acceleration (10 G approx.) in X, Y and Z directions five times each
Case: Polycarbonate, Cover: Polycarbonate, Switches: Polyacetal
Net weight:
140 g approx.
Where measurement conditions have not been specified precisely, the conditions used were as follows: supply voltage 24 V DC, ambient temperature +20 ℃ +68 ℉.
HG-S1010-AC,HG-S1110-AC,HG-S1010(R),HG-S1110(R),HG-S1032,HG-S1050
24 V DC ±10 %, including ripple 0.5 V (P-P)
Up to 15 slave units can be connected per master unit. (Note):When connected to a communication unit for digital displacement sensor, up to 14 slave units can be connected per master unit.
70 mA or less (when sensor head is connected)(Note):Current consumption does not include analog current output.
• Current output range:4 to 20 mA/F.S.(default value)
• Error output:0 mA
• Linearity:±0.25% F.S.
• Load impedance:250Ω max.

NPN open-collector transistor
• Maximum sink current: 50 mA(Note 5))
• Applied voltage: 30 V DC or less(between output and 0 V)
• Residual voltage: 1.5 V or less(at 50 mA sink current)
• Leakage current: 0.1 mA or less

>
PNP open-collector transistor
• Maximum source current: 50 mA(Note 5)
• Applied voltage: 30 V DC or less(between output and +V)
• Residual voltage: 1.5 V or less(at 50 mA source current)
• Leakage current: 0.1 mA or less
Incorporated (automatic reset type)
NO / NC switching method
Open when alarm occurs

Non-contact input or NPN open-collector transistor
• Input condition:
Invalid (+8 V to +V DC or open)
Valid (0 to +1.2 V DC)
•Input impedance: 10 kΩ approx.


Non-contact input or PNP open-collector transistor
• Input condition:
Invalid (0 to +0.6 V DC or open)
Valid (+4 V to +V DC)
• Input impedance: 10 kΩ approx.
Input time 2 ms or more (ON)
Input time 20 ms or more (ON)
Input time 20 ms or more (ON)
Input time 20 ms or more (ON)(Note):Banks 1 to 3 can be selected by switching bank input A / B.
3 ms, 5 ms, 10 ms, 100 ms, 500 ms, 1,000 ms switching type
204-segment LCD
0.1μm 0.004 mil
-199.9999 to 199.9999mm -7.874 to 7.874 in
2
2,000 m 6561.68 ft or less (Note):Do not use or store in an environment that has been pressurized to an air pressure higher than the atmospheric pressure at 0 m.
1,000 V AC for one min. between all supply terminals connected together and enclosure
0.15 mm2, 7‑core composite cable, 2 m 6.562 ft long
Where measurement conditions have not been specified precisely, the conditions used were as follows: supply voltage 24 V DC, ambient temperature +20℃ +68℉.
2
2000 m 6561.68 ft or less